High Sensitivity Specificity DNA Isothermal PCR Kit NFO 48 Tests / Kit
Facebook
X
Pinterest
Email
Detail
Product Description
High Sensitivity & Specificity DNA Isothermal Amplification Kit NFO 48 Tests/Kit by Amp-future
Product Detail
Kit Storage and term of Validity
Storage term: stored at ≤-20℃,keep away from light, avoid heavy weight and repeated freezing and thawing.
Term of Validity: 14 months
Isothermal nucleic acid Principle Summary
The kit is based on room and constant temperature nucleic acid rapid amplification technology, its principle is that at room and constant temperature, the recombinase and primer form a protein/single-stranded nucleotide complex Rec/ssDNA, and invade the double-stranded DNA template with the help of auxiliary proteins and single-stranded binding protein SSB; then form a D-loop region at the invasion point and start to scan the DNA duplex, after finding the target region complementary to the primer and disintegration of the complex Rec/ssDNA, the polymerase also binds to the 3′ end of the primer to start the chain extension. The kit relies on the role of NFO enzyme and adds the designed specific molecular probes according to the template, and get the result by colloidal gold technology (sandwich method).
Isothermal nucleic acid Product Features
1/ High sensitivity and specificity, short reaction time.
2/ The reagent form is freeze-dried, stable and easy to operate.
3/ The reaction can be operated by metal bath and water bath pot without purchasing expensive PCR apparatus.
Technical Parameters:
Parameters
Details
Product Name
DNA Isothermal Amplification Kit NFO
Manufacturer
Amp-future
Storage Temperature
-20°C
Kit Components
Enzymes, Buffers ,Reagents
Packaging
48 Tests/box
Detection Limit
500-1000copies/µL
Shipping
ICE
Test Time
5-20mins
Isothermal nucleic acid Applications
Suitable for DNA isothermal rapid amplification kit(NFO type)
Primer: Require pair of nucleotide primers with the length of 25-35 bp.
DNA basic kit reaction temperature is 39 to 42℃ and time is 5-20 minutes.
Notes
1/ Please avoid nucleic acid contamination and set blank control during reaction due to the high sensitivity of the kit.
2/ Please take out the required quantity of MIRA reaction units for the experiment, and put the rest under storage conditions when performing the experiment.
Other Products
022143P1 Macconkey Agar
Product Info
Document
Product Info
Introduction
Usages: For isolating lactose-fermenting Gram-negative enteric bacilli.
Principle: Peptones are sources of nitrogen and other nutrients. Lactose is a fermentable carbohydrate. When lactose is fermented, alocal pH drop around the colony causes a color change in the pH indicator (neutral red) and bile precipitation. Bile salts,bile salts no. 3, oxgall and crystal violet are selective agents that inhibit growth of gram-positive organisms. Agar is the solidifying agent.
Formulation(per liter):
Pancreatic Digest of Gelatin
17.0 g
Peptones (meat and casein)
3.0 g
Lactose Monohydrate
10.0 g
Sodium Chloride
5.0 g
Bile Salts
1.5 g
Agar
13.5 g
Neutral Red
30.0 mg
Crystal Violet
1 mg
Final pH
7.1±0.2
How to use: 1.Suspend 50 g in 1 L of distilled or deionized water. Heat to boiling to dissolve completely. Autoclave at 121°C for 15 minutes.
2.Transfer 1 mL of Soybean–Casein Digest Broth to 100 mL of MacConkey Broth, and incubate at 42 to 44 for 24 to 48 hours. Subculture on a plate of MacConkey Agar at 30 to 35 deg.C for 18 to 72 hours.
Quality control:
Item
The name and number of strain
PR/G
Reaction
Growth rate
E.Coli ATCC8739
PR≥0.7
Rose-red
Characteristic difference
Proteus mirabilis CMCC(b)49005
PR≥0.7
Colorless, no swarming
Selective
Staphylococcus aureus ATCC6538
G≤1
-
Storage: Keep container tightly closed, store in a cool, dry place, away from bright light. Storage period of three years.
Extract total RNA (including microRNA) from FFPE samples
No phenol extraction step
Includes DNase for optional on-column DNA removal
Isolated RNA is of the highest quality and integrity
Isolate a diversity of RNA species
Purified RNA is suitable for a variety of downstream applications, including Small RNA Sequencing. Find out more information on Norgen’s NGS services
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
Norgen’s FFPE RNA Purification Kits provide a rapid method for the isolation and purification of total RNA (including microRNA) from formalin-fixed paraffin-embedded (FFPE) tissue samples in as little as 1 hour. Using formalin to fix tissues leads to crosslinking of the RNA and proteins, and the process of embedding the tissue samples can also lead to fragmentation of the RNA over time. Norgen’s FFPE RNA Purification Kits provide conditions that allow for the partial reversing of the formalin modifications, resulting in a high quality and yield of RNA. These kits are able to purify all sizes of RNA, from large mRNA and ribosomal RNA down to microRNA (miRNA) and small interfering RNA (siRNA), depending on the age of the FFPE tissue as fragmentation of the RNA is known to occur over time. The RNA is preferentially purified from other cellular components without the use of phenol or chloroform.
FFPE RNA Purification Kit (Spin Column)
Maximum loading volume of 650 μL per column, and a maximum binding capacity of 50 μg per column.
Purification is based on 96-well column chromatography using Norgen’s proprietary resin as the separation matrix. Purification can be performed using either a vacuum manifold or centrifugation. Maximum loading volume of 400 μL per well, and a maximum binding capacity of 50 μg per well.
5 slices of < 20 µm thick paraffin slices 25 mg of unsectioned block
Average Yield
Variable due to age of paraffin blocks ~2-3 µg of Total RNA per 1 mg of fresh FFPE hamster kidney
* Time required for purification varies by length of Proteinase K incubation and formalin crosslink-reversal
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. The DNAse I and Proteinase K should be stored at -20°C upon arrival. This kit is stable for 1 year from the date of shipment.
1. User-Friendly Design: The chamber lid and tabletop are covered with heat-insulating resin materials, providing both protection against burns and an aesthetically pleasing appearance. The upward-opening flip-top door saves space, while the rounded corners prevent injury. The specially designed steam discharge and collection system minimizes steam burn risks and enhances operational convenience.
2. Interlock Mechanism and Safety Protection: The safety interlock system is designed to be more sensitive and secure. The chamber lid cannot be opened if there is pressure or steam inside the chamber. The lid can only be opened when the pressure gauge reads “0” MPa. The sterilizer will not start heating if the chamber lid is not properly locked. These features enhance the overall safety of the machine.
3. Over-temperature and Heating Protection: The system continuously monitors the temperature inside the sterilization chamber. If the temperature becomes too high or heating is abnormal, power will be automatically cut off to prevent overheating.
4. Automatic Fault Detection System: The machine performs an automatic self-check when powered on. If a fault occurs during operation, an audible alarm will sound, and a fault code will be displayed.
5. Lid Closure Check System: The system automatically detects whether the chamber lid is securely locked. If the lid is not properly locked, the sterilizer will not start.
6. Leakage, Over-current, and Short-Circuit Protection: If there is leakage in the heating elements or other components, or if over-current or short-circuit conditions occur, the system will automatically cut off power to prevent user injury.
7. Water Shortage and Independent Dry-Burning Protection: Equipped with a low water level sensor and independent dry-burning protection device, the system can monitor the water level in the chamber in real-time to prevent dry burning and avoid false readings. If the low water level sensor fails, the overheat and dry-burning protection system will automatically activate, cut off power to the heating ring, and sound an alarm to ensure safety.
8. Dual Pressure Protection: The system includes both a mechanical safety valve and an electronic over-pressure protection system. If pressure becomes abnormal, the system will relieve pressure and cut off power while sounding an alarm.
9. Back end Safety Testing: The system can be periodically tested for safety and protective measures.
10. Over-pressure Testing: Regular testing ensures that the instrument’s over-pressure protection system can automatically cut off power or that the safety valve can open to relieve pressure.
11. Performance Testing: The instrument’s safety performance has been tested by national authorized inspection agencies, and a test report is available.
Technical Parameters
Model
HB65A Standard TypeHB65B Auto Water Replenishment TypeHB65C Auto Drying Type
HB90AStandard TypeHB90BAuto Water Replenishment TypeHB90CAuto Drying Type
HB110AStandard TypeHB110BAuto Water Replenishment TypeHB110CAuto Drying Type
Capacity
65L
90L
110L
Dimensions (L × W × H) mm
664×660×994.5
664×660×994.5
664×660×1200
Sterilization Chamber Dimensions (Diameter × Height) mm
Timer Pre-set Range: Set operating time (year, month, day, hour, minute), check current time (year, month, day, hour, minute), total sterilization cycles, fault occurrence time, and code.
Pressure Gauge Display Range
0~0.6Mpa
Pressure
Chamber Design Pressure: 0.35 MPa; Each product comes with a quality certificate and a certificate issued by the special equipment manufacturing supervision and inspection department.
Pressure Safety Protection
Dual independent pipeline measurement and control, mechanical and electronic dual pressure protection
Fully automatic internal exhaust (see instructions for exhaust temperature settings), built-in large-capacity steam condensate collection bottle and water tank
Door lock interlocking device; Cover closing check; Dry burn protection; Water level sensor monitoring; Electronic over pressure protection; Mechanical safety valve; Over temperature and heating protection; Over current and short circuit protection; Leakage protection; Cooling lock; Burn injury safety protection; Automatic fault detection system
Printer, cooling fan, item temperature sensor, USB output
Stainless Steel Baskets
(φ360×230)1pcs(φ360×200)1pcs
(φ360×200)1pcs(φ360×400)1pcs
(φ360×200)2pcs(φ360×400)1pcs
Note: The upper limits for cooling lock door temperature and exhaust temperature are related to the boiling point.
Other Optional Accessories
1. Dot Matrix Printer: Capable of printing temperature, time, F0 value, and pressure data. USB data export and curve plotting.
2. Stainless Steel Basket with Base.
3. Pressure Sensor
4. Stainless Steel Bucket
5. Item Thermometer
6. 3Q Validation Adapter
Document
Features and functions:
1. Large-diameter sterilization chamber:The 40 cm large-diameter sterilization chamber provides an exceptionally spacious environment to meet a wide range of sterilization needs.
2. Sterilization temperature:105-138℃.
3. Exhaust control :After sterilization is complete, the exhaust valve can automatically open to release the exhaust at a pre-set temperature.
4. Verification interface: Provides temperature and pressure inspection ports for easy calibration.
5. Saturated steam monitoring:The system automatically monitors the expulsion of cold air to ensure a pure steam sterilization environment, guaranteeing optimal sterilization effectiveness.
6. Pressure performance:The chamber is designed to withstand a pressure of up to 0.35 MPa, and each unit is tested with a water pressure of up to 0.44 MPa. Advanced pressure protection ensures the safety load of the equipment.
7. Intelligent control system:The microcomputer chip-based intelligent control system monitors the temperature and pressure inside the sterilization chamber in real-time. The chamber lid can only be opened under safe temperature and pressure conditions. The system also provides fully automatic control of the sterilization process and allows for convenient maintenance, inspection, calibration, recording, and future upgrades.
8. Six preset programs:Includes six fixed programs for liquid sterilization and holding, solid sterilization and drying, agar melting and holding, and waste sterilization.
9. Memory storage system:Users can set their own parameters, create multiple programs, and access them at any time. The system allows for operation permissions to be set at three levels—user, administrator, and engineer—to facilitate effective use and management of the sterilizer.
10. Door-opening temperature: Each program can be set with a specific cooling lock door-opening temperature based on the thermal inertia of the sterilized items. This prevents users from opening the door when the items (especially liquid sterilized items) are still in an unsafe condition, thus avoiding burns.
11. Drying function: Thorough drying that meets CE standards, with a cooling lock mechanism.
12. One-touch inquiry function: Allows checking of current time, total number of sterilization cycles, fault occurrence time, and codes.
13. Scheduled start function: Allows you to set a start time so that the sterilizer automatically starts at the scheduled time.