CP0203J Triple Wrapped Irradiated Plate-Tryptic Soy Agar with Lecithin Tween 80
Facebook
X
Pinterest
Email
55mm*10 plates / bag
Detail
Introduction
Usages:
For monitoring and detection of surface of equipment and personnel hygiene which have disinfectant or antibiotics.
Advantage: 1.This series of products was filling at A level of environment, and final sterilization by Gamma ray irradiation, triple packaging insure sterility and long shelf life. 2.Each dish was marking label product name, batch number, expiration date .Information is available of traceability. 3.Inner additional desiccant, reducing formation of condensation water, while inner additional sterile paper and plastic bags for easier transfer and cultivation. 4.Triple packing dense bags to avoid the penetration of hydrogen peroxide; clean gas was filled as a buffer to reduce broken bags and dish in transit.. 5.This series of products is available to store at (2-25 ℃), shelf life of up to 6 months.
Storage: Store in a cool (2-25 ℃), dry place, away from bright light. Storage period of 6 months.
Specifications: 55mm*10 plates / bag
Other Products
Plasma/Serum Exosome and Free-Circulating RNA Isolation Kits
Product Info
Document
Product Info
Overview
Isolate all sizes of RNA, including microRNA, irrespective of size or GC content, without bias.
Versatile sample input ranges
Isolate all sizes of free-circulating RNA, including microRNA
The purified exosomal RNA is free from any circulating RNA-binding proteins
No phenol extractions, Proteinase K treatment, nor carrier RNA
No time-consuming ultracentrifugation, filtration nor special syringes are required
No precipitation reagents, nor overnight incubation required
Concentrate isolated exosomal RNA and are free-circulating RNA into a flexible elution volume ranging from 50 µL to 100 µL
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
These kits provide a fast, reliable and convenient method to sequentially isolate and concentrate exosomal RNA as well as Free-Circulating RNA from different plasma/serum sample volumes. The purification is based on spin column chromatography that employs Norgen’s proprietary resin. These kits are designed to isolate all sizes of RNA, including microRNA as well as all sizes of the free-circulating protein-bound RNA, including microRNA. These kits provide a clear advantage over other available kits in that they do not require any special instrumentation, protein precipitation reagents, extension tubes, phenol/chloroform or protease treatments. Moreover, these kits allow the user to elute into a flexible elution volume ranging from 50 µL to 100 µL. The RNA isolated from the purified exosomes is free from any protein-bound circulating RNA and is of the highest integrity. Moreover, the free-circulating, protein-bound, RNA is free from any exosomal RNA. The purified RNA can be used in a number of downstream applications including real time PCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, and expression array assays.
Plasma/Serum Exosome and Free-Circulating RNA Isolation Mini Kit
For sample volumes ranging from 50 µL to 1 mL.
Plasma/Serum Exosome and Free-Circulating RNA Isolation Midi Kit
For sample volumes ranging from 1 mL to 4 mL.
Plasma/Serum Exosome and Free-Circulating RNA Isolation Maxi Kit
All sizes, including miRNA and small RNA (< 200 nt)
Elution Volume
50 – 100 µL
Time to Complete 10 Purifications
40 – 45 minutes
Average Yields*
Variable depending on specimen
*Please check page 5 of the product insert for the average yields and the common RNA quantification methods
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.
Important Note This kit is suitable for the purification of exosomes from fresh or frozen serum or plasma prepared from blood collected on either EDTA or Citrate. Plasma samples prepared from blood collected on heparin should not be used as heparin can significantly interfere with many downstream applications such as RT-PCR.
Exosomal RNA Isolation Kit (for the extraction of RNA from EVs that have been isolated using IZON’s qEV columns)
Product Info
Document
Product Info
Overview
Extract high quality & quantity total RNA including miRNA
No phenol step required; isolate all RNA in one fraction
Bind & elute all RNA irrespective of size or GC content, without bias
Very sensitive & linear down to a few cells without the need for carrier RNA
Isolate from a wide variety of specimens
Purified RNA is suitable for a variety of downstream applications, including Small RNA Sequencing. Find out more information on Norgen’s NGS services
Available in a variety of formats to suit your needs
Purification is based on spin column chromatography that uses Norgen’s resin separation matrix
Norgen’s Exosomal RNA Isolation Kit (for the extraction of RNA from EV’s that have been isolated using IZON’s qEV columns) constitutes an all-in-one system for the isolation of exosomal RNA from exosomes previously isolated using IZON’s qEV columns or concentrated using IZON’s EV Concentration kit. This kit allows for the isolation of RNA from intact extracellular vesicles (EVs) where the purification is based on spin column chromatography that employs Norgen’s proprietary resin.
The kit is designed to isolate all sizes of extracellular vesicle RNA, including microRNA. The kit provides a clear advantage over other available kits in that it does not require any special instrumentation, protein precipitation reagents, extension tubes, phenol/chloroform or protease treatments. Moreover, the kit allows the user to elute into a flexible elution volume ranging from 50 μL to 100 μL. The purified RNA is of the highest integrity, and can be used in a number of downstream applications including real time PR, reverse transcription PCR, Nothern blotting, RNase protection and primer extension, and expression array assays.
Details
Storage Conditions and Product Stability All buffers should be kept tightly sealed and stored at room temperature (15–25°C). This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.
CE-IVD marked version available for in vitro diagnostic use
Available in TaqMan format for analysis
The Zika Virus (ZIKV) is an emerging mosquito-borne virus that was first identified in Uganda in 1947 in Rhesus monkeys through monitoring of sylvatic yellow fever. During large outbreaks in French Polynesia and Brazil, national health authorities reported potential neurological and auto-immune complications of ZIKV disease. Agencies investigating the Zika outbreaks are finding an increasing body of evidence about the link between ZIKV and microcephaly. Infection with ZIKV may be suspected based on symptoms and recent history (e.g. residence or travel to an area where ZIKV is known to be present). Zika virus diagnosis can only be confirmed by laboratory testing for the presence of ZIKV RNA in the blood or other body fluids, such as urine or saliva.
ZIKV TaqMan RT-PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
ZIKV TaqMan RT-PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s RT-PCR Master Mix (#28113) or customer supplied master mix
All kit components can be stored for 1 year after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.