Description
Specifications
Clone | IHC005 |
Source | Mouse Monoclonal |
Positive Control | Tonsil |
Dilution Range | 1:200 |
PAX-5 is a member of the paired box (PAX) family of transcription factors, which are key regulators in early development. The PAX-5 gene encodes the B-cell lineage specific activator protein (BSAP), whose expression is limited to early stages of B-cell differentiation. Anti-PAX-5 is useful in differentiating between classic Hodgkin’s lymphoma versus multiple myeloma and solitary plasmacytoma, as the protein is expressed in mature and precursor B-cell non-Hodgkin’s lymphomas/leukemias while being absent from the other two conditions. Diffuse large B-cell lymphomas are positive for PAX-5, with the exception of those with terminal B-cell differentiation, and T-cell neoplasms do not stain with Anti-PAX-5.
Clone | IHC005 |
Source | Mouse Monoclonal |
Positive Control | Tonsil |
Dilution Range | 1:200 |
This kit provides a fast and simple procedure for the effective depletion of major serum proteins including albumin, α-antitrypsin, transferrin and haptoglobin from serum and plasma samples. Such abundant proteins usually obscure less abundant proteins in gel electrophresis making them difficult to visualize and recover. The kit reduces sample complexity to allow for convenient investigation of less abundant proteins. In other applications such as mass spectroscopy, fractionating abundant proteins improves the resolution of less abundant proteins. The kit is ‘generic’ in that it is not antibody-based and can thus be used to deplete abundant proteins from any starting material – human or various other animals – making it more versatile, flexible and affordable than other kits. Resulting proteins are ready for a range of applications including 2D gel electrophoresis, SDS-PAGE, Mass Spectrometry, Protein microarrays, DIGE (Difference Gel Electrophoresis) and more.
Figure 1 / 2
Click for expanded view
Kit Specifications | |
Maximum Column Capacity | 500 μg |
Minimum Column Capacity | 200 μg |
Minimum Elution Volume | 30 μL |
Time to Process 10 Samples | 30 minutes |
Storage Conditions
All solutions should be kept tightly sealed and stored at room temperature. Once opened, the solutions should be stored at 4°C. This kit is stable for 2 years after the date of shipment.
Component | Cat. 17300 (25 preps) |
---|---|
Wash Solution G | 125 mL |
Elution Buffer C | 8 mL |
Protein Neutralizer | 4 mL |
Spin Columns | 25 |
Collection Tubes | 25 |
Elution Tubes (1.7 mL) | 25 |
Product Insert | 1 |
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
The series of nucleic acid columns produced by Magen Biotech are based on carefully selected imported glass fiber membranes (GF/B, GF/D, GF/F). Columns production processes such as polypropylene injection molding materials, injection molding process, and downstream membrane packing and compression rings are strictly controlled. This is to ensure that the column has extremely high adsorption capacity and long-term stability. Compared with conventional products on the market, Magen’s columns are with varieties, and binding rate will not change when stored at room temperature for 4 years.
Specifications
Features | Specifications |
Recommended application | gDNA maxi yield preparation, total RNA maxi preparation |
Preservation conditions | Room temperature |
Stability | Up to 4 years |
Filter membrane | High quality glass fiber filter GF/B, 4 layers |
Membrane aperture | 1.0μm |
Maximum binding yield of plasmid | 500 μg |
Maximum yield of alcohol mediated binding | 5 mg |
gDNA or RNA yield (>30%ethanol) | Up to 5mg |
Single liquid carrying capacity of column | 20 ml |
Minimum elution volume | 800 μl |
Withstand centrifugal force | 3,000~5,000 x g |
Centrifuge | Low speed centrifuge for 50mlcentrifuge tubes, >3000 x g, swing-out Rotor |
Adsorption Mechanism
Based on the negatively charged DNA skeleton, it has a high affinity for positively charged glass fibers. In high salt and ethanol solutions, DNA/RNA binds to glass fiber and interacts with hydrophilic matrix on silica through hydrogen bond. DNA/RNA is tightly bound. All pollutants can be removed by washing solution. At high salt concentration, nucleic acids selectively bind to silica gel membrane, while other pollutants, mainly proteins, are removed by membrane washing.
Ordering information
CAT.No. | Product Name | Package |
C13122 | HiPure gDNA Maxi Column (4 x GF/B)with 50ml Collection Tubes | 100/Bag |
Item No. | Product Name | Membrane type/number of layers | Collection tubes | Plasmid DNA binding capacity (Physical adsorption) | gDNA/RNA binding capacity (Alcohol-mediated adsorption) | Minimum Elution volume | Liquid volume capacity |
C13010 | HiPure DNA Nano Column | 2 layers GF/F | 2ml without cap | 5μg | 20μg | 10μl | 700μl |
C13011 | HiPure DNA Micro Column | 3 layers GF/F | 2ml without cap | 10μg | 50μg | 15μl | 700μl |
C13100 | HiPure DNA Mini Column I | 2 layers GF/B | 2ml without cap | 15μg | 100μg | 30μl | 700μl |
C13110 | HiPure DNA Mini Column II | 4 layers GF/B | 2ml without cap | 35μg | 200μg | 50μl | 800μl |
C13111 | HiPure RNA Mini Column | 3 layers GF/B | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
C13112 | HiPure Viral Mini Column | 3 layers GF/F | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
C13113 | HiPure CFDNA Mini Column | 3 layers GF/F,1 layer GF/B | 2ml without cap | 30μg | 200μg | 30μl | 800μl |
C13120 | HiPure DNA Midi Column | 4 layers GF/B | 15ml Centrifuge tube | 125μg | 1mg | 500μl | 4ml |
C13121 | HiPure DNA Midi Column III | 8 layers GF/B | 15ml Centrifuge tube | 250μg | 1mg | 500μl | 4ml |
C13122 | HiPure DNA Maxi Column | 4 layers GF/B | 50ml Centrifuge tube | 500μg | 5mg | 1000μl | 20ml |
C13123 | HiPure DNA Maxi Column III | 8 layers GF/B | 50ml Centrifuge tube | 1mg | 5mg | 1000μl | 20ml |
C13124 | HiPure DNA Maxi Column C | 8 layers GF/B | 50ml high speed Centrifuge tube | 1mg | 5mg | 700μl | 12ml |
C13130 | HiPure DNA Plate | 2 layers GF/F | 1.6ml Plate | 30μg | 100μg | 80μl | 900μl |
C13131 | HiPure gDNA Plate | 2 layers GF/B | 1.6ml Plate | 30μg | 100μg | 80μl | 900μl |
Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
Description
The FluoroStain™ Protein Fluorescent Staining Dye (Red, 1000×) is designed to substitute the common Coomassie Blue protein staining method, offering greater sensitivity and ease of operation. Unlike Coomassie Blue stain, the FluoroStain Protein Fluorescent Staining Dye binds to protein with high specificity, making destaining process an option rather than a requirement. With further reduction of background signals via destaining process, the FluoroStain™ is capable of achieving detection level parallel to silver staining without specialized imaging equipment, making it one of the most sensitive dyes available. In addition to its remarkable sensitivity, the FluoroStain™ Protein Fluorescent Staining Dye (Red, 1000×) brings a more reliable and safer user experience, since the stained gel can be visualized with blue-light illumination, avoiding the risk of skin/ eye damage caused by UV light. For best result, we suggest using B-BOX™ Blue Light LED epi-illuminator to visualize and analyze the gel stained with FluoroStain Protein Fluorescent Staining Dye (Red, 1000×). The FluoroStain™ Protein Fluorescent Staining Dye is compatible to the analysis of mass spectra, i.e. LC-MS/MS, MALDI-TOF, etc.
Spectral Characteristics
When it is bound with bovine serum albumin (BSA), the fluorescent emission of FluoroStain Protein Fluorescent Staining Dye can be excited by UV and blue light sources, with excitation peaks around 369 and 517 nm and emission at 605 nm. In absence of BSA, FluoroStain Protein Fluorescent Staining Dye shows ignorable fluorescence as compared with protein-bound form, therefore giving a clear background for photographic analysis.
These spectral characteristics made this fluorescent dye compatible with a wide variety of gel reading facilities, including UV/ blue light epi- and transilluminator, argon laser and mercury-arc lamp excitation gel scanners.
Storage
Protected from light
-20°C for 24 months
The FluoroStain™ Protein Fluorescent Staining Dye (Red, 1000×) is designed to substitute the common Coomassie Blue protein staining method, offering greater sensitivity and ease of operation. Unlike Coomassie Blue stain, the FluoroStain Protein Fluorescent Staining Dye binds to protein with high specificity, making destaining process an option rather than a requirement. With further reduction of background signals via destaining process, the FluoroStain™ is capable of achieving detection level parallel to silver staining without specialized imaging equipment, making it one of the most sensitive dyes available. In addition to its remarkable sensitivity, the FluoroStain™ Protein Fluorescent Staining Dye (Red, 1000×) brings a more reliable and safer user experience, since the stained gel can be visualized with blue-light illumination, avoiding the risk of skin/ eye damage caused by UV light. For best result, we suggest using B-BOX™ Blue Light LED epi-illuminator to visualize and analyze the gel stained with FluoroStain Protein Fluorescent Staining Dye (Red, 1000×). The FluoroStain™ Protein Fluorescent Staining Dye is compatible to the analysis of mass spectra, i.e. LC-MS/MS, MALDI-TOF, etc.
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio
Privacy Policy | Terms of Use | Site Map