Campylobacter jejuni is a curved, rod-shaped and microaerophillic gram negative bacterium. It is one of the most common causal agents of gastroenteritis with diarrhea as the main symptom. While infection of C. jejuni is seldom life-threatening, it is considered one of the most common food-borne bacteria with over 2 million people infected per year in US alone. Infection of C. jejuni usually results from consumption of poorly prepared food including undercooked meat (particularly poultry), untreated water or raw unpasteurized milk. Traditional identification of C. jejuni involves culturing, however the microaerophilic characteristic of this bacterium make the enrichment process laborious and costly.
Storage Conditions and Product Stability All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival.
>The display can simultaneously display:all main parameters such as cold trap temperature,vacuum degree,sample temperature, and shelf temperature.
>Schematic diagram of equipment operating components,through graphic display to view the working status of each component of the equipment.
>Ithas the functions of cold trap precooling and vacuum pump preheating,and the time can be set by the userin the system. >Display whether the current running status is normal or not by numerical color.
o One-key operation,the operation is extremely simple,no special professional learning and training is required.
o Thermal electromagnetic over-current and short-circuit protection,making the equipment run more safely and stably.
o Active reminder of equipment maintenance time and vacuum pump replacement lubricating oil time.
o Ambient temperature monitoring,the device automatically reminds the alarm if the ambient temperature is too high.
o Optional eutectic point detection device and endpointjudgment detection system make freeze-drying more scientific.
Dryingchamber
· The separate drying chamber reduces the probability of damage caused byimproper handling of the drying chamber due to height and weight.The upper cover is anodized aluminum with anti-corrosion treatment.●Highly transparent plexiglass drying chamber,good light and heat radiation conduction.Reserve 6/12 external valve ports.· 316L stainless steel all black Teflon coating drying chamber,suitable for drying organic solvents and various corrosive samples,reserved for 6/12 external ports.· 316L stainless steel vertical multi-port multi-manifold external rack(The standard configuration is aplexiglass drying chamber,and one ofthe diying chambers can be optional)
Coldtrapandcondensingcoil
· The cold trap cavity and condensation coil are made of 316L stainless steel.Large opening and channel design,the gas can be quickly captured through the condensing coil.· The cavity and condensing coil are equipped with Teflon anti corrosion coating as standard,which can trap organic solvents and various corrosive solvents.· The condensing coil is placed in the cold trap to increase the condensate catchment area,which can effectively prevent external condensation.
Sampleshelves
· 316Lstainless steel stackable sample shelves,capable oflyophilizing machine solvents and various corrosive solvents.Each shelf can be placed and taken freely without manual work.The distance and height ofeach shelfcan be adjusted freely.-All black coating,good heat absorption performance.-Special hole for freeze-drying of centrifuge tubes,which is conducive to the drying of samples in centrifugetube containers.· All-aluminum Teflon surface anti-corrosion treatment electric heating shelf.
Refrigerationsystem
· Danffos compressorCopper plate heat exchanger,the largest area to increase heat dissipation· Unique refrigeration technology,the temperature of the cold trap can be lowered from ambient temperatureto below-80C°within 2 minutes.· Class A temperature sensor with high temperature accuracy and low error.· Multiple detection and alarm system,the refrigeration system pressure is too high or refrigeration failure cantimely alarm and take corresponding measures.
Techinical parameter
ItemNo
ST7003
ST7006
ST9006
Ice condenser capacity
3kg
6kg
6kg
Ice condenser temperature
-70℃
-70℃
-90℃
Cold trap volume
5L
10L
10L
Freeze dried chamber
Bell shape (standard configuration)/Multi manifold type/T-shaped frame type
Sample shelf
φ200mm.Single layer area 0.03m2 with 3-5 layers available
●260mm/485mm.Single layer area 0.055m²/0.185m².3-10 layers/optional ● Electric heating/manual capping/optiona
Vacuum pump
Extreme vacuum 5*10*mbar with a pumping capacity of 8m³/h optional pump of various types
Oil mist filte
Standard configuration
Vacuum pump connection pipe
Single forming stainless steel flexible pipe DN16 ISO-KF L-1.2m
Anti-corrosive treatment
Cold trap,condensing coil/all equipped with PTFE anti-corrosion treatment as standard. Freeze-drying organic solvents.
External valve
6pieces/optional
1-48 pieces/optional
Eutectic point detection system
Support/Optional
Data output analysis
Support/Optional
Powe
0.6kw
1.1kw
1.5kw
Size
420*545*455mm
510*570*500mm
Document
Freezer Dryer, 3kgs-6kgs water capturer Model: ST7003,ST7006,ST9006
Introducing the Fastin Assay Kit: Your Straightforward Solution for Elastin Quantification! Our user-friendly kit utilizes a dye-based method to measure elastin from in-vivo and in-vitro sources. It can be used to quantify various elastin forms, spanning from immature tropoelastin to mature, ‘insoluble’ elastin fibers.
Colorimetric Detection (513nm) (Endpoint)
Understanding Elastin: The Key to Tissue Flexibility
Tissues like lungs and arteries must maintain the ability to stretch and recoil repeatedly throughout an organism’s life. Elastin, a mature protein, is responsible for this elasticity and is usually present as insoluble fibers within the ECM. During development, these fibers are initially formed from a soluble precursor called tropoelastin.
What is the Fastin Assay?
The Biocolor Fastin assay is a user-friendly, dye-based means of quantifying elastins derived from both in-vivo and in-vitro sources. A variety of elastin forms can be assayed, from immature tropoelastin to mature ‘insoluble’ elastin fibres.
Further information on how the assay works can be found on the ‘Mode of Action‘ tab.
A list of suggested sample types can be found under the ‘Assay Specification‘ tab.
How does the Fastin assay detect Elastin?
The Fastin Dye Reagent contains an elastin-binding synthetic porphyrin, TPPS (5,10,15,20-tetraphenyl- 21H,23H-porphine). This affinity of TPPS for elastin was first observed when used as a ‘vital stain’ on live animals. Most tissues took up the dye initially but only elastin retained the TPPS molecules over time. [Winkelman, J. (1962), Cancer Res. 22, 589-596; Winkelman, J & Spicer, S. (1962), Stain Technol. 37, 303-305].
It has been proposed that the elastin binding of TPPS may be due to the retention of the acidic dye (which contains four charged sulfate groups) by the basic amino acid side chain residues of elastin.
How does the Fastin assay work?
Step 1. Incubation of samples containing soluble elastin with the Fastin Dye Reagent causes an elastin-dye complex to form. This insoluble complex then precipiates.
Step 2. Dye-labelled elastin is then isolated by centrifugation and the unbound dye removed. Elastin-bound dye is then eluted and measured spectrophotometrically.
Step 3. The elastin content of unknown samples can be calculated by comparison against a calibration curve prepared using a standard comprising water-soluble elastin (supplied with the kit).
Assay range
50 – 500µg/ml
Limit of Detection
50µg/ml
Detection Method
Colorimetric Detection (513nm) (Endpoint)
Measurements per kit
110 in total (allows a maximum of 48 samples to be run in duplicate alongside a standard curve).
Suitable Samples
In-vivo: tissues and fluids. Insoluble elastin will first require conversion to water soluble α-elastin using the oxalic acid reagents and extraction protocol supplied with the kit.
In-vitro: Elastin produced by cells during 2D/3D cell culture. NB elastin in conditioned cell media is typically below the detection limit of the kit.
Precautions
This kit is designed for research use only. Not for use in diagnostic procedures. Kit requires access to a centrifuge, heated water bath or block, as well as a spectrophotometer or colorimeter capable of absorbance detection at 513nm. Specific sample preparation protocols may require customer to provide further reagents, consult assay manual for further information.
Fastin elastin kit contents:
1. Dye Reagent (1x110ml)
2. α-elastin Reference Standard (1x5ml, 1.0 mg/ml soluble Bovine elastin)
6. 1.5ml micro-centrifuge tubes for dye-labelling reaction.
7. Assay kit manual
NB: Additional reagents may be required for sample preparation prior to assay. Consult manual or contact us for further details.
Document
Introducing the Fastin Assay Kit: Your Straightforward Solution for Elastin Quantification! Our user-friendly kit utilizes a dye-based method to measure elastin from in-vivo and in-vitro sources. It can be used to quantify various elastin forms, spanning from immature tropoelastin to mature, ‘insoluble’ elastin fibers. Colorimetric Detection (513nm) (Endpoint)