One cDNA Synthesis, Multiple microRNAs and microRNA-targets analyzed
Time Savings
Cost Efficient
High Sensitivity and Yield
Robust Enzyme
Available in 12 or 50 reaction size
Norgen’s microScript microRNA cDNA Synthesis Kit is an all-in-one, ready-to-use product for the reverse transcription of microRNA from either Total RNA preparations or enriched microRNA preparations. The kit contains the 2x Reaction Mix and the microScript microRNA Enzyme Mix. The kit utilizes Norgen’s microScript Reverse Transcriptase, a mutant version of Moloney Murine Leukemia Virus (M-MuLV) Reverse Transcriptase. It has reduced RNase H activity and increased thermal stability.
The workflow of Norgen’s microScript microRNA cDNA Synthesis Kit involves a simple, single-tube set-up by the mixing of 2x Reaction Mix, Enzyme Mix and the RNA template. The reaction can then be carried out in a thermocycler. A poly (A) tail is first added to the RNA template, followed by cDNA synthesis using an adapter primer. In addition to the ease-of-use, the single-tube set-up provides superb consistency and sensitivity. The cDNA could be used in a PCR or qPCR amplification using a Universal PCR Reverse Primer and the forward primer that contains the sequence of the microRNA of interest. A single cDNA preparation could be used for PCR amplification of a number of different microRNAs. In addition, the cDNA preparation could be used for PCR or qPCR detection (using gene-specific forward and reverse primers) of mRNA or large RNA if total RNA preparation was the starting template. This could allow for parallel evaluation of expression level of microRNAs and microRNA-targets.
Storage Conditions and Product Stability This kit is stable for 1 year after the date of shipment .
Component
Cat. 54415 (12 rxns)
Cat. 54410 (50 rxns)
microScript microRNA Enzyme Mix
12 μL
50 μL
2x Reaction Mix
120 μL
500 μL
Universal PCR Reverse Primer
60 μL
250 μL
Nuclease-Free Water
1.25 mL
2 x 1.25 mL
Product Insert
1
1
Other Products
Propargyl-PEG4-bromide
Product Info
Document
Product Info
Propargyl-PEG4-bromide is a crosslinker that can be used in copper catalyzed azide-alkyne Click Chemistry to form a stable triazole linkage with azides. The bromide (Br) acts as a good leaving group for nucleophilic substitution reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Document
Propargyl-PEG4-bromide is a crosslinker that can be used in copper catalyzed azide-alkyne Click Chemistry to form a stable triazole linkage with azides. The bromide (Br) acts as a good leaving group for nucleophilic substitution reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Isolate and extract high quality & quantity miRNA in 30 minutes
Two column kit- eliminate large RNA on the first column and capture microRNA on a second column
Elute microRNA in 25 µL ready for miRNA profiling
Process a wide range of samples- cell, tissue, bacteria, bodily fluids, etc.
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
This kit provides a rapid method for the isolation and purification of small RNA molecules (< 200 nt) from cultured animal cells, small tissue samples, bacterial cells, plants, and blood.
Two columns are provided with this kit. The first column captures large RNA, while the small RNA are captured on a second column and are eluted concentrated in 25 µL of nuclease-free water.
The small RNA can be used in various downstream applications relating to miRNA profiling, gene regulation, and functional analysis. The eluted RNA is ready for RT-qPCR, microarrays, and NGS applications.
Background
These small RNAs include regulatory RNA molecules such as microRNA (miRNA) and short interfering RNA (siRNA), as well as tRNA and 5S rRNA. Small RNA molecules are often studied due to their ability to regulate gene expression. miRNAs and siRNAs are typically 20-25 nucleotides long and regulate gene expression by binding to mRNA molecules and affecting their stability or translation.
Maximum Amount of Starting Material: Animal Cells Animal Tissues Bacteria Plant Tissues Blood
3 x 106 cells 5-25 mg 1 x 109 cells 50 mg 100 μL
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 1 year after the date of shipment.
All-in-one solution for inclusion body protein isolation and purification
Fast and convenient spin column protocol
Complete kit with Cell Lysis Reagent, Inclusion Body Solubilization Reagent, buffers and spin columns to purify proteins
Purification is based on spin column chromatography that uses Norgen’s resin separation matrix
These kits provide everything required to isolate and purify inclusion body proteins from induced bacterial cultures. First a proprietary Cell Lysis Reagent is used to selectively lyse the cells and release inclusion bodies in their solid form. Next, inclusion bodies are dissolved and their contents released using the provided IB Solubilization Reagent. Inclusion body proteins are then further purified using spin columns for rapid and convenient buffer exchange and desalting. This kit provides a convenient way to screen recombinants prior to scaling up.
ProteoSpin™ Inclusion Body Protein Isolation Micro Kit
The process is efficient and streamlined and can process up to 12 samples in only 60 minutes. Each spin column is able to recover up to 50 µg of acidic or basic proteins. Purified recombinant proteins are then ready for SDS-PAGE, 2D gels, Western blots, Mass Spectrometry analysis, and other applications.
ProteoSpin™ Inclusion Body Protein Isolation Maxi Kit
The procedure is efficient and streamlined and can process up to 4 samples in approximately 2 hours. Each spin column is able to recover up to 12 mg of acidic or basic proteins from 100 mL of induced bacterial culture. Purified recombinant proteins are then ready for SDS-PAGE, 2D gels, Western blots, Mass Spectrometry analysis, and other applications.
About Inclusion Bodies
Bacteria are widely used for the expression of different proteins. However, 70-80% of the proteins expressed in bacteria by recombinant techniques are typically contained in insoluble inclusion bodies (i.e., protein aggregates). The protein of interest found in these subcellular structures is often inactive, due to incorrect folding. The production rate of recombinant proteins stored in inclusion bodies is invariably higher than those synthesized as soluble proteins. The reason behind this is thought to be the resistance of insoluble proteins to proteolysis by cellular enzymes. In addition, separation of insoluble recombinant proteins in inclusion bodies is considerably easier than that of soluble proteins. These factors have been the major influences favoring scale-up of high-value proteins using bacterial fermentation for example. Procedures for the purification of the expressed proteins from inclusion bodies are often labour-intensive, time-consuming and not cost-effective. This kit provides the essential reagents for cell disruption, inclusion body solubilization and purification using spin column chromatography – all optimized to work together thereby simplifying the process and saving a tremendous amount of time and cost.
Storage Conditions The Cell Lysis Reagent and IB Solubilization Reagent should be stored at 4°C upon receipt of this kit. This kit is stable for 2 years after the date of shipment. Once opened, the solutions should be stored at 4°C when not in use except for Binding Buffer C and Binding Buffer N. Some precipitation will occur with 4°C storage. This precipitation should be dissolved with slight heating to room temperature before using.
Component
Cat. 10300 (Micro – 25 preps)
Cat. 17700 (Maxi – 4 preps)
Wash Solution C
30 mL
130 mL
Wash Solution N
30 mL
130 mL
Binding BUffer A
4 mL
20 mL
Binding Buffer N
4 mL
20 mL
Elution Buffer C
8 mL
2 x 30 mL
Protein Neutralizer
4 mL
4 mL
Cell Lysis Reagent
15 mL
110 mL
IB Solubilization Reagent
2 mL
50 mL
Syringes, 1cc, slip tip
25
–
Needles (Bev, 20G x 1 inch)
25
–
Syringes, 10 mL, Luer-Lok™ Tip
–
4
Needles (18G x 1.5 inch)
–
4
Micro Spin Columns
25
–
Maxi Spin Columns (filled with SiC) inserted into 50 mL collection tubes