endo-BCN-PEG2-NHS ester is aclick chemistry crosslinker containing an NHS ester group. The NHS ester can be used to label the primary amines (-NH2) of proteins, amine-modified oligonucleotides, and other amine-containing molecules. The BCN group is reactive with azide-tagged biomolecules. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Detail
endo-BCN-PEG2-NHS ester is aclick chemistry crosslinker containing an NHS ester group. The NHS ester can be used to label the primary amines (-NH2) of proteins, amine-modified oligonucleotides, and other amine-containing molecules. The BCN group is reactive with azide-tagged biomolecules. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Other Products
DNA Isothermal Rapid Amplification Kit Fluorescent Type
Product Info
Document
Product Info
Product Details
Kit Size:
48 Reactions
Product Name:
DNA Isothermal Rapid Amplification Kit Fluorescent Type
Kit Type:
DNA
Reaction Volume:
50 μL
Storage Temperature:
-20℃
Application:
Nucleic Acid Amplification
Type:
Fluorescent Type
Reaction Time:
20mins
High Light:
20mins home test kit
,
DNA home test kit
,
48 Reactions home dna test kit
Payment & Shipping Terms
Minimum Order Quantity
48T
Price
3.8$/T
Packaging Details
16T/bag,48T/box
Delivery Time
6days
Payment Terms
T/T,Paypal
Supply Ability
100000T/Month
Product Description
DNA Isothermal Rapid Amplification Kit(Fluorescent Type)Guide Manual
Buffer system mainly for stabilizing protein/enzyme and performance
B buffer
0.15ml
1 Tube
Mainly activated systems such as magnesium ions
Positive control template
0.1ml
1 Tube
Mainly the positive plasmid template is used to test the effectiveness of the kit
Positive control primer mix
0.06ml
1 Tube
Mainly the primer combination of the positive control template
Reagent Guide Manua
16T/bags,48T/Box
3 bags
Reagent technology of protein/enzyme system: freeze-dried powder, freeze-dried microspheres
Principle overview
This kit is based on a room temperature and constant temperature nucleic acid rapid amplification technology: at room temperature and constant temperature, the recombinase and primer form the protein/single-stranded nucleotide complex Rec/ssDNA, with the help of auxiliary proteins and single-stranded binding protein SSB , invade the double-stranded DNA template; form a D-loop region at the invasion site, and start scanning the DNA double-strands; after finding the target region complementary to the primer, the Rec/ssDNA complex disintegrates, and the polymerase also binds to The 3′ end of the primer initiates chain extension. This kit relies on the action of exonuclease at 39 ºC, adding specific molecular probes designed based on the template, and using fluorescence monitoring equipment to achieve real-time monitoring of the amplification process of the target fragment.
Primer design
It is recommended to use primers with a length of 30-35 bp. Primers that are too short will affect amplification speed and detection sensitivity; primers are designed to avoid the formation of secondary structures that affect amplification; the amplicon length is recommended to be 150-300 bp, usually no more than 500 bp.
Fluorescent probe design
The probe sequence does not overlap with the specific primer recognition site, is 46-52 nt in length, and the sequence avoids palindromic sequences, internal secondary structures, and continuous repeated bases. The probe has four modification sites: the middle position ≥ 35 nt from the 5′ end is labeled with a dSpacer (tetrahydrofuran, THF) as the recognition site for exonuclease; the upstream of the THF site is labeled with a fluorescent group, and the downstream Label a quenching group, the distance between the two groups is 2-4 nt; THF is ≥15 nt from the 3′ end, and the 3′ end is labeled with a modifying group, such as an amine group, a phosphate group or a C3-Spacer.
Product features and advantages:
This kit has the advantages of high sensitivity, strong specificity,and short reaction time (only 20 minutes), and the reaction groups are in dry powder state, which is easy to operate and easy to store.
It can be applied to various brands of fluorescence quantitative PCR instruments, constant temperature fluorescence amplification instruments and other fluorescence detection equipment.
Document
This kit is based on a room temperature and constant temperature nucleic acid rapid amplification technology: at room temperature and constant temperature, the recombinase and primer form the protein/single-stranded nucleotide complex Rec/ssDNA, with the help of auxiliary proteins and single-stranded binding protein SSB , invade the double-stranded DNA template; form a D-loop region at the invasion site, and start scanning the DNA double-strands; after finding the target region complementary to the primer, the Rec/ssDNA complex disintegrates, and the polymerase also binds to The 3′ end of the primer initiates chain extension. This kit relies on the action of exonuclease at 39 ºC, adding specific molecular probes designed based on the template, and using fluorescence monitoring equipment to achieve real-time monitoring of the amplification process of the target fragment.
This product provides fast and easy methods for purification of total DNA for reliable PCR and Southern blotting. Total DNA(e.g., genomic, viral, mitochondrial) can be purified from small volume of blood, tissue and dry blood spots.
Details
Specifications
Features
Specifications
Main Functions
Isolation total DNA from 1-10μl blood, <10mg tissue, urine, blood stain, seminal stain
Applications
PCR, southern bolt and virus detection, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Animal tissues, blood stain, urine, seminal stain and various forensic samples
Sample amount
Blood:1-100μl, Tissue:<10mg
Elution volume
Time per run
Liquid carrying volume per column
Binding yield of column
Principle
This product is based on silica Column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, nucleic acid was finally eluted with low-salt buffer (10mmTris, pH9.0, 0.5mm EDTA).
Advantages
Fast – several samples can be extracted in 20 minutes (after digestion)
High purity – purified DNA can be directly used in various downstream applications
High recovery – DNA can be recovered at the level of PG
Good repeatability – silica technology can obtain ideal results every time
Kit Contents
Contents
D312502
D312503
Purification Times
50 Preps
250 Preps
Buffer ATL
15 ml
60 ml
Buffer AL
15 ml
60 ml
Buffer GW1*
22 ml
66 ml
Buffer GW2*
20 ml
2 x 50 ml
Carrier RNA
310 μg
2 x 310 µg
Proteinase K
24 mg
120 mg
Protease Dissolve Buffer
1.8 ml
10 ml
Buffer AE
15 ml
60 ml
HiPure DNA Mini Columns I
50
2 x 125
2 ml Collection Tubes
100
5 x 100
Storage and Stability
Carrier RNA and Proteinase K should be stored at 2–8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15–25°C) does not affect its performance. The remaining kit components can be stored dry at room temperature (15–25°C) and are stable for at least 18 months under theseconditions.
Experiment Data
Document
This product provides fast and easy methods for purification of total DNA for reliable PCR and Southern blotting. Total DNA(e.g., genomic, viral, mitochondrial) can be purified from small volume of blood, tissue and dry blood spots.
GL21MC high speed refrigerated centrifuge Application:
Widely used in the area of animal and plant molecular biology, cell biology, clinical applications, bio-engineering, mass preparation and blood, protein precipitation, Separating the biology, viruses, sub-cell, cell and the chemicals in the cell.
Features:
1.Brushless frequency motor in great torque, free maintenance, no carbon dust pollution, quick in speed up and down.
2. Flexible axle driven system which drive the rotor directly, smooth in operation, low noise and small vibration. 3.Import compressors fluorine free, double cycle cooling, cold and hot alternating easily, free environment pollution and precise in temperature control.. 4. Microprocessor control system, the 10 inches LCD display indicates all the parameters in running, 5. There are more than 20 kinds of rotors for your choice, especial the continuous rotors which help you purify a large number of test solution continuously. 6. There are 30 kinds of program and 10 kinds of accelerating and decelerating speed for your choice. 7.ω2t centrifugation is allowed, which make you have the ideal centrifugation result. 8. 20 kinds of rotors for your choice, especial the continuous rotor help you purify a large amount of test solution continuously. 9. Automatically electric lid lock, super speed, over temperature protection and imbalance protection. 10. The centrifuge body is made of high quality steel, safe and reliable. 11. 3 tiers protection steel cover.
Technical parameters:
Max speed
21000r/min
Max RCF
46140*g
Time range
1~99H59min
Speed accuracy
±50r/min
capacity
6*500ml
Noise
≦65dBA
Weight
235KG
Dimension
865*728*1240mm
Packaged weight
285KG
Packaged dimension
1000*850*1510mm
Temperature range
-20~40℃
Temperature accuracy
±1℃
Power
AC110/220V, 50-60HZ,35A
Rotor identification
Automatic identification
Package
wooden box
Matched Rotors for GL21MC:
Order No.
Rotor
Max speed (r/min)
Max capacity (ml)
Max RCF (*g)
30108
Fixed rotor
21000
12*10ml
44440
30117
Fixed rotor
20000
16*10ml
46140
30111
Fixed rotor
20000
6*50ml
44700
30118
Fixed rotor
20000
8*30/20ml
42040
30119
Fixed rotor
15000
8*50ml
27540
30112
Fixed rotor
15000
6*70ml
25480
30120
Fixed rotor
12000
8*100ml
19610
30121
Fixed rotor
11000
4*300ml
18120
30122
Fixed rotor
10000
6*300ml
15730
30123
Fixed rotor
10000
6*500ml
18340
30128
Continuous centrifugal rotor
17000
1000ml
31390
30129
Continuous centrifugal rotor
14000
1800ml
21710
30130
Continuous centrifugal rotor
8000
3000ml
9450
30131
Continuous centrifugal rotor
8000
1800ml
8600
30132
Interval rotor
17000
1000ml
31390
30133
Interval rotor
12000
1200ml
19350
30134
Interval rotor
10000
3000ml
14890
30135
Vertical rotor
20000
16*5ml
38340
Vertical rotor
18000
8*30ml
32650
30180
Swing rotor
15000
4*5ml
21670
30181
Swing rotor
13000
4*30ml
23580
30182
Swing rotor
10000
4*50ml
16240
30694
Bucket rotor
4000
4*4*96holes
2840
30696
Swing rotor
4000
4*500ml
3380
Document
GL21M max. capacity can hold 800ml bottles 4pcs, max speed over 20000rpm
Model: