Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
Citric Acid
Assay Format:
Spectrophotometer, Microplate, Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Decrease
Linear Range:
1.0 to 100 µg of citric acid per assay
Limit of Detection:
0.491 mg/L
Reaction Time (min):
~ 5 min
Application examples:
Grape juice, wine, beer, fruit juices, soft drinks, tea, dairy products (e.g. cheese), meat, processed meat, vegetable and fruit products, bakery products, paper, pharmaceuticals, cosmetics and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Methods based on this principle have been accepted by MEBAK, OIV, EU, ISO2963, AOAC and IFU22 (NOTE: If the enzyme oxaloacetate decarboxylase is present in the sample, some of the oxaloacetate product is converted to pyruvate. Therefore, to ensure citric acid is measured quantitatively, D-lactate dehydrogenase (D-LDH) is employed to efficiently convert any pyruvate produced into D-lactate and NAD+).
The Citric Acid test kit is a flexible and simple method for the rapid and reliable measurement and analysis of citric acid (citrate) in foods, beverages and other materials.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
Extended cofactors stability. Dissolved cofactors stable for > 1 year at 4oC.
Reconstituted citrate lyase stable for 4 weeks at 4oC / 6 months below -10oC
Buffer / cofactor / enzyme tablets for efficient use of kit components
PVP incorporated to prevent tannin inhibition
Very competitive price (cost per test)
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual, microplate and auto-analyser formats
Document
The Citric Acid test kit is a flexible and simple method for the rapid and reliable measurement and analysis of citric acid (citrate) in foods, beverages and other materials.
This kit provides a simple and fast solution for the extraction of circulating nuclear acid from serum, plasma, and other cell-free liquid samples. Circulating nucleic acid refers to the free extracellular nucleic acid produced by cell apoptosis, of which fragments are generally below 1KB. The kit is based on silica gel column purification technology, which is no need for toxic phenol chloroform extraction and time-consuming alcohol precipitation during the extraction. The obtained Circulating Nucleic Acid can be directly used for quantitative PCR, liquid or solid phase chip analysis, hybridization, and SNP detection. HiPure Circulating DNA/RNA Kit adopts a unique solution system and multiple layers of filter membranes with different pore sizes, which can efficiently process large volumes of serum and plasma samples and capture extremely small amounts of free nucleic acids.
Details
Specifications
Features
Specifications
Main Functions
Isolation both Circulating DNA/RNA (include miRNA) from 1-5 ml serum and plasma
Applications
qPCR / RT-PCR, liquid or solid-phasechip analysis, hybridization and SNP detection
Purification method
Midi spin column
Purification technology
Silica technology, DNA filtration technology
Process method
Manual (centrifugation or vacuum)
Sample type
serum, plasma, and other cell-free liquid samples
Sample amount
1-5 ml
Elution volume
≥20μl
Time per run
≤100 minutes
Liquid carrying volume per column
4 ml
Binding yield of column
1 mg
Principle
This kit is based on silica gel column technology. Serum or other liquid samples are lysed and digested in buffer CFL. After adding buffer CFP, the protein is removed by centrifugation to obtain the supernatant. Isopropanol is added to precipitate the total nucleic acid and transferred to the column for filtration. DNA / RNA is adsorbed on the membrane of the column, while the protein is not adsorbed and removed with the filtrate.The column is washed with buffer MGW1 to remove protein and other impurities, and then washed with buffer RW2 to remove salt. Finally, DNA / RNA is eluted by low salt buffer. The eluted DNA / RNA can be directly used for quantitative PCR/ RT-PCR, liquid or solid-phase chip analysis, hybridization and SNP detection.
Advantages
High yield – most optimized process to obtain maximum free RNA and small RNA
High concentration – low elution volume (>20μl) to ensure nucleic acid concentration
High purity – low alcohol combination, completely remove inhibitor and protein pollution
High recovery – silica gel column technology can recover nucleic acid molecules at the level of PG
Large volume – 1-2ml serum and plasma samples can be processed at one time
Kit Contents
Contents
R431602
D431603
Purification Times
50 Preps
250 Preps
HiPure RNA Micro Columns
50
5 x 50
HiPure Viral Midi Columns
50
5 x 50
15 ml Collection Tubes
50
5 x 50
2ml Collection Tubes
50
5 x 50
Buffer CFL
150 ml
2 x 375 ml
Buffer CFP
30 ml
150 ml
Buffer MGW1*
100 ml
2 x 250 ml
Buffer RW2*
2 x 50 ml
5 x 100 ml
RNase Free Water
10 ml
50 ml
Storage and Stability
The kit components can be stored at room temperature (15–25°C) and are stable for at least 18 months under these conditions.
Document
This kit provides a simple and fast solution for the extraction of circulating nuclear acid from serum, plasma, and other cell-free liquid samples. Circulating nucleic acid refers to the free extracellular nucleic acid produced by cell apoptosis, of which fragments are generally below 1KB. The kit is based on silica gel column purification technology, which is no need for toxic phenol chloroform extraction and time-consuming alcohol precipitation during the extraction. The obtained Circulating Nucleic Acid can be directly used for quantitative PCR, liquid or solid phase chip analysis, hybridization, and SNP detection. HiPure Circulating DNA/RNA Kit adopts a unique solution system and multiple layers of filter membranes with different pore sizes, which can efficiently process large volumes of serum and plasma samples and capture extremely small amounts of free nucleic acids.
The ITS1 Library Preparation Kit for Illumina consists of the reagents and components required for library preparation of the fungal target ITS1 libraries to be used for next-generation sequencing on Illumina platforms. All molecular reagents including primers, enzyme mixes, indexes, and buffers are provided. Instructions for PCR clean up with the AMPure XPMagneticBeads(supplied by customer) are also included for rapid purification of nucleic acid products generated at two steps of the workflow. The library prep workflow could be used for purified DNA inputs from different sources including stool, soil, water, saliva, plant, urine, skin swab, vaginal swab, cheek swab, nasal/swab, plasma/serum, tongue swab, gum swab, and others.
The ITS1 Library Preparation Kit for Illumina has a streamlined procedure that reduces the handling time such that the library prep procedure can be completed in approximately 4 hours (see diagram below). Input DNA is first subjected to targeted PCR to amplify the ITS1 region of the fungal DNA.The post-PCR reaction is then cleaned up using AMPure XPbeads. Dual index primers are then added using a limited-cycle PCR. The indexed amplicons flanked by 5′ and 3′ barcoded adaptors are then cleaned using AMPure XPbeads. The libraries are then ready for quantification, pooling and sequencing.
Storage Conditions and Product Stability Norgen’s ITS1 Library Prep Kit for Illumina is shipped as one kit box (for the 24 prep kit) or two sub-component kits (for the 96 prep kit). All kits should be stored at -20°C upon arrival.
All kit components will remain stable for at least 1 year when stored at the specified storage conditions.