Human Papillomavirus (HPV) (High Risk) TaqMan PCR Detection Kits

Facebook
X
Pinterest
Email

Detail

Overview

  • Detection kits for the HPV (High Risk)
  • Available in TaqMan format for analysis

More than 70 types of human papillomavirus (HPV) have been identified, and are generally classified as high-risk or low-risk depending on their relationship or lack of relationship with cancer and high-grade cervical intraepithelial neoplasia (CIN 2-3). HPV viruses are predominantly sexually transmitted and high-risk HPV types are a major risk factor for development of cervical cancer. Low-risk HPV types 6 and 11 have been associated with the presence of genital warts. There are many other low-risk HPV types that are not associated with genital warts or cervical cancer. Until now, HPV cannot be cultured in vitro, and immunological tests are inadequate to determine the presence of HPV cervical infection. On the other hand, biopsies can be analyzed by nucleic acid hybridization to directly detect the presence of HPV DNA. HPV 16 and HPV 18 have been considered as high-risk cancer associated HPV types.

HPV (High Risk) TaqMan PCR Kit, 100 reactions

  • Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
  • Specific Primer and Probe mix for the pathogen/virus/viroid of interest
  • Primer and Probe mix
  • Positive and negative control to confirm the integrity of the kit reagents

HPV (High Risk) TaqMan PCR Probe/Primer Set and Controls, 100 reactions

  • Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
  • Nuclease-free water
  • Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix

For research use only and NOT intended for in vitro diagnostics.

Details

Supporting Data

Figure 1 / 5

Previous

Figure 1. Example of TaqMan PCR Positive result
Figure 1. Example of TaqMan PCR Positive result
Figure 2. Example of TaqMan PCR Positive (Cy5) result
Figure 3. Example of TaqMan PCR Positive (FAM) result
Figure 4. Example of TaqMan PCR Negative result
Figure 5. Example of TaqMan PCR inhibition result

Next

Click for expanded view

Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.

All kit components should be stored at -20°C upon arrival.

ComponentCat. TM32250 (100 preps)Cat. TM32210 (100 preps)
MDx TaqMan 2X PCR Master Mix2 x 700 μL
HPV (High Risk) Primer & Probe Mix280 μL280 μL
HPV (High Risk) Positive Control150 μL150 μL
Nuclease-Free Water (Negative Control)1.25 mL1.25 mL
Product Insert11