Optically clear flat bottom plates with detachable wells allow for direct microscopic viewing and can be used with top and bottom reading instruments. Detachable wells give the user improved flexibility. Individual alphanumerical codes for easy identification. Minimum volume of 50uL maximum of 300.
Other Products
MINI-3 Microplate Centrifuge
Product Info
Document
Product Info
Product advantages
1. The instantaneous centrifugal function rises to the maximum speed for about 6 seconds, allowing for rapid detachment of hanging droplets from the wall;
2. Faster acceleration and deceleration rate, required to complete the experiment in a shorter time;
3. Door cover protection, overspeed and imbalance detection system, capable of real-time monitoring of the centrifugal process, ensuring the safe operation of the instrument; When the operation ends, an error occurs, or an imbalance occurs, the sound signal prompts, and the operation stops at the same time. The LCD displays the result code
Host Parameters
Product model
Mini-3
Input power supply
DC24V/2.75A
Input power
55W
Motor/Drive Method
DC24V brushless DC variable frequency motor
Display method
High brightness LCD screen
Effective centrifugal time
1-99min.1-59sec
speed
300~3000±15rpm
Speed step increase
10rpm
Maximum capacity
2 *96 well PCR plates/ELISA plates
MAX. RCF
608 xg
Misoperation/alarm failure
Sound prompt+display code
weight
3.9Kg
Noise
60dB (A)
Fastest acceleration time
<6s
Fastest deceleration time
<5s
Permissible ambient temperature/relative temperature
+5-40°C/80%
Document
The micro porous plate centrifuge adopts international advanced design concepts and manufacturing technology, with a smooth and beautiful appearance, compact and stable structure, adhering to the advantages of high universality and easy operation. It also has the functional characteristics of “smooth start” and “smooth braking”; This micro porous plate centrifuge is very suitable for 96 or 384 well and small capacity micro porous plates, as well as various standard PCR micro porous plates with or without skirts .
Hydroxy-PEG3-DBCO is a PEG linker containing a DBCO moiety and a terminal primary hydroxyl group. The hydroxyl can react with a variety of functional groups and the hydrophilic PEG spacer arm can provide better solubility to labeled molecules. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Document
Hydroxy-PEG3-DBCO is a PEG linker containing a DBCO moiety and a terminal primary hydroxyl group. The hydroxyl can react with a variety of functional groups and the hydrophilic PEG spacer arm can provide better solubility to labeled molecules. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
Phosphate
Assay Format:
Spectrophotometer, Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
360
Signal Response:
Increase
Linear Range:
0.1 to 10 μg of phosphate per assay
Limit of Detection:
0.16 mg/L
Reaction Time (min):
~ 20 min
Application examples:
Processed foods and drinks, bakery products, dairy products, waste water samples, cosmetics, pharmaceuticals and other materials (e.g. biological cultures, etc.).
The Phosphate Assay Kit is a rapid, simple, reliable and accurate method for the specific measurement and analysis of phosphate in water, foodstuffs, beverages and other materials. The phosphate detection reaction employs the defined chemical substrate 2-amino-6-mercapto-7-methylpurine ribonucleoside (MESG). In the presence of phosphate, the substrate is converted enzymatically by purine nucleoside phosphorylase (PNPase) to the products ribose 1-phosphate and 2-amino-6-mercapto-7-methylpurine. An application note describes the dephosphorylation reaction of phytic acid using phytase and alkaline phosphatase (sold separately), and subsequent phosphate detection using the reagents provided in K-PHOS.
This method is suitable for analysis using spectrophotometer and auto-analyser.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved.
Need other products? See our complete list of assay kits.
Advantages
Chemically defined detection method
All reagents stable for > 2 years after preparation
Rapid reaction (~ 20 min)
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual and auto-analyser formats
Document
The Phosphate Assay Kit is a rapid, simple, reliable and accurate method for the specific measurement and analysis of phosphate in water, foodstuffs, beverages and other materials. The phosphate detection reaction employs the defined chemical substrate 2-amino-6-mercapto-7-methylpurine ribonucleoside (MESG). In the presence of phosphate, the substrate is converted enzymatically by purine nucleoside phosphorylase (PNPase) to the products ribose 1-phosphate and 2-amino-6-mercapto-7-methylpurine. An application note describes the dephosphorylation reaction of phytic acid using phytase and alkaline phosphatase (sold separately), and subsequent phosphate detection using the reagents provided in K-PHOS.