CDL7M touch screen with special programs for blood bag separation, can get good performance for platelet, red cell, all parts separation of blood. 6x2x1000ml bucket suitable for blood bag separation. Also with automatical lid lock open and close function, also wind shield can open along with door open. Model: CDL7M
Brand: Yingtai
Code: CDL7M blood bank centrifug
Detail
Features
1. Brushless frequency motor, in great torque, free maintenance, no power pollution, quick in speed up and down.
2. 7” LCD Touch screen display which indicates the program, rotor No, speed, time, RCF and temperature.
3. CFC-free refrigerant, pre-cooling function ,double cycle cooling, cold and hot alternating easily, free environment pollution and precise in temperature control.
4. Microprocessor control , 100 programs in store, 10 kinds of acceleration and deceleration for your choice.
5. Over speed and imbalance protection.
6. Speed, RCF, time, temperature can be edited during running.
7. High quality steel centrifuge body , stainless steel chamber, built-in stainless steel explosion-proof protect sleeve, 3 tiers protection, safe and reliable.
8. Automatic door open & close, as well as anti-pinch function (Optional).
CDL7M Technical Parameter:
Max. Speed
7000rpm
Max. RCF
11650×g
Max. Capacity
6×2400ml (12*500ml blood bag)
Time Range
1~99h59min59s
RPM/RCF Convert
Yes
Noise (dB)
≤ 65
Temperature
-20 ~ 40℃
Acc/Dec
10 Kinds
Speed Accuracy
±20r/min
Temperature Accuracy
±1℃
Voltage(V/Hz)
AC 220V/380V 50HZ/60HZ
Size (W x D x Hmm)
940×890×1000mm
Net Weight(Kg)
570KG
Certificates
CE,ISO & Calibration report are available
Special rotor for blood bag separation
Order No.
Rotor No.
Max Speed (rpm)
Max Volume(ml)
Max. RCF(×g)
05202
Swing Rotor
4000
6×2x1000ml
5210
Other Products
COVID-19 Real-Time PCR assay EUA (USA)
Product Info
Document
Product Info
This test has been authorized by FDA under an EUA for use by authorized laboratories.
The Primerdesign Ltd COVID-19 genesig® Real-Time PCR assay is a real-time RT-PCR assay intended for the qualitative detection of nucleic acid from SARS-CoV-2 in oropharyngeal swab specimens from patients suspected of COVID-19 by their healthcare provider. Testing is limited to laboratories certified under the Clinical Laboratory Improvement Amendments of 1988 (CLIA), 42 U.S.C. §263a, to perform high complexity tests.
FOR US ONLY Rapid detection and exclusive to the COVID-19 strain Does not detect other related coronavirus strains High priming efficiency Accurate controls to confirm extraction, and assay validity Lyophilised components for ambient shipping Highly specific detection profile This test has been authorized by FDA under an EUA for use by authorized laboratories.
Suitable for self-collection of saliva samples supervised by a trained individual in the collection procedure by watching the training video and reading over the collection instructions.
Norgen’s Saliva RNA Collection and Preservation Devices Dx are designed for 1) safe and non-invasive supervised self-collection of saliva specimens and 2) preservation of RNA in saliva specimens at ambient temperature. Each of the 50 Saliva RNA Collection and Preservation Devices Dx consists of 3 components: (1) Saliva Collection Funnel and Collection Tube, (2) Collection Tube Cap, and (3) Norgen’s Saliva RNA Preservative contained within a sealed squeezable ampoule. Saliva collection is performed through supervised self-collection. Saliva samples are collected by spitting inside the Collection Funnel which has been assembled with the Collection Tube. After collecting the required volume of saliva the Collection Funnel is removed and the contents of the Preservative Ampoule are then added and mixed with the collected saliva. The Saliva Collection Tube is subsequently sent to the laboratory for RNA isolation and analysis. RNA can be isolated from the preserved saliva samples using Norgen’s Saliva/Swab RNA Purification Kits Dx (Cat# Dx69100, Dx69300). Each of Norgen’s Collection Tubes is labeled with a unique serial number that can be used for secure and anonymous tracking of the sample. The saliva RNA in preserved samples is stable for up to 2 months at room temperature. This kit is ideal for collecting and preserving RNA samples for in vitro diagnostic use for medical purposes. This kit can be used to collect and preserve viral RNA, including SARs-CoV-2 RNA for detection of COVID-19.
Norgen’s Saliva RNA Collection and Preservation Devices Dx do not provide a diagnostic result. It is the sole responsibility of the user to use and validate these devices in conjunction with a downstream in vitro diagnostic assay.
Saliva RNA Preservative
Norgen’s Saliva RNA Preservative is an aqueous storage buffer designed for rapid cellular lysis and subsequent preservation of RNA from fresh saliva specimens. The buffer eliminates the need to immediately process or freeze samples and allows the samples to be shipped to centralized testing facilities at ambient temperature. The components of the buffer allow samples to be stored for up to 2 months at room temperature. The Saliva RNA Preservative also inactivates all bacteria, yeast and viruses present in the saliva sample.
Nucleic Acid Isolation from Preservative
Saliva RNA can be isolated from the preserved saliva samples using Norgen’s Saliva/Swab RNA Purification Kits Dx (Cat# Dx69100, Dx69300). To minimize irregularities in diagnostic results, suitable controls for downstream applications should be used.
The Collection Device should be kept tightly sealed and stored at room temperature for up to 2 years without any reduction in kit performance (The collection due date is written on the device label).
Once collected, saliva RNA is stable for up to 2 months when kept tightly sealed and stored at room temperature.
The Collection Tube, the Collection Funnel and the Device Container of each individual Saliva RNA Collection and Preservation Device are recyclable.
Kit Components
Cat. RU53800 (50 Devices)
Individual Saliva RNA Collection and Preservation Devices
50
Donor Procedure Flowchart
1
Product Insert
1
Individual Saliva RNA Collection and Preservation Device Dx Contents