
Thermal adapter for deep well plates, e.g., NEST 96 Deepwell Plate 2 mL. Compatible with the Opentrons Heater-Shaker Module.
Thermal adapter for deep well plates, e.g., NEST 96 Deepwell Plate 2 mL. Compatible with the Opentrons Heater-Shaker Module.

Thermal adapter for deep well plates, e.g., NEST 96 Deepwell Plate 2 mL. Compatible with the Opentrons Heater-Shaker Module.
Malaria is a mosquito-borne infectious disease and considered one of the leading causes of death in the world. Malaria is a fatal tropical disease that is caused by a parasite knows as Plasmodium. It is usually spread through the bite of an infected female mosquito. 300-500 million new infected cases are estimated every year with 1.5-2.7 million deaths worldwide. Most of the malaria-related deaths occur in sub-Saharan Africa. . Although blood is the sample most frequently used to make a diagnosis, both saliva and urine have been investigated as alternative, less invasive specimens
Malaria TaqMan PCR Kit, 100 reactions
Malaria TaqMan PCR Probe/Primer Set and Controls, 100 reactions
For research use only and NOT intended for in vitro diagnostics.
Figure 1 / 3
Click for expanded view
Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
| Component | Cat. TM34850 (100 preps) | Cat. TM34810 (100 preps) |
|---|---|---|
| MDx TaqMan 2X PCR Master Mix | 2 x 700 μL | – |
| Malaria Primer & Probe Mix | 280 μL | 280 μL |
| Malaria Positive Control | 150 μL | 150 μL |
| Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL |
| Product Insert | 1 | 1 |
Attogene’s Cadmium Lateral Flow Kit can be used to detect Cadmium in water samples at 5 ppb in the field.
Format: 10 test cassettes
Run Time: 15-30 minutes
Cadmium contamination is a serious worldwide environmental problem. As it is difficult to detoxify by chemical or biological methods, gradual Cadmium accumulation in the nervous and cardiovascular systems of the human body can subsequently cause serious diseases. Long-term health consequences of drinking cadmium-contaminated food and water include numerous negative health effects. Attogene’s Cadmium Lateral Flow test gives results conforming of 5ppb or greater. Using the supplied pipette, simply fill the vial with your water sample, place the water into the sample port and wait 15-30 minutes.
Format: 10 test cassettes
Run Time: 15-30 minutes
Detection: Cadmium in water samples at 5 ppb
MagPure Stool DNA Kit is specially designed for high throughput DNA extraction from stool samples. It can get high purity microbial DNA from stool samples (≤200mg). This kit is based on magnetic beads purification and unique inhibiting factors adsorption technology, no phenol-chloroform extraction or alcohol precipitation. It can adsorb humic acid and other inhibiting factors in the solution efficiently. DNA can be directly used for downstream applications such as PCR, Viral DNA testing, bacterial DNA testing, etc.
Specifications
| Features | Specifications |
| Main Functions | Isolation total DNA from 100-150mg stool samples |
| Applications | PCR, southern blot and enzyme digestion, etc. |
| Purification technology | Magnetic beads technology |
| Process method | Manual or automatic |
| Sample type | Stool |
| Sample amount | 100-150 mg |
| Elution volume | |
| Time per run |
This product is based on the purification method of high binding magnetic particles. The sample is lysed and digested under the action of lysate and Lysozyme. DNA is released into the lysate. After adding magnetic particles and binding solution, DNA will be adsorbed on the surface of magnetic particles, and impurities such as proteins will be removed without adsorption. The adsorbed particles were washed with washing solution to remove proteins and impurities, washed with ethanol to remove salts, and finally DNA was eluted by Elution Buffer.
Kit Contents
| Contents | D6364 |
| Purification Times | 400 Preps |
| MagPure Particles N | 14 ml |
| 2ml Bead Tubes | 400 |
| PVP-10 | 6 g |
| RNase A | 75 mg |
| Proteinase K | 180 mg |
| Protease Dissolve Buffer | 20 ml |
| Buffer ATL | 300 ml |
| Buffer PCI | 300 ml |
| Buffer MLE | 180 ml |
| Buffer GW1* | 132 ml |
| Elution Buffer | 60 ml |
Storage and Stability
MagPure Particles, RNase A and Proteinase K should be stored at 2-8°C upon arrival. However, short-term storage (up to 24 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
MagPure Stool DNA Kit is specially designed for high throughput DNA extraction from stool samples. It can get high purity microbial DNA from stool samples (≤200mg). This kit is based on magnetic beads purification and unique inhibiting factors adsorption technology, no phenol-chloroform extraction or alcohol precipitation. It can adsorb humic acid and other inhibiting factors in the solution efficiently. DNA can be directly used for downstream applications such as PCR, Viral DNA testing, bacterial DNA testing, etc.