All reagents stable for > 2 years after preparation
Only enzymatic kit available
Simple format
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Other Products
IVD3182 HiPure Circulating DNA Kit
Product Info
Document
Product Info
Introduction
Free-circulating nucleic acids, such as tumor-specific extracellular DNA fragments and mRNAs in the blood or fetal nucleic acids in maternal blood, are present in serum or plasma usually as short fragments, <1000bp (DNA). HiPure Circulating DNA Midi Kit enables efficient purification of these circulating nucleic acids from human plasma, serum, or urine. The extracted products can be used for clinical in vitro detection.
Details
Specifications
Features
Specifications
Main Functions
Isolation circulating DNA from 1-5ml plasma, serum, body fluids using vacuum protocol
Applications
qPCR, liquid or solid chip analysis, hybridization and SNP detection, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (vacuum)
Sample type
Serum, plasma and other cell-free fluid samples
Sample amount
1-5ml
Elution volume
≥50μl
Time per run
≤60 minutes
Liquid carrying volume per column
4ml
Binding yield of column
1mg
Principle
This product is based on silica Column purification. The sample is lysed and digested with lysate and protease, DNA is released into the lysate. Transfer to an adsorption column. Nucleic acid is adsorbed on the membrane, while protein is not adsorbed and is removed with filtration. After washing proteins and other impurities, Nucleic acid was finally eluted with low-salt buffer.
Advantages
High yield – most optimal process, free DNA (>50bp) can be obtained to the maximum extent
High concentration – low elution volume, ensuring high nucleic acid concentration
High purity – low alcohol binding method, completely removing inhibitor and protein pollution
High recovery – DNA can be recovered at thelevel of PG by silica gel column purification
Kit Contents
Contents
IVD3182
Purification Times
50
Buffer ACL
250 ml
Buffer ACB*
300 ml
Buffer DCW1*
22 ml
Buffer DCW2*
10 ml
Proteinase K
540 mg
Protease Dissolve Buffer
30 ml
Carrier RNA
110 μg
Nuclease Free Water
20 ml
HiPure CFDNA Mini Columns
50
2 ml Collection Tubes
100
Extender Tube
50
Vac-Connector
50
Storage and Stability
Proteinase K, Carrier RNA should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions. The entire kit can be stored at 2-8°C, but in this case buffers should be redissolved before use. Make sure that all buffers are at room temperature when used.
Experiment Data
Document
Free-circulating nucleic acids, such as tumor-specific extracellular DNA fragments and mRNAs in the blood or fetal nucleic acids in maternal blood, are present in serum or plasma usually as short fragments,
The HiPure Plasmid EF Mini Kit combine the power of HiPure technology with Magen’s innovative endotoxin removal technology to deliver high-quality plasmid DNA with low endotoxin levels foruse in eukaryotic transfection, and in vitro experiments. The HiPure plasmid endo-free system uses a specially formulated buffer that prevents endotoxin molecules from binding to the surface of the HiPure matrix. Endotoxin contamination lowers transfection efficiencies for endotoxin sensitive celllines. For gene therapy, endotoxin contamination should be of major concernsince endotoxins have the potential to cause fever, endotoxin shock syndrome, and interfere with in vitro transfection into immune cells.
Details
Specifications
Features
Specifications
Main Functions
Isolation up to 80µg endotoxin-free plasmid DNA from 5-15ml bacterial culture. Recommend for low copy vector, Thoroughly remove RNA
Applications
Cell transfection, animal injection, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Low copy plasmid vector
Sample amount
5-15ml LB
Yield
10-70μg
Elution volume
≥75μl
Time per run
≤40 minutes
Liquid carrying volume per column
800μl
Binding yield of column
70μg
Principle
The HiPure Plasmid procedure is based on alkaline lysis of bacterial cells followed by adsorption of DNA onto silica in the presence of high salt. The unique silica membrane used in the kit completely replaces glass or silica slurries for plasmid DNA minipreps. The procedure consists of 3 basic steps: Preparation and clearing of a bacterial lysate by alkaline method,then transfer the supernatant to column to bind DNA. After washing proteins and other impurities, nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Advantages
High purity – purified plasmid can be directly used in sequencing, enzyme digestion and PCR, etc.
Fast – silica gel column purification is much faster than ion exchange
High yield – up to 70μg plasmid can be binded in one column
Low endotoxin content – the obtained plasmid can be directly used in cell transfection and animal injection
Kit Contents
Contents
P115402
P115403
Purification Times
50 Preps
250 Preps
RNase A
5 mg
20 mg
Buffer P1
30 ml
140 ml
Buffer P2
30 ml
140 ml
Buffer LEN3
15 ml
70 ml
Buffer LN4
50 ml
250 ml
Buffer LN5
30 ml
140 ml
Buffer PW1
30 ml
140 ml
Buffer PW2
12 ml
50 ml
Elution Buffer
15 ml
30 ml
HiPure DNA Mini Columns III
50
250
2 ml Collection Tubes
50
250
Storage and Stability
The kit components can be stored dry at room temperature (15–25°C) and are stable for at least 18 months under these conditions. If any precipitates form in the buffers, warm at 37℃ to dissolve. After addition of RNase A,Buffer P1 is stable for 6 months when stored at 2–8°C.
The HiPure Plasmid EF Mini Kit combine the power of HiPure technology with Magen’s innovative endotoxin removal technology to deliver high-quality plasmid DNA with low endotoxin levels foruse in eukaryotic transfection, and in vitro experiments. The HiPure plasmid endo-free system uses a specially formulated buffer that prevents endotoxin molecules from binding to the surface of the HiPure matrix. Endotoxin contamination lowers transfection efficiencies for endotoxin sensitive celllines. For gene therapy, endotoxin contamination should be of major concernsince endotoxins have the potential to cause fever, endotoxin shock syndrome, and interfere with in vitro transfection into immune cells.
GL21MC high speed refrigerated centrifuge Application:
Widely used in the area of animal and plant molecular biology, cell biology, clinical applications, bio-engineering, mass preparation and blood, protein precipitation, Separating the biology, viruses, sub-cell, cell and the chemicals in the cell.
Features:
1.Brushless frequency motor in great torque, free maintenance, no carbon dust pollution, quick in speed up and down.
2. Flexible axle driven system which drive the rotor directly, smooth in operation, low noise and small vibration. 3.Import compressors fluorine free, double cycle cooling, cold and hot alternating easily, free environment pollution and precise in temperature control.. 4. Microprocessor control system, the 10 inches LCD display indicates all the parameters in running, 5. There are more than 20 kinds of rotors for your choice, especial the continuous rotors which help you purify a large number of test solution continuously. 6. There are 30 kinds of program and 10 kinds of accelerating and decelerating speed for your choice. 7.ω2t centrifugation is allowed, which make you have the ideal centrifugation result. 8. 20 kinds of rotors for your choice, especial the continuous rotor help you purify a large amount of test solution continuously. 9. Automatically electric lid lock, super speed, over temperature protection and imbalance protection. 10. The centrifuge body is made of high quality steel, safe and reliable. 11. 3 tiers protection steel cover.
Technical parameters:
Max speed
21000r/min
Max RCF
46140*g
Time range
1~99H59min
Speed accuracy
±50r/min
capacity
6*500ml
Noise
≦65dBA
Weight
235KG
Dimension
865*728*1240mm
Packaged weight
285KG
Packaged dimension
1000*850*1510mm
Temperature range
-20~40℃
Temperature accuracy
±1℃
Power
AC110/220V, 50-60HZ,35A
Rotor identification
Automatic identification
Package
wooden box
Matched Rotors for GL21MC:
Order No.
Rotor
Max speed (r/min)
Max capacity (ml)
Max RCF (*g)
30108
Fixed rotor
21000
12*10ml
44440
30117
Fixed rotor
20000
16*10ml
46140
30111
Fixed rotor
20000
6*50ml
44700
30118
Fixed rotor
20000
8*30/20ml
42040
30119
Fixed rotor
15000
8*50ml
27540
30112
Fixed rotor
15000
6*70ml
25480
30120
Fixed rotor
12000
8*100ml
19610
30121
Fixed rotor
11000
4*300ml
18120
30122
Fixed rotor
10000
6*300ml
15730
30123
Fixed rotor
10000
6*500ml
18340
30128
Continuous centrifugal rotor
17000
1000ml
31390
30129
Continuous centrifugal rotor
14000
1800ml
21710
30130
Continuous centrifugal rotor
8000
3000ml
9450
30131
Continuous centrifugal rotor
8000
1800ml
8600
30132
Interval rotor
17000
1000ml
31390
30133
Interval rotor
12000
1200ml
19350
30134
Interval rotor
10000
3000ml
14890
30135
Vertical rotor
20000
16*5ml
38340
Vertical rotor
18000
8*30ml
32650
30180
Swing rotor
15000
4*5ml
21670
30181
Swing rotor
13000
4*30ml
23580
30182
Swing rotor
10000
4*50ml
16240
30694
Bucket rotor
4000
4*4*96holes
2840
30696
Swing rotor
4000
4*500ml
3380
Document
GL21M max. capacity can hold 800ml bottles 4pcs, max speed over 20000rpm Model: GL21M