Cell Culture Plate provide excellent smoothness and uniformity based on accurate molding technology. By such property, clear view can be available when examine with a microscope.
Specifications: 6wells
12wells, 24wells., 48wells, 96wells
Detail
Cell Culture Plate 6 Wells
Cell Culture Plate provide excellent smoothness and uniformity based on accurate molding technology. By such property, clear view can be available when examine with a microscope.
Specifications: 6wells
12wells, 24wells., 48wells, 96wells
PRODUCT FEATURES
The product is made of medical grade USP CLASS VI polymer polystyrene
The product is made under a 100,00- class dust-free manufacturing site
Two kinds of product line up are providing.
For adherent cell culture: Initial adherence and proliferative property of cells via hydrophilic surface treatment.
For suspension cell culture: The surface is resistant to cell adherence, which minimizes damage or loss of cell.
Listeria monocytogenes have emerged as significant foodborne pathogens that pose a serious public health problem. As the causative agent of Listeriosis, L. monocytogenes has the highest rate of fatality rate among all foodborne pathogens. L. monocytogenes is a facultatively intracellular, Gram-positive bacterium that could survive high and low temperatures, low pH. It is a rare causative agent of mastitis in cow. However, due to its ability to resist various food processing technologies as well as to grow at low temperature, L. monocytogenes is know to be associated with both raw and pasteurized milk, as well as dairy products such as cheese. As little as 1000 organisms may cause the disease with pregnant, new-born, and immunocompromised individuals the most susceptible.
The Listeria monocytogenes TaqMan PCR Kit Dx is shipped on dry ice. The components of the kit should be frozen upon arrival. If one or more of the components is not frozen when the kit is received, or if any of the components have been compromised during shipment, please contact Norgen Biotek for assistance. All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 3 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component
Cat. DxTM30400 (24 rxns)
MDx TaqMan 2X PCR Master Mix Dx
550 µL
L. monocytogenes Primer Mix Dx
2 x 70 µL
L. monocytogenes Positive Control Dx – 200,000 copies/μL
The Opentrons Flex 96-Channel pipette enables accurate high throughput pipetting, optimized for working in 96-well plates. Flex Pipettes use air displacement technology to offer highly accurate pipetting with pipette volume ranges from 5 – 1000 μL.
Smart sensors support automatic calibration, real-time positioning, and error detection. The 96-channel pipette occupies both pipette mounts and can easily be removed and swapped to an alternate pipette configurations to adapt your workflow needs.
Four 96-Channel Tip Rack Adapters are included with the purchase of one Flex 96-Channel Pipette.
Document
The Opentrons Flex 96-Channel pipette enables accurate high throughput pipetting, optimized for working in 96-well plates. Flex Pipettes use air displacement technology to offer highly accurate pipetting with pipette volume ranges from 5 – 1000 μL.
Smart sensors support automatic calibration, real-time positioning, and error detection. The 96-channel pipette occupies both pipette mounts and can easily be removed and swapped to an alternate pipette configurations to adapt your workflow needs.
Four 96-Channel Tip Rack Adapters are included with the purchase of one Flex 96-Channel Pipette.
Produced by reverse osmosis, ion-exchange, electro-deionization, ultrafiltration, UV treatment (UVC & 185 nm), 0.1 μm membrane filtration
Nuclease-free, protease-free, endotoxin-free
Suitable for molecular biology applications (qPCR, NGS etc.)
Suitable for cell culture applications
Produced in an ISO certified GMP laboratory
Water system is routinely monitored for compliance with QC standards
The Norgen water purification system has been designed in conjunction with experts from Millipore Sigma. The Ultrapure NFW is purified in a two-stage process. The first stage, to produce type II water, includes pre-treatment with activated charcoal and polyphosphate, this water then undergoes reverse osmosis, electro-deionization and ion exchange to remove contaminants as well as UV treatment for disinfection. The Pure water then flows to a second system in a clean room with an additional 4 layers of purification. After passing through an additional ion exchange column, the water is then subjected to Ultrafiltration to remove particulates, bacteria, & ionic contaminants down to trace level, the water is then treated with UV light (182 nm wavelength) to break down organic matter. Lastly a second Ultrafilter for the production of pyrogen-, nuclease- and bacteria-free water at 18.2 MΩ. This water is of utmost purity and suitable for direct use in molecular biology applications such as qPCR and NGS, as well as cell culture and other applications.
Product Specifications
pH
n/a (highly pure water does not contain enough ions for an exact pH determination.)
Recommended Storage
Room Temperature
Grade
Ultrapure (ASTM Type I)
Biological Activity
DNase-, RNase-, Protease-, Endotoxin- Free
TOCs
< 50 ppb
Resistivity
> 18 MΩ-cm
Treatment
Not DEPC-Treated
Quantity
100 mL, 500 mL, 1000 mL
Purification Methods
Activated charcoal, polyphosphate, reverse osmosis, electro-deionization, ion exchange, UV, ultrafiltration
Shipping Conditions
Room Temperature
Details
Applications For use in any molecular biology application
Storage Conditions Norgen’s Nuclease-Free Water should be stored at room temperature. Storage at +4°C or -20°C is optional.
Precautions and Disclaimers This product is designed for research purposes only. It is not intended for human or diagnostic use.