
Opentrons OT-2 8-Channel Electronic Pipettes automate liquid handling and pipetting for most daily wetlab applications. Best for medium- to high-throughput workflows.
Opentrons OT-2 8-Channel Electronic Pipettes automate liquid handling and pipetting for most daily wetlab applications. Best for medium- to high-throughput workflows.
Opentrons OT-2 8-Channel Electronic Pipettes automate liquid handling and pipetting for most daily wetlab applications. Best for medium- to high-throughput workflows.
Norgen’s Exosome Purification and RNA Isolation Kits constitute all-in-one systems for the purification of exosomes and the subsequent isolation of exosomal RNA from different urine sample volumes. The purification is based on spin column chromatography that employs Norgen’s proprietary resin. These kits are designed to isolate all sizes of RNA, including microRNA, irrespective of size or GC content, without bias. These kits provide a clear advantage over other available kits in that they do not require any special instrumentation, protein precipitation reagents, extension tubes, phenol/chloroform or protease treatments. Moreover, the kit allows the user to elute into a flexible elution volume ranging from 50 µL to 100 µL. The purified RNA is free from any protein-bound circulating RNA and of the highest integrity. The purified RNA can be used in a number of downstream applications including real time PCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, and expression array assays.
Urine Exosome Purification and RNA Isolation Mini Kit
For sample volumes ranging from 250 µL to 1 mL.
Urine Exosome Purification and RNA Isolation Midi Kit
For sample volumes ranging from 2 mL to 10 mL.
Urine Exosome Purification and RNA Isolation Maxi Kit
For sample volumes ranging from 11 mL to 30 mL.
Figure 1 / 5
Click for expanded view
Kit Specifications | |
Minimum Urine Input | 250 μL |
Maximum Urine Input | 1 mL |
Size of Exosomes Purified | 40 nm – 150 nm |
Size of RNA Purified | All sizes, including miRNA and small RNA (< 200 nt) |
Elution Volume | 50-100 μL |
Time to Complete 10 Purifications | 35 – 40 minutes |
Average Yields* | Variable depending on specimen |
*Please check page 4 of the product insert for the average yields and the common RNA quantification methods.
Storage Conditions and Product Stability
All buffers should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.
Important Note
Urine samples stored at -70°C, -20°C or at 4°C will develop some precipitation due to the aggregation of some of the highly abundant proteins in urine. Eliminating these precipitates using centrifugation or filtration may cause the loss of exosomes. Furthermore, these precipitates may affect the quality of the purified nucleic acid. We recommend the use of Norgen’s Urine Preservative when collecting urine samples, which is designed for the preservation of nucleic acids and proteins in fresh urine samples at ambient temperatures. The components of the Urine Preservative allow samples to be stored for over 2 years at room temperature with no detected degradation of urine DNA, RNA or proteins. Norgen’s Urine Preservative is available as a liquid format in Norgen’s Urine Preservative Single Dose Ampules, as well as in a dried format in Norgen’s Urine Collection and Preservation Tubes.
Component | Cat. 58400 (50 preps) | Cat. 58700 (25 preps) | Cat. 58800 (15 preps) |
---|---|---|---|
Slurry E | 12.5 mL | 12.5 mL | 12.5 mL |
ExoC Buffer | 8 mL | 30 mL | 50 mL |
ExoR Buffer | 12 mL | 12 mL | 12 mL |
Lysis Buffer A | 20 mL | 20 mL | 20 mL |
Lysis Additive B | 2 mL | 2 mL | 2 mL |
Wash Solution A | 18 mL | 18 mL | 18 mL |
Elution Solution A | 6 mL | 6 mL | 6 mL |
Mini Filter Spin Columns | 50 | 25 | 15 |
Mini Spin Columns | 50 | 25 | 15 |
Collection Tubes | 50 | 25 | 15 |
Elution Tubes (1.7 mL) | 100 | 50 | 30 |
Product Insert | 1 | 1 | 1 |
This kit provides fast purification of high-quality RNA from cells, tissues, and yeast using silica-membrane spin columns with a binding capacity of 100μg RNA. There is no need for phenol/chloroform extractions and time-consuming steps such as CsCl gradient ultracentrifugation or isopropanol precipitation. RNA purified using the HiPure Total RNA Purification System can be used for applications such as RT-PCR, Northern blotting, poly A+ RNA (mRNA) purification, nuclease protection, and in vitro translation.
Specifications
Features | Specifications |
Main Functions | Isolation total RNA (not include miRNA) from 20mg tissue, 150mg plant, 5 x 106 cell using two columns (gDNA removed column) |
Applications | RT-PCR, qRT-PCR, Northern hybridization, second generation sequencing |
Purification method | Mini spin column |
Purification technology | Silica technology, DNA filtration technology |
Process method | Manual (centrifugation or vacuum) |
Sample type | Animal soft tissue, cultured cells, lymphocytes, simple plant tissue |
Sample amount | Cells:≤1 x 107 Animal tissue sample: 1-20 mgPlant tissue: 50-150 mg |
Yield | 2-100μg |
Elution volume | ≥50μl |
Time per run | ≤25 minutes(1-24 samples) |
Liquid carrying volume per column | 800µl |
Binding yield of column | 100µg |
The Kit isolates total RNA from up to 107 cells or 20 mg tissue. A short workflow enables RNA isolation with genomic DNA removal in less than 25 mins. Samples are first lysed and homogenized. The lysate is passed through a DNA Mini column, ethanol is added to the flow-through, and the sample is applied to a RNA column. RNA binds to the membrane and contaminants are washed away. High-quality RNA is eluted in as little as 30µl water using the Kit.
Advantages
Kit Contents
Contents | R411102 | D411103 |
Purification Times | 50 Preps | 250 Preps |
HiPure DNA Mini Columns | 50 | 250 |
HiPure RNA Mini Columns | 50 | 250 |
2ml Collection Tubes | 100 | 2 x 250 |
Buffer RLC | 50 ml | 200 ml |
Buffer RW1 | 50 ml | 200 ml |
Buffer RW2* | 12 ml | 2 x 50 ml |
RNase Free Water | 10 ml | 30 ml |
Storage and Stability
HiPureKit can be stored dry at room temperature (15-25°C) and are stable for at least18 months under these conditions. During shipment, crystals or precipitationmay form in the Buffer RLC. Dissolve by warming buffer to 37°C.
This kit provides fast purification of high-quality RNA from cells, tissues, and yeast using silica-membrane spin columns with a binding capacity of 100μg RNA. There is no need for phenol/chloroform extractions and time-consuming steps such as CsCl gradient ultracentrifugation or isopropanol precipitation. RNA purified using the HiPure Total RNA Purification System can be used for applications such as RT-PCR, Northern blotting, poly A+ RNA (mRNA) purification, nuclease protection, and in vitro translation.
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio
Privacy Policy | Terms of Use | Site Map