The HybriDetect is a simple and quick tool to develop your own rapid test. Various molecules can be detected: Proteins, Antibodies, Genetic amplicons
Detail
Name of Product
HybriDetect – Universal Lateral Flow Assay Kit
Catalog Number
MGHD 1
Short Info
The HybriDetect is a simple and quick tool to develop your own rapid test. Various molecules can be detected: Proteins, Antibodies, Genetic amplicons
Please note, that you may have to pay country-specific taxes and duties.
Method/Platform
Lateral flow, sandwich or competetive
Range/Assay Sensivity
5 pg DNA, eqivalent to agarose gel electrophoresis
Test Principle
HybriDetect is a ready-to-use, universal test strip (dipstick) based on lateral flow technology using gold particles. The dipstick can be used to develop qualitative or quantitative rapid test systems for a wide range of analytes such as antibodies, gene amplification products or proteins . The results can be interpreted qualitative or quantitative.
Other Products
Blood card/ gel cards centrifuge TXK4
Product Info
Document
Product Info
TXK4 Blood card centrifuge, ID card Centrifuge, Gel card centrifuge
Application:
TXK4 blood group serological tests multipurpose centrifuge widely used in the test of blood group serology, blood type, Microcolumn agglutination, immunodetection and etc.
Features:
1. Brushless motor to make sure free maintenance,no powder polution, micro computer control and digital display the time, speed and RCF to let operation easily.
2. Special centrifugation technical to different reagent according to the requirement.
3. Regular centrifugation program, customers can press the button to choose the required one.
4. Electrical lid lock, over speed and imbalance protection.
Technical Parameters:
Max speed
4000rpm
Max RCF
2250xg
Max volume
24 cards
Noise
≤45dBA
Timer
0~99min
Net weight
23KG
Dimension(HxDxW)
483×320×265mm
Power supply
AC 220 50HZ 2A
Speed accuracy
±10rpm
Package
carton box
Matched Rotors for TXK4:
Order No.
Rotor Type
Max Speed (rpm)
Max Volume (ml)
Max RCF(g)
NO33183
Swing Rotor
3000
24 cards
1080
4000
24 cards
2120
NO31605
Fixed Rotor
4000
30×7/5ml
2250
NO31601
Fixed Rotor
4000
12×10ml
2150
Document
TXK4 blood group serological tests multipurpose centrifuge widely used in the test of blood group serology, blood type, Microcolumn agglutination, immunodetection and etc.
The BK virus is a member of the polyomavirus family. It has been suggested that this virus may be transmitted through respiratory fluids or urine, since infected individuals periodically excrete virus in the urine. BK viral infections are typically asymptomatic in healthy individuals, however very mild symptoms may appear including mild respiratory infections and fever. Infections with BK virus in immunocompromised or immunosupressed patients are much more severe and may involve renal dysfunction. In fact, in kidney transplant patients the immunosupressive drugs required for the transplant may allow the virus to replicate within the graft, resulting in a disease called BK virus nephropathy (BKVN). The JC virus is a type of human polyomavirus and is very common in the general population, infecting 70 to 90% of humans. Most people acquire JCV in childhood or adolescence. Typically the infection is subclinical and no of consequence in individuals with healthy immune systems. The initial site of infection may be the tonsils or the gastrointestinal tract, and the virus then remains latent in the gastrointestinal tract. JCV can also infect the tubular epithelial cells in the kidneys, where it continues to reproduce, shedding virus particles in the urine. Also, JCV can cross the blood-brain barrier into the central nervous system. JCV is known to cause the usually fatal progressive multifocal leukoencephalopathy (PML) by destroying oligodendrocytes in the brain in immunodeficient or immunosuppressed individuals. The JC and BK viruses are very similar, with their genomes sharing 75% homology. It is however important to differentiate between the viruses due to the differences in pathology and especially the invariably fatal outcome of PML which is only caused by the JC virus.
BKV/JCV TaqMan PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
BKV/JCV TaqMan PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Storage Conditions and Product Stability All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
An adapter for Cerillo’s Alto plate reader. This adapter allows the Alto plate reader to fit perfectly on the deck of the Opentrons Flex or OT-2 to allow for pipetting directly into the reader.
Document
An adapter for Cerillo’s Alto plate reader. This adapter allows the Alto plate reader to fit perfectly on the deck of the Opentrons Flex or OT-2 to allow for pipetting directly into the reader.