ProbeSure Master Mix combines class-leading performance with the most competitive prices in the market. ProbeSure Master Mix has provided users with accurate, robust, and consistent performance for many years. It has been carefully optimised to work over a wide range of reaction volumes and sample template qualities.
ProbeSure Master Mix is supplied at 2x concentration for convenience and is supplied with the ROX normalising dye at either high level (500 nM final concentration), low level (25 nM final concentration) or without ROX.
Other Products
Portable Low Speed Centrifuge
Product Info
Document
Product Info
TD4B Technical Parameter:
Max. Speed
5000rpm
Max. RCF
2635×g
Max. Capacity
4×50ml
Time Range
0~99min
RPM/RCF Convert
Yes
Noise (dB)
≤ 55
Temperature
Normal
Acc/Dec
10 Kinds
Speed Accuracy
±20r/min
Temperature Accuracy
/
Voltage(V/Hz)
AC 220V/110V 50HZ/60HZ
Size (W x D x Hmm)
280×220×175mm
Net Weight(Kg)
3.5KG
Certificates
CE,ISO & Calibration report are available
Matched Rotors for TD4B
Order No.
Rotor Type
Max Speed (rpm)
Max Volume(ml)
Max RCF(g)
NO31501
Angle Rotor
5000
4×50ml
2615
NO31502
Angle Rotor
5000
6×15/10ml
2635
6x7ml vacuum tube adapter
2635
6x5ml vacuum tube adapter
2635
Document
Features
1.Maintenance -free brushless motor
2.LCD display of Speed, RCF and time.
3.Adjustable speed from 300r/min to 5000r/min
4.Timer from 1s to 99min or continuous operation
5.For 6x15ml centrifuge tube &10ml/7ml/5ml/3ml blood collection tube or 4x50ml centrifuge tube
6.Lid automatically open at the end of run to revent sample warming and to reduce handling time.
7.10 Program stored in memory and editable by ender user.
8.10 Acceleration/ 10 Deceleration profiles ,with soft brake system to get the good separation effect.
9.Electric cover lock, compact design, super speed and imbalance protection.
Mal-amido-PEG5-alkyne is a PEG linker containing a maleimide group and an alkyne. The hydrophilic PEG spacer increases solubility in aqueous media. The alkyne group can react with azide-bearing compounds or biomolecules via copper catalyzed azide-alkyne Click Chemistry to yield a stable triazole linkage. The maleimide group will react with a thiol group to form a covalent bond, enabling the connection of biomolecule with a thiol. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Document
Mal-amido-PEG5-alkyne is a PEG linker containing a maleimide group and an alkyne. The hydrophilic PEG spacer increases solubility in aqueous media. The alkyne group can react with azide-bearing compounds or biomolecules via copper catalyzed azide-alkyne Click Chemistry to yield a stable triazole linkage. The maleimide group will react with a thiol group to form a covalent bond, enabling the connection of biomolecule with a thiol. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Aspergillus niger Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings