Introduction
This product provides fast and easy methods for purification of total DNA for reliable PCR and Southern Blotting. Total DNA (e.g., genomic, viral, mitochondrial) can be purified from tissue and culture cells.
Details
Specifications
Features | Specifications |
Main Functions | Isolation total DNA from 2ml blood and 200mg tissue using Midi column |
Applications | PCR, southern bolt and virus detection, etc |
Purification method | Midi spin column |
Purification technology | Silica technology |
Process method | Manual (centrifugation or vacuum) |
Sample type | Tissue, cell, blood, saliva, swab, blood spot, semen and other clinical samples |
Sample amount | 0.2-2 ml |
Elution volume | ≥300μl |
Time per run | ≤80 minutes |
Liquid carrying volume per column | 4ml |
Binding yield of column | 1mg |
Principles
This product is based on silica column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, Nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Advantages
- High quality DNA – meet a variety of downstream applications, including PCR, qPCR, enzyme digestion, hybridization, etc.
- Fast – without separation of leukocytes, organic extraction or ethanol precipitation
- Simple – all nucleic acids can be obtained by direct digestion
- Wide applicability – handle a variety of liquid samples
Kit Contents
Contents | D311302 | D311303 |
Purification Times | 20 | 100 |
HiPure gDNA Midi Columns | 20 | 100 |
15ml Collection Tubes | 40 | 200 |
Buffer ATL | 50 ml | 250 ml |
Buffer AL | 50 ml | 250 ml |
Buffer GW1* | 22 ml | 110 ml |
Buffer GW2* | 12 ml | 50 ml |
RNase A | 20 mg | 90 mg |
Proteinase K | 100 mg | 440 mg |
Protease Dissolve Buffer | 10 ml | 30 ml |
Buffer AE | 20 ml | 120 ml |
Storage and Stability
Proteinase K, RNase A should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
Experiment Data
Purchase Guide
Name | CAT NO | Sample amount | Leukocyte protocol* | Colum type | Elutio volume | Average yield | Time per run |
HiPure Blood DNA Mini Kit | D3111 | 10-200μl | 1ml | 2ml column | ≥20μl | 5-9μg/200μl | ≤30 minutes |
HiPure Tissue&Blood DNA Midi Kit | D3113 | 0.2-2ml | 10ml | 1.5ml column | ≥300μl | 20-40μg/1m | ≤80 minutes |
HiPure Tissue&Blood DNA Maxi Kit | D3115 | 3 -10ml | 10ml | 15ml column | ≥700μl | 20-40μg/1m | ≤90 minutes |
HiPure Tissue&Blood DNA 96 Kit | D3117 | 1-200μl | 1ml | 96 well plate | 3-8μg/200μl |
*Note:Leukocyte protocol can be used when large volume whole blood samples need to be processed. Whole blood was treated with red blood cell lysate, and white blood cells were obtained by centrifugation before extraction
Select the right purification kit to get impactful results:
Ⅰ. Purchase guide of Magen kits based on sample
Ⅱ. Cross purchase guide for Magen kits vs Other brands
For any customized product or OEM service, please contact us.