The HiPure Plasmid EF Mini Kit combine the power of HiPure technology with Magen’s innovative endotoxin removal technology to deliver high-quality plasmid DNA with low endotoxin levels foruse in eukaryotic transfection, and in vitro experiments. The HiPure plasmid endo-free system uses a specially formulated buffer that prevents endotoxin molecules from binding to the surface of the HiPure matrix. Endotoxin contamination lowers transfection efficiencies for endotoxin sensitive celllines. For gene therapy, endotoxin contamination should be of major concernsince endotoxins have the potential to cause fever, endotoxin shock syndrome, and interfere with in vitro transfection into immune cells.
Detail
Introduction
The HiPure Plasmid EF Mini Kit combine the power of HiPure technology with Magen’s innovative endotoxin removal technology to deliver high-quality plasmid DNA with low endotoxin levels foruse in eukaryotic transfection, and in vitro experiments. The HiPure plasmid endo-free system uses a specially formulated buffer that prevents endotoxin molecules from binding to the surface of the HiPure matrix. Endotoxin contamination lowers transfection efficiencies for endotoxin sensitive celllines. For gene therapy, endotoxin contamination should be of major concernsince endotoxins have the potential to cause fever, endotoxin shock syndrome, and interfere with in vitro transfection into immune cells.
Details
Specifications
Features
Specifications
Main Functions
Isolation up to 80µg endotoxin-free plasmid DNA from 5-15ml bacterial culture. Recommend for low copy vector, Thoroughly remove RNA
Applications
Cell transfection, animal injection, etc.
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Low copy plasmid vector
Sample amount
5-15ml LB
Yield
10-70μg
Elution volume
≥75μl
Time per run
≤40 minutes
Liquid carrying volume per column
800μl
Binding yield of column
70μg
Principle
The HiPure Plasmid procedure is based on alkaline lysis of bacterial cells followed by adsorption of DNA onto silica in the presence of high salt. The unique silica membrane used in the kit completely replaces glass or silica slurries for plasmid DNA minipreps. The procedure consists of 3 basic steps: Preparation and clearing of a bacterial lysate by alkaline method,then transfer the supernatant to column to bind DNA. After washing proteins and other impurities, nucleic acid was finally eluted with low-salt buffer (10mm Tris, pH9.0, 0.5mm EDTA).
Advantages
High purity – purified plasmid can be directly used in sequencing, enzyme digestion and PCR, etc.
Fast – silica gel column purification is much faster than ion exchange
High yield – up to 70μg plasmid can be binded in one column
Low endotoxin content – the obtained plasmid can be directly used in cell transfection and animal injection
Kit Contents
Contents
P115402
P115403
Purification Times
50 Preps
250 Preps
RNase A
5 mg
20 mg
Buffer P1
30 ml
140 ml
Buffer P2
30 ml
140 ml
Buffer LEN3
15 ml
70 ml
Buffer LN4
50 ml
250 ml
Buffer LN5
30 ml
140 ml
Buffer PW1
30 ml
140 ml
Buffer PW2
12 ml
50 ml
Elution Buffer
15 ml
30 ml
HiPure DNA Mini Columns III
50
250
2 ml Collection Tubes
50
250
Storage and Stability
The kit components can be stored dry at room temperature (15–25°C) and are stable for at least 18 months under these conditions. If any precipitates form in the buffers, warm at 37℃ to dissolve. After addition of RNase A,Buffer P1 is stable for 6 months when stored at 2–8°C.
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.
Refrigeration Series
● Dual compressors,Secop special compressors,air cooling (water cooling system is optional)
Silicone oil conducts heat,with uniform temperature and accuracy up to 0.1°C.Silicone oil has a wide temperature range,up to-100°C~+600°C.
● Shelf refrigeration system and cold trap refrigeration system are completely independent,without any switching,refrigeration temperature is lower and more stable.
Vacuum series
● Vacuum pump:German Pfeiffer anti-corrosion,anti-oil return function vacuum pump.(Vacuum pump can be selected according to user needs)
● Pumping rate:9m³/h~62m³/h,multiple specifications are optional,the ultimate vacuum can reach 2×10-3mbar,and the oil mist filter is standard.
● The vacuum pipelines are all high-vacuum stainless steel vacuum tubes, which can effectively prevent vacuum leakage and corrosion.
● The double anti-oil return device completely eliminates the damage and
equipment and samples.
● Automatic backfill air device,the system has a built-in High efficiency particulate air(HEPA)filter to ensure the complete cleanliness of backfill air.
● The vacuum stabilization system can stabilize the vacuum degree of the freeze-drying process through the micro-pass vacuum control valve to ensure that the samples will not be affected by excessive fluctuations in the vacuum degree.
● Condensed liquid collection and discharge system,automatically completes the collection and discharge of condensed liquid after freeze-drying.
Control SystemCharacteristic
● Control:Automatic/Manual
● Can store at least 100 independent freeze-drying programs,each program contains 32 program segments (Can be
customized according to user needs),each program segment corresponds to a processing stage (pre-freezing,main
drying,post-drying).and Include the following segment values:Cycles,shelf temperature,vacuum and safety pressure
● All the equipment can be recorded in real time and the corresponding freeze-drying curves and data tables can be generated after the end.The records of all data and curves comply with the corresponding regulations and standards.
● It has hierarchical management authority,hierarchical management allocation authority and usage process tracking authority
● Remote System
O Fully support 2G/4G/GSM/Wi-Fivarious connection modes
o Users can remotely view all data on the device and operate it
o Technicians can remotely perform maintenance and fault detection on equipment,and can remotely guide and train users
o Can remotely upgrade and change the system of the equipment
(Optional)Sufficient amount and time for the program to run itself
User function customization
Can be customized and modified according to user needs
Sterilization method
HzOz/steam sterilization
Note:”/”optional.Pilot models can be customized according to user needs
Document
Yingtai pilot-type freeze dryer completely simulates the technical requirements of the industrial freeze dryer,with a compact and reasonable design,a large redundancy range,and conforms to GMP and FDA standards.The ice condensation capacity is 4~18kg,and the WRL controller and liquid temperature control shelf are adopted,so that the process of pre-freezing and freeze-drying can be precisely controlled on the main machine,and the process results are quite comparable with the production machine.In addition to supporting the eutectic point test system,pressure rise and pressure comparison method to determine the freeze-drying end point and freeze-drying curve recording software,hallan pilot-type freeze dryer can also be equipped with engineering WRL control software to directly Graphical computer control the freeze-drying process.It can be configured with H202 sterilization and high-pressure steam sterilization orintegrated glove box system, which can be used for clean room operation through the wall.The cold trap and freeze-drying chamber are all designed with 316L stainless steel to ensure the cleanliness of the chamber and good ultimate vacuum and vacuum leakage rate to the greatest extent.
Cerillo’s Canopy Wireless Accessory Package includes the Canopy wireless device which enables wireless plate reader monitoring. It also comes with a companion software for retrieving, analyzing and communicating results from your Alto/Stratus microplate reader.
Document
Cerillo’s Canopy Wireless Accessory Package includes the Canopy wireless device which enables wireless plate reader monitoring. It also comes with a companion software for retrieving, analyzing and communicating results from your Alto/Stratus microplate reader.
Thymidylate Synthase (TS) is a crucial enzyme responsible for the synthesis of 2′-deoxythymidine-5′-monophosphate (dTMP) a precursor for thymidylate which is necessary for DNA replication and repair from 2′-deoxyuridine-5′-monophosphate (dUMP). In terms of cancer, TS is an important target for cancer treatment as the inhibition of TS and therefore nucleotide synthesis necessary for cell growth has shown to be a vital part for successful treatment against colorectal, pancreatic and breast cancers.