Detection kits for HIV
Available in TaqMan format for analysis
Human Immunodeficiency Virus (HIV) is a retrovirus which destroys essential cells in the human immune system, such as CD4+ lymphocytes (a type of T cell), macrophages and dendritic cells. Infection with HIV therefore leads to an impaired immune system and increased susceptibility to opportunistic cancers and infections. Due to the mutating nature of HIV and damage to the T cells, the immune system is unable to fight off infections and disease. Without treatment, HIV can progress to Acquired Immunodeficiency Syndrome (AIDS). The rate of HIV progression to AIDS depends on a number of different factors including viral, host and environmental factors. However, with adherence to antiretroviral therapy (ART), many individuals with HIV will never progress to AIDS, having near normal life expectancy. Transmission of HIV is through direct contact with infected bodily fluids, either sexually; by the sharing of blood-contaminated needles or instruments; maternally through childbirth or breastfeeding; or via blood transfusion/organ transplant.
HIV TaqMan RT-PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
HIV TaqMan RT-PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s RT-PCR Master Mix (#28113) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Storage Conditions and Product Stability All kit components can be stored for 1 year after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component
Cat. TM33750 (100 preps)
Cat. TM33710 (100 preps)
MDx TaqMan 2X PCR Master Mix
2 x 700 μL
–
HIV Primer & Probe Mix
280 μL
280 μL
HIV Positive Control
150 μL
150 μL
Nuclease-Free Water (Negative Control)
1.25 mL
1.25 mL
Product Insert
1
1
Other Products
EXTRAClean Plasma/Serum RNA Purification Kit
Product Info
Document
Product Info
Overview
Versatile plasma/serum input ranges
No phenol extractions
Fast and easy processing of samples for the purification and the isolation of RNA.
These kits provide a fast, reliable and convenient method to purify and concentrate high quality, high purity and inhibitor-free cell-free circulating and exosomal RNA using a convenient spin column method. These kits can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate. Plasma samples prepared from blood collected on heparin should not be used, as heparin can significantly interfere with many downstream applications such as RT-PCR. The purified plasma/serum RNA is fully compatible with all downstream applications including PCR, qPCR, methylation-sensitive reverse transcription qPCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, expression array assays, and NGS. The EXTRAClean columns undergo stringent processing and rigorous quality control measures to minimize contamination traces, ensuring optimal results for sensitive applications such as NGS.
Background
Cell-free circulating RNA, including exosomal RNA in plasma or serum, has the potential to provide biomarkers for certain cancers and disease states, and includes tumor-specific extracellular RNA in the blood. Exosomes are 40 – 100 nm membrane vesicles, which are secreted by most cell types. Exosomes can be found in saliva, blood, urine, amniotic fluid and malignant ascitic fluids, among other biological fluids. Evidence has been accumulating recently that these vesicles act as cellular messengers, conveying information to distant cells and tissues within the body. The exosomes contain cell-specific proteins, lipids and RNAs, which are transported to other cells, where they can alter function and/or physiology. These exosomes may play a functional role in mediating adaptive immune responses to infectious agents and tumours, tissue repair, neural communication and transfer of pathogenic proteins. Recent work has demonstrated the presence of distinct subsets of microRNAs within exosomes which depend upon the tumour cell type from which they are secreted. For this reason, exosomal RNAs may serve as biomarkers for various diseases including cancer. As the RNA molecules encapsulated within exosomes are protected from degradation by RNAses, they can be efficiently recovered from biological fluids, such as plasma or serum.
EXTRAClean Plasma/Serum RNA Purification Mini Kit
This kit can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate, from volumes ranging from 50 μL to 200 μL. The purified plasma/serum RNA is eluted in a flexible final volume of 10 μL to 25 μL.
EXTRAClean Plasma/Serum RNA Purification Midi Kit
This utilizes a two-column method, and can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate, from volumes ranging from 250 μL to 1.5 mL. The first column will handle the large volume input of bodily fluids that is followed by a concentration on a mini column for a final elution of 50 μL to 100 μL.
EXTRAClean Plasma/Serum RNA Purification Maxi Kit
This kit can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate, from volumes ranging from 2 mL to 5 mL. The first column will handle the large volume input of bodily fluids that is followed by a concentration on a mini column for a final elution of 50 μL to 100 μL.
All sizes, including miRNA and small RNA (<200 nt)
Average Yields¥
Variable depending on specimen
† This kit is suitable for the isolation of RNA from fresh or frozen serum or plasma prepared from blood collected on either EDTA or Citrate. Plasma samples prepared from blood collected on heparin should not be used as heparin can significantly interfere with many downstream applications such as RT-PCR
¥ Please check page 5 for Average Plasma/Serum Yields and Common RNA Quantification Methods
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.
Chlamydia trachomatis, the causative agent of Chlamydia, is a Gram negative bacteria. Transmission of the bacteria occurs via contact with infected bodily fluids which then infect mucosal membranes. It can be transmitted from mother to child during pregnancy and infect the eyes causing conjunctivitis. The genital infection causes urethritis, epididymitis and prostatitis in males and Pelvic Inflammatory Disease (PID) in females with an increased risk of contracting HIV. The infection can be treated with a course of antibiotics. Sexually transmitted infections in females are most often asymptomatic, but can be noticeable in chronic pain of the pelvic region, vaginal bleeding and painful urination. Infection of the ovaries, fallopian tubes or uterus causes Pelvic Inflammatory Disease (PID) which can lead to difficulties in conceiving, increased risk of ectopic pregnancy or infertility. Infections in males are more likely to be symptomatic, causing painful urination, discharge from the penis and swollen testicles and may eventually cause infertility if left untreated.
Chlamydia TaqMan PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
Chlamydia TaqMan PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Storage Conditions and Product Stability All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component
Cat. TM30950 (100 preps)
Cat. TM30910 (100 preps)
MDx TaqMan 2X PCR Master Mix
2 x 700 μL
–
Chlamydia Primer & Probe Mix
280 μL
280 μL
Chlamydia Positive Control
150 μL
150 μL
Nuclease-Free Water (Negative Control)
1.25 mL
1.25 mL
Product Insert
1
1
Overview
Detection kits for Chlamydia
Available in TaqMan format for analysis
Chlamydia trachomatis, the causative agent of Chlamydia, is a Gram negative bacteria. Transmission of the bacteria occurs via contact with infected bodily fluids which then infect mucosal membranes. It can be transmitted from mother to child during pregnancy and infect the eyes causing conjunctivitis. The genital infection causes urethritis, epididymitis and prostatitis in males and Pelvic Inflammatory Disease (PID) in females with an increased risk of contracting HIV. The infection can be treated with a course of antibiotics. Sexually transmitted infections in females are most often asymptomatic, but can be noticeable in chronic pain of the pelvic region, vaginal bleeding and painful urination. Infection of the ovaries, fallopian tubes or uterus causes Pelvic Inflammatory Disease (PID) which can lead to difficulties in conceiving, increased risk of ectopic pregnancy or infertility. Infections in males are more likely to be symptomatic, causing painful urination, discharge from the penis and swollen testicles and may eventually cause infertility if left untreated.
Chlamydia TaqMan PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
Chlamydia TaqMan PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Storage Conditions and Product Stability All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
NGS FFPE DNA Library Prep Kit (illumina and MGI Platforms)
Product Info
Document
Product Info
The NGS FFPE DNA Library Prep Kit (illumina and MGI Platforms) was developed for the construction of high quality FFPE DNA libraries using 10 ng to 400 ng of input DNA isolated from formalin-fixed, paraffin-embedded (FFPE) samples. The DNA damage caused by fixation makes it difficult to construct high quality libraries. Our kit has been optimized to repair damaged DNA in the reactions. Multiplexing of the NGS FFPE DNA Library is possible.
NGS FFPE DNA Library Prep Kit Workflow
FFPE samples are a great resource for biomedical research. However, the methods for fixation and condition of storage significantly damage the DNA in the samples. Thus, the extraction of high quality DNA from FFPE samples is often a challenge. Low yield and low quality of FFPE DNA usually are common because of the limited tissue material and the DNA degradation.
As a result, it is usually difficult to construct high quality NGS libraries from low amount and low quality of FFPE DNA. In order to address this issue, we have developed the NGS FFPE DNA Library Prep Kit to make high quality libraries from the low input of FFPE DNA samples.
Three index types are available for the NGS FFPE DNA Library Prep Kit of the illumina platform:
Non-index (Cat.# 30035): Libraries do not have index.
Index (Cat.# 30037): Each of our index primers contains a unique barcode DNA (6 bases long) that can be used to identify individual library. Multiplexing of libraries is up to 48 samples. Index information can be downloaded here.
Unique dual index (Cat.# 30039): FFPE DNA library multiplexing is possible with 96 samples based on the unique dual indexing system. Our unique Four–Base Difference Index System allows us to make indexes that have at least 4 bases different from each other in the 8-base index sequence. Our unique dual indexing primers can effectively remove NGS errors including index hopping, de-multiplexing errors, index cross-contamination, mis-assignments etc. The unique dual index primer set includes 96 pre-mixed unique pairs of i5 and i7 index primers. Index information can be downloaded here.
Indexes are available for the MGI platform kits (Cat.# 34037).
Kit advantages:
Fast and simple protocol
Making libraries in just 1.5 hours
10 minutes of hands-on time
Easy procedure
Ready-to-use master mix to reduce the tedious mixing
Less reaction components to simplify the reaction setup
Less magnetic beads needed for the purification steps: saving more than 50% of the expensive beads
Low input FFPE DNA: From 10 ng to 400 ng
Comparison of library conversion efficiency under the same condition. Input DNA amount is 25 ng.
Comparison of library yield under the same condition. Input DNA amount is 25 ng.
Document
The NGS FFPE DNA Library Prep Kit (illumina and MGI Platforms) was developed for the construction of high quality FFPE DNA libraries using 10 ng to 400 ng of input DNA isolated from formalin-fixed, paraffin-embedded (FFPE) samples. The DNA damage caused by fixation makes it difficult to construct high quality libraries. Our kit has been optimized to repair damaged DNA in the reactions. Multiplexing of the NGS FFPE DNA Library is possible.