Sixteen discrete fragments ranging from 100 bp to 5000 bp
Higher intensity reference bands at 500 bp and 1000 bp
The Norgen FullRanger 100 bp DNA Ladder is prepared to ensure quality and batch-to-batch consistency. Our FullRanger contains sixteen discrete fragments ranging from 100 bp to 5000 bp with higher intensity reference bands at 500 bp and 1000 bp. This Ladder is ideal for accurate visual determination in both large and small cloning applications.
Contents 1mL of premixed DNA ladder (0.5µg/10µL) in loading buffer (10mM EDTA, 10% glycerol, 0.015% bromophenol blue, and 0.17% SDS).
FullRanger 100 bp DNA Ladder (Cat# 11800) – 100 loads
Ladder Properties: • Sixteen discrete bands, ranging from 100 bp to 5000 bp • Higher intensity reference bands at 500 bp and 1000 bp
Fragment
Size (bp)
Mass (ng)
1
5000
55
2
4000
44
3
3000
33
4
2500
28
5
2000
22
6
1500
17
7
1000
50
8
900
35
9
800
31
10
700
43
11
600
24
12
500
56
13
400
16
14
300
22
15
200
15
16
100
11
Recommended Use:
Mix thoroughly. For best results, load 10µL of DNA ladder per well. For precise mass determination with a densitometer, stain gel after electrophoresis using 0.5µg/mL ethidium bromide for 30-40 minutes. The table above shows the size and mass for each band based on 10µL ladder per well.
Storage:
Stable at room temperature. For longer term storage, -20°C is recommended.
This ladder was standardized using 10µL of DNA per lane on a 0.8 cm thick, 13 x 15 cm, 1.0% agarose gel run in TAE buffer.
Other Products
IST-110 Gas PermASealTM Heat Sealing Film
Product Info
Document
Product Info
Overview
Non-woven gas permeable seal that limits evaporation. The seal is peelable, pierceable; suitable for cell culture and seed & insect storage too.
Heat sealing offers a 100% effective method for plate sealing for a complete seal integrity, as well as being quick and cost effective
Our Gas PermASeal Heat Seal is made from a non-woven material and is designed for use in cell culture, due to its porous nature
The seal is compatible with polypropylene and polystyrene
It can be removed by peeling, or it can be pierced with a pipette tip manually, using a liquid handling robot.
Gas PermASeal Heat Seal can be utilized for effective overnight incubations, during which it demonstrates significant reductions in evaporation compared to lids
It can also be used for insect and seed storage as it enables gas exchange, whilst providing an inert surface with no adhesive to interfere with the well contents
This seal is available as sheets, for use with manual and semi-automated sealers, such as our HeatASeal 500 Sealing Machine
Also available in multiple roll formats compatible with specified automated heat sealers, such as our Wasp or Chameleon XT
Document
Non-woven gas permeable seal that limits evaporation. The seal is peelable, pierceable; suitable for cell culture and seed & insect storage too.
HiPure RNA Clean Up Kit provides a rapid and easy method for the purification and concentrate RNA from enzymatic reactions or for desalting the RNA samples. RNA purified using HiPure RNA Clean Up Kit is ready for all downstream applications such as RT-PCR, Northern blotting, mRNA purification, nuclease protection, and in vitro translation.
Details
Specifications
Features
Specifications
Main Functions
Purification and concentration of RNA(mRNA>200nt or miRNA)from transcription products, DNase cleavage products, labeled products, and crude RNA products
Applications
Sequencing, ligation, enzyme digestion, RT-PCR, labeling, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Crude RNA, enzymatic reaction solution
Sample amount
≤100μl
Recovery
90%
Elution volume
≥15μl
Time per run
≤15 minutes
Liquid carrying volume per column
800μl
Binding yield of column
100μg
Principle
The HiPure system uses a simple bind-wash-elute procedure. Binding buffer is added directly to the sample or other enzymatic reaction, and the mixture is applied to the column. Nucleic acids adsorb to the silica membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure RNA is eluted with a small volume of low-salt buffer provided or water, ready to use in all subsequent applications.
Advantages
High recovery – recovery of RNA up to 90%
Low elution volume – the elution volume can be as low as 15µl
Fast – only 10 minutes for recovery by using column method
General – suitable for various crude RNA products
Wide range of fragment recovery:(>25nt RNA)
Kit Contents
Contents
R214402
R214403
Purification Times
50 Preps
250 Preps
Buffer GXP
30 ml
120 ml
Buffer RW2
20 ml
2 x 50 ml
RNase-Free Water
20 ml
60 ml
HiPure RNA Mini Columns I
50
250
2 ml Collection Tubes
50
250
Storage and Stability
The Kit can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions. The entire kit can be stored at 2-8°C, but in this case buffers should be redissolved before use. Make sure that all buffers are at room temperature when used.
Document
HiPure RNA Clean Up Kit provides a rapid and easy method for the purification and concentrate RNA from enzymatic reactions or for desalting the RNA samples. RNA purified using HiPure RNA Clean Up Kit is ready for all downstream applications such as RT-PCR, Northern blotting, mRNA purification, nuclease protection, and in vitro translation.
The series of DNA Size Selection Kits (Magnetic Beads) were developed for DNA size selection using magnetic beads. A total of 11 kits are available, with different selection ranges spanning from 50 bp to over 10 kb. The kits provide a simple and quick approach for the enrichment of a specific range of DNA fragments. The kit workflow allows double-sided or single-sided size selection for specific size cutoffs.
Gel images of different ranges of size selection. Sheared human genomic DNA was used as input.
.
DNA size selection is a selective capture of DNA fragments of a specific range of size for next-generation sequencing (NGS) library preparations, PCR, ChIP assay, DNA ligations, endonuclease digestions, adapter removal, and other genomics and molecular biology applications. DNA size selection is preferred after NGS library prep in most of the cases. The NGS library preparation is related to the quality of the sequencing data. Precise NGS library size selection can increase sequencing efficiency, improve data quality, and reduce costs.
There are two types of sequencing technologies: short-read sequencing and long-read sequencing. Short-read sequencing uses DNA libraries that contain small insert DNA fragments of similar sizes, usually several hundred base pairs. The sequencing efficiency can be improved if the DNA size selection is in the right range. Cat.# 20104S and 20104L are the best kits for NGS library size selection of illumina paired-end 100 (PE100) sequencing with 100-200 bp library inserts; Cat.# 20105S and 20105L are the best kits for NGS library size selection of illumina paired-end 150 (PE150) sequencing with 150-300 bp library inserts; and Cat.# 20106S and 20106L are the best kits for NGS library size selection of illumina paired-end 300 (PE300) sequencing with 300-600 bp library inserts.
Long-read sequencing uses a large DNA fragment as input and makes very long reads. Usually, library size selection is preferred to remove smaller fragments. Cat.# 20110S and 20110L are the best kits for long-read sequencing size selection with DNA sizes >5 kb, and Cat.# 20111S and 20111L are the best kits for long-read sequencing size selection with DNA sizes >10 kb.
The magnetic beads technology uses paramagnetic particles, also known as SPRI (Solid Phase Reversible Immobilization) beads, to bind DNA reversibly and selectively. DNA fragments can be size-selected and purified by changing the properties of the magnetic beads or SPRI beads. The magnetic beads can easily separate the beads-binding DNA from the contaminants and unwanted components in the samples. The samples after DNA size selection are free of contaminants such as buffer components, enzymes, proteins, salts, dNTPs, primers, and adapters. Our proprietary magnetic beads reagents improve yield, selectivity, and reproducibility.
Specific DNA fragments at a certain length range can be purified simply using magnetic separation with different beads components, avoiding tedious and time-consuming gel extraction and column-based purification. The magnetic beads method is popular for common DNA size selection, including library size selection. The first beads-binding step, referred to as the right-side clean-up, removes large DNA fragments. The large DNA fragments are bound to the beads and are discarded. The desired DNA fragments in the supernatant are transferred to a new well, and new beads are added to the supernatant for the second beads-binding, referred to as the left-side clean-up. The double-size selected DNA fragments are eluted after ethanol rinsing.
DNA size selection with dual clean-ups.
.
A single clean-up is needed for DNA size selection with large fragments. In this case, only the large DNA fragments are bound to the beads. The selected larger DNA fragments are eluted after ethanol rinsing.
DNA size selection with single clean-up for >5 kb and >10 kb DNA.
.
Features of DNA size selection and library size selection
High specificity and high recovery of size selection
11 selection ranges are available, including 5 ranges for NGS library size selection
50-100 bp
100-200 bp
200-500 bp
250-350 bp: ideal for illumina PE100 sequencing
300-450 bp: ideal for illumina PE150 sequencing
450-750 bp: ideal for illumina PE300 sequencing
500-1000 bp
1-3 kb
1-5 kb
>5 kb: ideal for long-read sequencing
>10 kb: ideal for long-read sequencing
Fast and simple
20-min protocol
No gel purification required
No columns required
No centrifugation required
Efficient removal of contaminants and unwanted components