Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
D-Mannitol
Assay Format:
Spectrophotometer, Microplate, Auto-analyser
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
5 to 75 μg of D-mannitol per assay
Limit of Detection:
0.50 mg/L
Reaction Time (min):
~ 4 min
Application examples:
Wine, chewing gum, dietetic foods, candies, cosmetics, pharmaceuticals and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Novel method
The D-Mannitol test kit is suitable for the rapid and specific measurement and analysis of D-mannitol in food, beverages and other materials.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
All reagents stable for > 2 years after preparation
Simple format
Rapid reaction
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Extended cofactors stability
Suitable for manual, microplate and auto-analyser formats
Other Products
Plasma/Serum Exosome and Free-Circulating RNA Isolation Kits
Product Info
Document
Product Info
Overview
Isolate all sizes of RNA, including microRNA, irrespective of size or GC content, without bias.
Versatile sample input ranges
Isolate all sizes of free-circulating RNA, including microRNA
The purified exosomal RNA is free from any circulating RNA-binding proteins
No phenol extractions, Proteinase K treatment, nor carrier RNA
No time-consuming ultracentrifugation, filtration nor special syringes are required
No precipitation reagents, nor overnight incubation required
Concentrate isolated exosomal RNA and are free-circulating RNA into a flexible elution volume ranging from 50 µL to 100 µL
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
These kits provide a fast, reliable and convenient method to sequentially isolate and concentrate exosomal RNA as well as Free-Circulating RNA from different plasma/serum sample volumes. The purification is based on spin column chromatography that employs Norgen’s proprietary resin. These kits are designed to isolate all sizes of RNA, including microRNA as well as all sizes of the free-circulating protein-bound RNA, including microRNA. These kits provide a clear advantage over other available kits in that they do not require any special instrumentation, protein precipitation reagents, extension tubes, phenol/chloroform or protease treatments. Moreover, these kits allow the user to elute into a flexible elution volume ranging from 50 µL to 100 µL. The RNA isolated from the purified exosomes is free from any protein-bound circulating RNA and is of the highest integrity. Moreover, the free-circulating, protein-bound, RNA is free from any exosomal RNA. The purified RNA can be used in a number of downstream applications including real time PCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, and expression array assays.
Plasma/Serum Exosome and Free-Circulating RNA Isolation Mini Kit
For sample volumes ranging from 50 µL to 1 mL.
Plasma/Serum Exosome and Free-Circulating RNA Isolation Midi Kit
For sample volumes ranging from 1 mL to 4 mL.
Plasma/Serum Exosome and Free-Circulating RNA Isolation Maxi Kit
All sizes, including miRNA and small RNA (< 200 nt)
Elution Volume
50 – 100 µL
Time to Complete 10 Purifications
35 – 40 minutes
Average Yields*
Variable depending on specimen
*Please check page 5 of the product insert for the average yields and the common RNA quantification methods
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.
Important Note This kit is suitable for the purification of exosomes from fresh or frozen serum or plasma prepared from blood collected on either EDTA or Citrate. Plasma samples prepared from blood collected on heparin should not be used as heparin can significantly interfere with many downstream applications such as RT-PCR.
The Kit provides fast purification of high-quality DNA, RNA and Prote from cells, tissues, and yeast using silica-membrane spin columns with a binding capacity of 100ug RNA. There is no need for phenol/chloroform extractions and time-consuming steps such as CsCl gradient ultracentrifugation, or precipitation with isopropanol or LiCl are eliminated. RNA purified using the HiPure Total RNA Purification System is ready for applications such as RT-PCR, Northern blotting, poly A+ RNA (mRNA) purification, nuclease protection, and in vitro translation.
Details
Specifications
Features
Specifications
Main Functions
Co-isolation DNA and RNA /protein from a single sample (cells, soft tissue, plant sample)
Applications
SDS-PAGE electrophoresis and western blot, etc
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Culture cells, animal tissues, plant fungi, yeast, bacteria and other samples
Sample amount
Cultured cells: < 10^7Animal tissue: ≤ 20 mgPlant samples: ≤ 150 mgYeast cells: 2 x 10^6 – 5 x 10^7
Principle
The Kit isolates total RNA from up to 10 7 cells or 30 mg tissue. A short workflow enables RNAisolation with genomic DNA removal in less than 25 min. Samples are first lysed and homogenized. The lysate is passed through a DNA Mini column, ethanol is added to the flow-through, and the sample is applied to an RNA column. RNA binds to the membrane and contaminants are washed away. High-quality RNA is eluted in as little as 30 µl water using the Kit.
Advantages
High quality – high purity total RNA / DNA can be directly used in a variety of downstream applications
Fast – column method can complete the extraction of several samples in 30 minutes
Safe – no phenol chloroform extraction required
Simultaneous extraction- simultaneously isolate DNA and RNA from one sample
Kit Contents
Contents
R521102
R521103
Purification Times
50 Preps
250 Preps
HiPure DNA Mini Columns
50
250
HiPure RNA Mini Columns
50
250
2ml Collection Tubes
100
2 x 250
Buffer RLC
50 ml
200 ml
Buffer GW1*
22 ml
66 ml
Buffer RW1
50 ml
200 ml
Buffer RW2*
50 ml
3 x 50 ml
RNase Free Water
10 ml
30 ml
Elution Buffer
10 ml
30 ml
Buffer ALO(5%SDS)
10 ml
30 ml
Storage and Stability
HiPure Kit can be stored dry at room temperature (15–25°C) and are stable for at least 18 months under these conditions. During shipment, crystals or precipitation may form in the Buffer RLC. Dissolve by warming buffer to 37°C.
Document
The Kit provides fast purification of high-quality DNA, RNA and Prote from cells, tissues, and yeast using silica-membrane spin columns with a binding capacity of 100ug RNA. There is no need for phenol/chloroform extractions and time-consuming steps such as CsCl gradient ultracentrifugation, or precipitation with isopropanol or LiCl are eliminated. RNA purified using the HiPure Total RNA Purification System is ready for applications such as RT-PCR, Northern blotting, poly A+ RNA (mRNA) purification, nuclease protection, and in vitro translation.
Lyophilized format designed for room temperature shipping
Available in TaqMan format for analysis
Norgen’s Clostridium difficile TaqMan PCR Lyophilized Kit is designed for the detection of Clostridium difficile specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
Norgen’s Clostridium difficile TaqMan Lyophilized Probe/Primer and Control Set is designed for the detection of Clostridium difficile specific DNA in a real-time PCR based on the use of TaqMan® technology. The lyophilized format is designed to ship the kit at ambient temperature.
All kit components should be stored at -20°C upon arrival.
Once reconstituted, repeated thawing and freezing (>2 times) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Each kit is provided with 4 tubes of 2X PCR Master Mix and each tube is enough to run 25 reactions. It is not necessary to reconstitute all Master Mix tubes at once. The Master Mix tubes can be reconstituted as and when needed.
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.