CP0203J Triple Wrapped Irradiated Plate-Tryptic Soy Agar with Lecithin Tween 80
Facebook
X
Pinterest
Email
55mm*10 plates / bag
Detail
Introduction
Usages:
For monitoring and detection of surface of equipment and personnel hygiene which have disinfectant or antibiotics.
Advantage: 1.This series of products was filling at A level of environment, and final sterilization by Gamma ray irradiation, triple packaging insure sterility and long shelf life. 2.Each dish was marking label product name, batch number, expiration date .Information is available of traceability. 3.Inner additional desiccant, reducing formation of condensation water, while inner additional sterile paper and plastic bags for easier transfer and cultivation. 4.Triple packing dense bags to avoid the penetration of hydrogen peroxide; clean gas was filled as a buffer to reduce broken bags and dish in transit.. 5.This series of products is available to store at (2-25 ℃), shelf life of up to 6 months.
Storage: Store in a cool (2-25 ℃), dry place, away from bright light. Storage period of 6 months.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected*. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings
Mycoplasma is the smallest and simplest prokaryotic organism. There is a risk of mycoplasma contamination during cell culture, and mycoplasma contamination of cells has become a common problem worldwide. Mycoplasma contamination may seriously affect the state of cells, change the gene expression and metabolic characteristics of cells, lead to slow cell growth, abnormal differentiation and death, and seriously affect cell function. Bacteria, yeast or mold contamination in cell culture can be seen under an optical microscope, but mycoplasma contamination is usually not visible under an optical microscope and must be detected by specific detection methods. Common methods for detecting mycoplasma contamination include mycoplasma isolation and culture, special biochemical tests such as ELISA and luminescence, and DNA fluorescent staining detection. Among the above detection methods, most of the operation steps are relatively cumbersome, the sensitivity is not high, the mycoplasma types cannot be distinguished, special instruments are required, or the time required is long. The qPCR method is relatively simple and convenient to operate, and the results can be obtained in 2 hours.
Features of MycoSEQ Mycoplasma Detection Kit
• Provide results in less than 2 hours. Good negative and positive controls. • No live mycoplasma required: The MycoSEQ Mycoplasma Detection Kit does not contain any live mycoplasma and does not require the use of live mycoplasma for validation • Can be used with gDNA, inactivated mycoplasma, or live mycoplasma • Can be used as an alternative to the standard 28-day culture test • Can be used in conjunction with culture-based methods to provide preliminary results while awaiting the 28-day test results
The MycoSEQ Plus Mycoplasma Detection Kit is part of an integrated workflow for adventitious drug, impurity, and contaminant detection during biopharmaceutical manufacturing. The entire workflow includes the sample preparation kit, which provides a manual sample preparation method, which together with the qPCR analysis can provide results in 2 hours. (Please note that complex matrices may require additional upfront processing steps as described in the various available protocols.)
Contents and Storage
• Mycoplasma qPCR MIX, store at -15°C to -25°C, store at 2°C to 8°C after first use, protected from light. • Mycoplasma Positive Control, -15°C to -25°C. • Mycoplasma Negative Control, store at -15°C to -25°C, store at 2°C to 8°C after first use.
Document
Note: Price not include shipment & duty, contact us to get full quote.
DuckyBio’s Mycoplasma PCR Detection Kit is a TaqMan™-based quantitative PCR (qPCR) kit for detecting mycoplasma contamination in biological materials such as cultured cells. Designed and tested using criteria often applied toward rapid mycoplasma detection in biotherapeutic manufacturing cell culture lot release, the MycoSEQ Plus kit enables results that meet or exceed guidance on sensitivity and specificity expectations as described in European Pharmacopoeia (E.P. 2.6.7, 2007), US Pharmacopoeia (US63) and Japanese Pharmacopoeia. When used with a suitable sample preparation method, the MycoSEQ Plus kit can detect less than 5 CFU/mL.