Norgen’s EXTRAClean RNA Clean-Up and Concentration Micro-Elution Kit provides a rapid method for the purification, cleanup and concentration of up to 10 μg of RNA isolated using different methods including phenol/guanidine-based protocols, and from various upstream enzymatic reactions such as DNase treatment, labeling and in vitro transcription. The minimum recommended elution volume is 8 μL, which enables the concentration of small amounts of all sizes of RNA, from large mRNA and ribosomal RNA down to microRNA (miRNA) and small interfering RNA (siRNA). The RNA is preferentially purified from other reaction components such as proteins, RNases and nucleotides, without the use of phenol or chloroform. The EXTRAClean columns undergo stringent processing and rigorous quality control measures to minimize contamination traces, ensuring optimal results for sensitive applications such as NGS. The purified RNA is of the highest integrity, and can be used in a number of downstream applications including end-point or quantitative reverse transcription PCR, Northern blotting, RNase protection and primer extension, expression array assays and next generation sequencing.
Kit Specifications (Spin Column) | |
Maximum Column Binding Capacity | 10 μg |
Size of RNA Purified | All sizes, including miRNA and small RNA (< 200 nt) |
Maximum Amount of Starting Material | 10 μg of RNA |
Minimum Elution Volume | 8 μL |
Time to Complete 10 Purifications | 20 minutes |
Average Yields | ≥ 90% |
Hepatitis C virus infection is a major cause of chronic hepatitis, liver cirrhosis, and hepatocellular carcinoma (HCC) worldwide. Neither a vaccine nor an effective treatment is available for HCV. Pegylated interferon-α (PEG-IFN- α), combined with ribavirin, is the current standard therapy. Its efficiency ranges between 20-80%, depending on the HCV genotype. Unfortunately, many HCV infected patients do not respond to or do not tolerate the IFN-based therapy. Therefore, the number of patients progressing to HCC, as a result of HCV infection, is expected to increase over the next 20-30 years. The natural history of the disease reveals the elusive nature of the virus in a number of features. First, the infection is often detected incidentally at the time of blood donation as the acute infection is clinically asymptomatic in most patients. Second, HCV successfully escapes multi-specific host immune responses in the majority of patients which establishes persistent infection. Third, a significant number of persistently infected individuals remain unaware of the infection for decades, until liver fibrosis, cirrhosis and/or hepatocellular carcinoma develop.
HCV TaqMan RT-PCR Kit, 100 reactions
HCV TaqMan RT-PCR Probe/Primer Set and Controls, 100 reactions
For research use only and NOT intended for in vitro diagnostics.
Figure 1 / 3
Click for expanded view
Storage Conditions and Product Stability
All kit components can be stored for 1 year after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival.
Component | Cat. TM37650 (100 preps) | Cat. TM37610 (100 preps) |
---|---|---|
MDx TaqMan 2X PCR Master Mix | 2 x 700 μL | – |
HCV Primer & Probe Mix | 280 μL | 280 μL |
HCV Positive Control | 150 μL | 150 μL |
Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL |
Product Insert | 1 | 1 |