Attogene’ s Cylindrospermopsin Lateral Flow Kit can be used to detect Cylindrospermopsin in source water samples.
Format: Rapid-Water – Run Time: 30 Minutes, enough to run two samples (undiluted and a 10 fold dilution) and negative control.
Cylindrospermopsin (CYN) is a potent cyanotoxin synthesized by select species of cyanobacteria, prominently including Cylindrospermopsin raciborskii. It belongs to the tricyclic alkaloid class, exhibiting a molecular weight of approximately 415 Da. Structurally, cylindrospermopsin features an uracil ring fused with a hydantoin moiety, alongside a guanidino group, attributes that render it highly soluble and polar in aqueous environments.
Cylindrospermopsin is notorious for its profound toxicity towards aquatic organisms and its potential threat to human health through exposure via contaminated water and food sources. Consequently, rigorous monitoring protocols are essential in regions prone to cyanobacterial blooms, where cylindrospermopsin can accumulate in freshwater reservoirs and other aquatic habitats. In recognition of these risks, regulatory bodies such as the United States Environmental Protection Agency (EPA) have implemented an action level guideline. As of 2019, EPA 10-day drinking water health advisory for cylindrospermopsin recommended a threshold of 0.7 parts per billion (ppb), or 700 parts per trillion (ppt) for children under the age of six, and 3 parts per billion, 3000 parts per trillion for anyone older, to effectively manage cylindrospermopsin levels. This precautionary measure aims to uphold both environmental sustainability and public health integrity by minimizing exposure risks. The EPA has also drafted a human health recreational water quality criterion to protect human health at 8,000ppt.
Do not Drink – 0.7 μg/L for bottle fed infants and preschool children, pregnant and nursing woman, elderly immunocompromised and liver conditions
Do not Drink – 3.0 μg/L for school age children to adults
Do Not Use – 20 μg/L
EPA Draft Human Health Recreational Ambient Water Quality Criteria to protect human health: 8 μg/L
Other Products
Acetic Acid Assay Kit (ACS Analyser Format)
Product Info
Document
Product Info
K-ACETAF
SKU: 700004255
141.6 mL of prepared reagent (e.g. 456 assays of 0.31 mL)
Content:
141.6 mL of prepared reagent (e.g. 456 assays of 0.31 mL)
Shipping Temperature:
Ambient
Storage Temperature:
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
Acetic Acid
Assay Format:
Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
up to 30 μg/mL of acetic acid per assay
Limit of Detection:
10 mg/L (recommended assay format)
Reaction Time (min):
~ 15 min
Application examples:
Wine, beer, fruit and fruit juices, soft drinks, vinegar, vegetables, pickles, dairy products (e.g. cheese), meat, fish, bread, bakery products (and baking agents), ketchup, soy sauce, mayonnaise, dressings, paper (and cardboard), tea, pharmaceuticals (e.g. infusion solutions), feed and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Methods based on this principle have been accepted by EN, ISO, ICUMSA, IFU and MEBAK
The Acetic Acid analyser format test kit is suitable for the specific measurement and analysis of acetic acid (acetate) in beverages and food products.
See more of our acetic acid and organic acid test kits.
Advantages
No wasted ACS solution (stable suspension supplied)
PVP incorporated to prevent tannin inhibition
Very stable reagent when prepared for auto-analyser applications (> 3 days at 4oC)
Linear calibration up to 30 μg/mL of acetic acid in final reaction solution
Validated by the University of Wine, Suze la Rousse, France
Very competitive price (cost per mL of reagent)
All reagents stable for > 2 years after preparation
Document
The Acetic Acid analyser format test kit is suitable for the specific measurement and analysis of acetic acid (acetate) in beverages and food products.
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.
Refrigeration Series
● Dual compressors,Secop special compressors,air cooling (water cooling system is optional)
Silicone oil conducts heat,with uniform temperature and accuracy up to 0.1°C.Silicone oil has a wide temperature range,up to-100°C~+600°C.
● Shelf refrigeration system and cold trap refrigeration system are completely independent,without any switching,refrigeration temperature is lower and more stable.
Vacuum series
● Vacuum pump:German Pfeiffer anti-corrosion,anti-oil return function vacuum pump.(Vacuum pump can be selected according to user needs)
● Pumping rate:9m³/h~62m³/h,multiple specifications are optional,the ultimate vacuum can reach 2×10-3mbar,and the oil mist filter is standard.
● The vacuum pipelines are all high-vacuum stainless steel vacuum tubes, which can effectively prevent vacuum leakage and corrosion.
● The double anti-oil return device completely eliminates the damage and
equipment and samples.
● Automatic backfill air device,the system has a built-in High efficiency particulate air(HEPA)filter to ensure the complete cleanliness of backfill air.
● The vacuum stabilization system can stabilize the vacuum degree of the freeze-drying process through the micro-pass vacuum control valve to ensure that the samples will not be affected by excessive fluctuations in the vacuum degree.
● Condensed liquid collection and discharge system,automatically completes the collection and discharge of condensed liquid after freeze-drying.
Control SystemCharacteristic
● Control:Automatic/Manual
● Can store at least 100 independent freeze-drying programs,each program contains 32 program segments (Can be
customized according to user needs),each program segment corresponds to a processing stage (pre-freezing,main
drying,post-drying).and Include the following segment values:Cycles,shelf temperature,vacuum and safety pressure
● All the equipment can be recorded in real time and the corresponding freeze-drying curves and data tables can be generated after the end.The records of all data and curves comply with the corresponding regulations and standards.
● It has hierarchical management authority,hierarchical management allocation authority and usage process tracking authority
● Remote System
O Fully support 2G/4G/GSM/Wi-Fivarious connection modes
o Users can remotely view all data on the device and operate it
o Technicians can remotely perform maintenance and fault detection on equipment,and can remotely guide and train users
o Can remotely upgrade and change the system of the equipment
(Optional)Sufficient amount and time for the program to run itself
User function customization
Can be customized and modified according to user needs
Sterilization method
HzOz/steam sterilization
Note:”/”optional.Pilot models can be customized according to user needs
Document
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.