Attogene’s Cadmium Lateral Flow Kit can be used to detect Cadmium in the field.
Format: 10 test cassettes
Run Time: 15 Minutes
Cadmium contamination is a serious worldwide environmental problem. As it is difficult to detoxify by chemical or biological methods, gradual Cadmium accumulation in the nervous and cardiovascular systems of the human body can subsequently cause serious diseases. Long-term health consequences of drinking cadmium-contaminated food and water include numerous negative health effects. Attogene’s Cadmium Lateral Flow test gives results conforming of 5ppb or greater.
Other Products
Lateral Flow Development Starter Kit
Product Info
Document
Product Info
Twenty 4.5X60mm strips of each combination of nitrocellulose (4X), wicking material (2X), and sample pad (3X)
Blank lateral flow strips are the perfect companion during the development and feasibility testing of a lateral flow device. IN THE BEGINNING, the capture and test line reagents can be spotted onto the nitrocellulose portion of the blank strips at different concentrations, volumes and buffer conditions. This enables the user to determine the optimal conditions for subsequent spraying and enables the user to verify the test and controls will respond according to expectations before scaling up the process.
These blank strips are compatible with all of our colloidal gold products AND:
Lateral flow cassettes: C02022
Streptavidin CdSe/ZnS Quantum Dots For Lateral Flow: AU2043
Streptavidin Europium Chelate Microspheres For Lateral Flow: AU2050
Streptavidin Colloidal Gold For Lateral Flow: AU2017
Twenty 4.5X60mm strips of each combination of nitrocellulose (4X), wicking material (2X), and sample pad (3X)
A total of 480 strips are provided
100 cassettes
125mL of buffer
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
Acetic Acid
Assay Format:
Spectrophotometer, Microplate
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Decrease
Linear Range:
0.3 to 25 µg of acetic acid per assay
Limit of Detection:
0.254 mg/L
Reaction Time (min):
~ 4 min
Application examples:
Wine, beer, fruit and fruit juices, soft drinks, vinegar, vegetables, pickles, dairy products (e.g. cheese), meat, fish, bread, bakery products (and baking agents), ketchup, soy sauce, mayonnaise, dressings, paper (and cardboard), tea, pharmaceuticals (e.g. infusion solutions), feed and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Improved method
The Acetic Acid (Acetate Kinase Manual Format) test kit is suitable for the measurement and analysis of acetic acid in food and beverages.
This rapid and reliable manual acetic acid kit is simple to perform (only two absorbance readings required), and because a true end-point is measured, does not involve complicated calculations like other kits. This product is very stable both during storage and use (> 2 years), has extended linearity (compared to ACS based kits), contains PVP to prevent tannin inhibition, and is performed at a relatively low pH (7.4), thus minimising ester hydrolysis related interference. This method is suitable for the measurement of acetic acid/acetate in foods, beverages and other materials.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
View all of our acetic acid and other organic acid assay kits.
Document
The Acetic Acid (Acetate Kinase Manual Format) test kit is suitable for the measurement and analysis of acetic acid in food and beverages.
This rapid and reliable manual acetic acid kit is simple to perform (only two absorbance readings required), and because a true end-point is measured, does not involve complicated calculations like other kits. This product is very stable both during storage and use (> 2 years), has extended linearity (compared to ACS based kits), contains PVP to prevent tannin inhibition, and is performed at a relatively low pH (7.4), thus minimising ester hydrolysis related interference. This method is suitable for the measurement of acetic acid/acetate in foods, beverages and other materials.
500 Lateral Flow Cassettes (top and bottom)
Cassette Lettering: CT
Fits strips that are 86 mm x 6 mm
Perfect for development and product launch
Large quantities available