CE-IVD marked version available for in vitro diagnostic use
Available in TaqMan format for analysis
Cryptosporidium is a parasite found in water that causes an infection in mammals termed cryptosporidiosis. It is one of the most common water-borne diseases and is found world-wide. It affects the intestines of mammals and typically causes an acute short-term infection. The most common symptom is self-limiting diarrhea in healthy individuals, however in immunocompromised individuals the symptoms are particularly severe and often fatal. There is no specific treatment for cryptosporidiosis other than fluid rehydration and management of any pain. Therefore early detection of Cryptosporidium in water is the foremost action to prevent the infection.
Cryptosporidium TaqMan RT-PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
Cryptosporidium TaqMan RT-PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s RT-PCR Master Mix (#28113) or customer supplied master mix
Storage Conditions and Product Stability All kit components can be stored for 1 year after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival.
Component
Cat. TM39150 (100 preps)
Cat. TM39110 (100 preps)
MDx TaqMan 2X PCR Master Mix
2 x 700 μL
–
Cryptosporidium Primer & Probe Mix
280 μL
280 μL
Cryptosporidium Positive Control
150 μL
150 μL
Nuclease-Free Water (Negative Control)
1.25 mL
1.25 mL
Product Insert
1
1
Other Products
N-(Amino-PEG4)-N-bis(PEG4-propargyl) HCl salt
Product Info
Document
Product Info
N-(Amino-PEG4)-N-bis(PEG4-propargyl) HCl salt is a trifunctional linker with two terminal alkynes and a primary amine. The terminal alkynes can be linked to azides using copper click chemistry while the primary amine is reactive towards carboxylic acids, NHS esters, ketones and aldehydes to form a variety of stable bonds.
Document
N-(Amino-PEG4)-N-bis(PEG4-propargyl) HCl salt is a trifunctional linker with two terminal alkynes and a primary amine. The terminal alkynes can be linked to azides using copper click chemistry while the primary amine is reactive towards carboxylic acids, NHS esters, ketones and aldehydes to form a variety of stable bonds.
Livestock Disease Kit with African swine fever virus Test Kit for Nucleic Acid Detection
Product parameters:
Kit composition(WLRE8208KIT 48T/Pack)
Composition
Content
E buffer
1 mL×2 Tubes
B buffer
150 μL×1Tube
Positive control template
100 μL×1Tube
Reagents
48T
Product features and advantages:
Product features and advantages
Features
Advantages
High sensitivity
1 copies/ml
Strong specificity
Specificity is superior to PCR
Short reaction time
20min
Polymorphic reagent
Liquid, freeze-dried powder, freeze-dried ball
Easy to operate
Few steps of liquid dispensing; It is even possible to add only samples and amplify to get the resultsDesign of primers and probe is simple
Easy to store and transport
It is best preserved at -20℃, and can be stored at room temperature for up to 30 days in a cool place away from light.The freeze-dried form has a long storage time and is convenient for transportation
Low requirements on equipment
Applicable to Applied Biosystems 7500, QuantStudio 3/5, QuantStudio 6/7 Flex fluorescence quantitative PCR instrument;Applicable to our WL-16-III and other isothermal fluorescence detector
Product application:
Application
Ultra-clean laboratory
African Swine Fever Virus Isothermal Detection
Indoor
Operation procedure and process:
Operation procedure and process:
Take out the liquid components of the kit in advance, thaw at room temperature, and shake to mix.
Prepare freeze-dried reagents according to the number of samples to be tested, negative and positive controls, and add 37.5 μL E buffer to each freeze-dried reagent.
Select the appropriate nucleic acid extraction method and reagent to extract the sample nucleic acid
Add 10 μL nucleic acid template to the reaction tube (the amount of template can be adjusted to be filled with sterile water; That is, 10 μL nucleic acid template plus sterile water), 10 μL positive control template was added to positive control, and 10 μL sterile water was added to negative control
Add 2.5μL B buffer to each reaction tube and close the tube cap (for multiple reactions, it is recommended to add B buffer to the inside of the tube cap)
Thoroughly mix the reaction tube upside and down for 8-10 times. After mixing, shake (or rapidly centrifuge) the reaction liquid to the bottom of the tube and transfer it to the amplification zone.
Performence Comparison Data:
No.
TT value
Template concentration
Result determination
1
4.2
10-1
Positive
2
5.5
10-2
Positive
3
10.2
10-3
Positive
4
17.0
10-4
Positive
5
12.0
10-5
Positive
6
–
10-6
Negative
7
–
10-7
Negative
8
Negative control
Negative
Support and Services:
Livestock Disease Kit Technical Support and Services
We provide technical support and services for our Livestock Disease Kit. We are committed to helping you get the most out of your product and ensuring your satisfaction with our products and services.
Our technical support staff is available to answer any questions you may have about the product.
We offer online tutorials and user guides to help you understand the product better.
We provide technical assistance to help troubleshoot any issues you may be having with the product.
We offer a warranty on our products.
If you have any questions or need technical support, please do not hesitate to contact us. We are here to help you make the most of your Livestock Disease Kit.
FAQ:
Q: What diseases can Livestock Disease Kit detect? A: Livestock Disease Kit can detect different infectious diseases, such as Foot and Mouth Disease, Bluetongue Disease, Bovine Viral Diarrhea.
Q: How does Livestock Disease Kit work? A: Livestock Disease Kit uses advanced MIRA technology to amplify the target DNA/RNA targent sequences , and detect the disease by analyzing the amplified sequences.
Q: How long does it take to get results from Livestock Disease Kit? A: Livestock Disease Kit can give a result within 5-20 mins.
Q: What type of sample is suitable for Livestock Disease Kit? A: Livestock Disease Kit is suitable for blood, serum, and tissue samples.
Q: Does Livestock Disease Kit require professional equipment? A: No, Livestock Disease Kit does not require any professional equipment,can use with our isothermal equipment or pcr machine
Document
Livestock Disease Kit with African swine fever virus Test Kit for Nucleic Acid Detection
Norgen’s Saliva RNA Collection and Preservation Devices are designed for simple and non-invasive saliva collection and preservation of RNA in saliva samples at ambient temperature. Each of the 50 Saliva RNA Collection and Preservation Devices consists of 3 components:
Saliva Collection Funnel and Collection Tube
Collection Tube Cap
Norgen’s Saliva RNA Preservative contained within a sealed squeezable ampoule
Saliva samples are collected by spitting inside the Collection Funnel which has been assembled with the Collection Tube. After collecting the required volume of saliva the Collection Funnel is removed and the contents of the Preservative Ampoule are then added and mixed with the collected saliva. The Saliva Collection Tube is subsequently sent to the laboratory for RNA isolation and analysis. RNA can be isolated from the preserved saliva samples using Norgen’s Saliva/Swab RNA Purification Kits (Cat# 69100, 69300). Each of Norgen’s Collection Tubes is labeled with a unique serial number that can be used for secure and anonymous tracking of the sample. The Saliva RNA in preserved samples is stable for up to 2 months at room temperature. This kit is ideal for collecting and preserving RNA samples for epidemiological and population studies.
Saliva RNA Preservative
Norgen’s Saliva RNA Preservative is an aqueous storage buffer designed for rapid cellular lysis and subsequent preservation of RNA from fresh specimens. The buffer eliminates the need to immediately process or freeze samples and allows the samples to be shipped to centralized testing facilities at ambient temperature. The components of the buffer allow samples to be stored for up to 2 months at room temperature.
When stored at room temperature, unused Norgen Saliva Preservative Tubes are stable through to the collect-before date without any reduction in performance. Please see the device insert or tube label for collect-before date.
Once collected, saliva RNA is stable for up to 2 months when kept tightly sealed and stored at room temperature.
The Collection Tube, the Collection Funnel and the Device Container of each individual Saliva RNA Collection and Preservation Device are recyclable.
Kit Components
Cat. RU53800 (50 Devices)
Individual Saliva RNA Collection and Preservation Devices
50
Donor Procedure Flowchart
1
Product Insert
1