
Introduction
Place of Origin: Guangdong, China
Warranty: 2 years
Customized support: OEM
Brand Name: HKM
Model Number: CRM010
Reagent grade: Biochemical Reagent
Form: Powder
Color: Light yellow
Type: Candida Agar
1000mL

Place of Origin: Guangdong, China
Warranty: 2 years
Customized support: OEM
Brand Name: HKM
Model Number: CRM010
Reagent grade: Biochemical Reagent
Form: Powder
Color: Light yellow
Type: Candida Agar
Opentrons Tough 0.2 mL 96-Well PCR Plate, Full Skirt, RNase/DNase-free. Strong polycarbonate frame with thin-walled polypropylene wells for high-performance thermal cycling without warping. Ideal for use within automated liquid handlers with or without a gripper. 0.2 mL total well volume, 0.1 mL working volume. 25 count. Not for therapeutic use SP-2396.
Opentrons Tough 0.2 mL 96-Well PCR Plate, Full Skirt, RNase/DNase-free. Strong polycarbonate frame with thin-walled polypropylene wells for high-performance thermal cycling without warping. Ideal for use within automated liquid handlers with or without a gripper. 0.2 mL total well volume, 0.1 mL working volume. 25 count. Not for therapeutic use SP-2396.
Compact and stylish designed, the BioShake iQ high-end thermoshaker lets you perform all your standard mixing runs with a minimum of adjustments.
The BioShake iQ offers outstanding performance to handle a wide range of applications across biotechnology, pharmaceutical and academic research.
By combining the mixing operation with the incubation phase, reaction process times and operator workload are reduced and efficiency of many procedures is increased, resulting in a higher throughput.
The first-class finished aluminium housing gives the BioShake iQ its essential functionality. It provides a high amount of security, device stability and ensures a long service life.
German designed and manufactured, BioShake iQ thermoshaker offer an ultra-efficient, 2-dimensional shaking axis so that samples mix completely in a fraction of the time of competing systems.
The mixing orbit of 2.0 mm is always constant. The orbital shaking is precisely controlled, in fact, that you need never spin down your plates after mixing. Even tubes, vials, high density plates, or low sample volumes, offer no obstacle for these precision tools.
Fully adjustable between 200 rpm and 3,000 rpm, well beyond the speeds of most other brands, guarantees fast, splatter-free, mixing for tubes, glass vials or across an entire 384-well microplate.
The BioShake iQ heats from ambient to 99°C in a short time, provides ease of use features, amazing comfort and maximum safety.
Within the BioShake iQ thinnest large-area heating elements and sensors are integrated. During the heat up time the special electronic control system guarantees the same temperature for all vessels with minimal deviations.
Temperatures are selectable from ambient temperature to 99°C in steps of 1.0°C. The nominal regulation accuracy is better than ±0.1°C with a uniformity of temperature distribution better than ±0.5°C at 45°C across the heating surface.
Exchangeable thermo adapter plates and thermal blocks enable a perfect adaptation to microplates, tubes or glass vials.
In the corners eight spring clamps are inserted for easy fixation of skirted microplates and deep well plates in SBS format 127.7 x 85.5 mm without an attached adapter. These spring clamps lock the microplate quickly and safely, even at the highest mixing frequencies.
For flexible and deformable PCR plates we recommend using of the related PCR adapter.
Fast mixing processes with frequent plate changes can be performed in the routine as easy and safe.
The BioShake iQ is operated from the front face of the enclosure which includes touch buttons and a display.
Special buttons for start, stop and storage of time and mixing modes enable the instrument to run complex applications. This opens new points of view on the daily laboratory work and optimizes routine application enormously.
The short mix button allows short and fast mixing in between.
The two line LCD display guarantees simultaneous and safe reading of all programmed and measured parameters as time, mixing frequency and temperature.
The BioShake iQ comes with a variety of standardized and specific adapter plates. The replacement of the adapters are very simple.
Perfect shaped adapters allow an optimal fit for standard tubes, lysis tubes, microplates, glass vials and other sample vessels. An excellent temperature uniformity and homogeneity is guaranteed for all samples.
Unique and efficient design combined with the most compact housing result in beautiful and well-defined laboratory equipment. Therefore, the first-class finished aluminium housing gives the BioShake iQ its essential functionality. It provides a high amount of security, device stability and ensures a long service life.
Safety of the user and ease of use are clearly a priority.
A perfectly harmonious blend of high-tech and handmade. “Made in Germany” has always been a recipe for success for QInstruments. 100% of QInstruments production takes place in Germany.
The focus is on human diligence and on being environmentally friendly. The company upholds its quality guarantee by means of consistent quality management. For more than 15 years these lab automation professionals from Jena have used only high-quality materials to ensure sustainable production, applied innovative thinking and undertaken research in a future-oriented way – all as a matter of course.
For microplates, tubes and glass vials
Fast & high-precision heating
Temperature range: ambient to 99°C
Precise mixing from 200 – 3,000 rpm
Wide range of thermo adapters
Stylish aluminium housing
Hipure Stool RNA Kit is specially designed for stool RNA extraction. This kit is suitable for extracting high-purity microbial or host cell RNA from ≤0.1g stool samples. The kit adopts silica gel column purification technology and original solution system, which can effectively remove humic acid and other inhibitory factors in stool samples. The purified RNA can be directly used in RT-PCR, Northern hybridization and other experiments.
Specifications
| Features | Specifications |
| Main Functions | Isolation total RNA from 100-150mg stool sample |
| Applications | RT-PCR, Northern hybridization and other experiments |
| Purification method | Mini spin column |
| Purification technology | Silica technology |
| Process method | Manual (centrifugation or vacuum) |
| Sample type | Stool |
| Sample amount | 100-150 mg |
| Elution volume | ≥30μl |
| Time per run | ≤50 minutes |
| Liquid carrying volume per column | 100µg |
| Binding yield of column | 800µl |
The HiPure silica gel column uses a high binding ability glass fiber filter membrane as the substrate. Under the condition of high concentration of ionizing agent (such as Guanidinium chloride or guanidine isothiocyanate), the filter membrane can adsorb nucleic acid through hydrogen bonding and electrostatic and other physical factors, while protein or other impurities are not adsorbed and removed. The filter membrane that has adsorbed nucleic acids is washed to remove proteins and salts. Finally, low salt buffer solution (such as Buffer TE) or water can be used to wash out the nucleic acids adsorbed on the filter membrane. The obtained nucleic acid has high purity and can be directly used in various downstream experiments.
The stool samples are homogenized in the lysis solution, further lysed in a high-temperature water bath, and RNA is released into the lysis solution. Chloroform extraction removes genomic DNA and impurities, transfer the supernatant to an alcohol free binding solution, purify RNA through a column, and finally elute RNA with RNase Free Water. The purified RNA can be directly used for experiments such as PCR, Southern hybridization, and enzyme digestion.
Advantages
Kit Contents
| Contents | R418502 | R418503 |
| Purification Times | 50 Preps | 250 Preps |
| HiPure RNA Mini Columns | 50 | 250 |
| 2ml Collection Tubes | 50 | 250 |
| Glass Beads (0.1~0.6mm) | 30 g | 150 g |
| Buffer SPL | 30 ml | 140 ml |
| Buffer PHC | 30 ml | 140 ml |
| Buffer GRP | 60 ml | 250 ml |
| Buffer RW1 | 50 ml | 250 ml |
| Buffer RW2 * | 20 ml | 2 x 50 ml |
| RNase Free Water | 15 ml | 30 ml |
Storage and Stability
The kit components can be stored at room temperature (15–25°C) and are stable for 18 months under these conditions. At low temperatures, Buffer SPL may form precipitates, dissolve it by 55°C water bath. After receiving the product, Buffer PHC should be stored at 2-8°C.
Hipure Stool RNA Kit is specially designed for stool RNA extraction. This kit is suitable for extracting high-purity microbial or host cell RNA from ≤0.1g stool samples. The kit adopts silica gel column purification technology and original solution system, which can effectively remove humic acid and other inhibitory factors in stool samples. The purified RNA can be directly used in RT-PCR, Northern hybridization and other experiments.