Q-PAGE™ Bis-Tris Precast Gel is a high-performance and easy to use precast polyacrylamide gel for electrophoresis in Bis-Tris buffer system (MOPS or MES). The optimized gel formula allows Q-PAGE™ Bis-Tris Precast Gel to show improved resolution, accurate results, and an extended shelf-life over conventional Laemmli Tris-HCl gels.
Q-PAGE™ Bis-Tris Precast Gels are available in gradient (4 to 12%) and fixed (8% and 12%) concentrations of polyacrylamide in 12-and 15-well formats. Two available cassette sizes, Mini (10 x 8.3 cm) and Midi (10 x 10 cm), are compatible with most popular protein electrophoresis systems. Q-PAGE™ Mini (QP2XXX) Gels are suitable for Bio-Rad® and other systems. Q-PAGE™ Midi (QP3XXX) Gels are suitable for Invitrogen® XCell SureLock® Mini-Cell, Invitrogen® Mini Gel Tank, Hoefer SE260, and other systems.
Detail
Description
Q-PAGE™ Bis-Tris Precast Gel is a high-performance and easy to use precast polyacrylamide gel for electrophoresis in Bis-Tris buffer system (MOPS or MES). The optimized gel formula allows Q-PAGE™ Bis-Tris Precast Gel to show improved resolution, accurate results, and an extended shelf-life over conventional Laemmli Tris-HCl gels.
Q-PAGE™ Bis-Tris Precast Gels are available in gradient (4 to 12%) and fixed (8% and 12%) concentrations of polyacrylamide in 12-and 15-well formats. Two available cassette sizes, Mini (10 x 8.3 cm) and Midi (10 x 10 cm), are compatible with most popular protein electrophoresis systems. Q-PAGE™ Mini (QP2XXX) Gels are suitable for Bio-Rad® and other systems. Q-PAGE™ Midi (QP3XXX) Gels are suitable for Invitrogen® XCell SureLock® Mini-Cell, Invitrogen® Mini Gel Tank, Hoefer SE260, and other systems.
Key Features
User-friendly gel cassette:
Numbered and framed wells for sample loading
Labeled warning sign and green tape as reminder
Enhanced gel performance:
Enhanced band sharpness
Better resolution of small proteins
Stable for shipping at ambient temperature
Easy compatibility:
Available as homogeneous and adjusted gradient gels for a wide range of protein separation.
Compatible with most popular protein electrophoresis systems
Storage and stability
Store Q-PAGE™ Precast Gels at 4°C for periods up to 12 months.
Do not freeze Q-PAGE™ Precast Gels. Remove tape and comb before electrophoresis.
Xenotropic murine leukemia virus-related virus (XMRV) is a gammaretrovirus. The virus was first described in 2006 and has since been isolated from human biological samples. XMRV belongs to the family Retroviridae and the genus gammaretrovirus. It has a single-stranded RNA genome that replicates through a DNA intermediate. The virus gets its name due to its close relationship with the murine leukemia viruses (MuLVs). The viral genome is approximately 8100 nucleotides in length and is 95% identical with several endogenous retroviruses of mice. While gammaretroviruses have well-characterized oncogenic effects in animals, they have not been shown to cause human cancers. However, XMRV was recently discovered in human prostate cancers and is the first gammaretrovirus known to infect humans. In addition to prostate cancer, a possible association with chronic fatigue syndrome has been reported, however it has yet to be established whether XMRV is a cause of this disease.
The causal role of XMRV in cancer has yet to be established and the virus does not appear to be capable of transforming cells directly. In prostate cancer, XMRV protein has been found in tumour-associated but nonmalignant stromal cells, but not in the actual prostate cancer cells. This raises the possibility that the virus may support tumorigenesis. In other studies, XMRV proteins and nucleic acids were found in malignant cells.
Storage Conditions and Product Stability All kit components can be stored for 1 year after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Interested in the analysis of DNA or RNA modifications? Then this DNA polymerase could help to analyze such modifications. The m6A sensitive DNA polymerase exhibits increased misincorporation rates opposite m6A, while unmodified adenine is not affected. This prevents the loss of methylation information during reverse transcription and thus allows direct m6A sequencing. For further information refer to the original publication.
Available upon request and for R&D use only – Contact Us
The m6A sensitive DNA polymerase is supplied as a 5 µM solution containing glycerol and is supplied together with 10x reaction buffer.
The enzyme can also be used for real-time cycling, when adding a suitable dye.
Document
Interested in the analysis of DNA or RNA modifications? Then this DNA polymerase could help to analyze such modifications. The m6A sensitive DNA polymerase exhibits increased misincorporation rates opposite m6A, while unmodified adenine is not affected. This prevents the loss of methylation information during reverse transcription and thus allows direct m6A sequencing. For further information refer to the original publication.
Urine Exosome and Free-Circulating RNA Isolation Kits
Product Info
Document
Product Info
Overview
Isolate all sizes of RNA, including microRNA, irrespective of size or GC content, without bias
Versatile sample input ranges
Isolate all sizes of free-circulating RNA, including microRNA
Bind and elute all RNA irrespective of size or GC content, without bias
The purified exosomal RNA is free from any circulating RNA-binding proteins
No phenol extractions, Proteinase K treatment nor carrier RNA required
No time-consuming ultracentrifugation, filtration nor special syringes are required
No precipitation reagents nor overnight incubation required
Concentrate isolated exosomal RNA and free-circulating RNA into a flexible elution volume ranging from 50 µL to 100 µL
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
These kits provide a fast, reliable and convenient method to sequentially isolate and concentrate exosomal RNA as well as Free-Circulating RNA from different urine sample volumes. The purification is based on spin column chromatography that employs Norgen’s proprietary resin. These kits are designed to isolate all sizes of RNA, including microRNA, irrespective of size or GC content, without bias. These kits provide a clear advantage over other available kits since they do not require any special instrumentation, protein precipitation reagents, extension tubes, phenol/chloroform or protease treatments. Moreover, the kits allow the user to elute into a flexible elution volume ranging from 50 µL to 100 µL. The RNA isolated from the purified exosomes is free from any protein-bound circulating RNA and is of the highest integrity. Moreover, the free-circulating, protein-bound, RNA is free from any exosomal RNA. The purified RNA can be used in a number of downstream applications including real time PCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, and expression array assays.
Urine Exosome and Free-Circulating RNA Isolation Mini Kit
For sample volumes ranging from 250 µL to 1 mL.
Urine Exosome and Free-Circulating RNA Isolation Midi Kit
For sample volumes ranging from 2 mL to 10 mL.
Urine Exosome and Free-Circulating RNA Isolation Maxi Kit
All sizes, including miRNA and small RNA (< 200 nt)
Elution Volume
50 – 100 µL
Time to Complete 10 Purifications
35 – 40 minutes
Average Yields*
Variable depending on the specimen
*Please check page 5 of the product insert for the average yields and the common RNA quantification methods.
Storage Conditions and Product Stability All buffers should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.
Important Note Urine samples stored at -70°C, -20°C or at 4°C will develop some precipitation due to the aggregation of some of the highly abundant proteins in urine. Eliminating these precipitates using centrifugation or filtration may cause the loss of exosomes. Furthermore, these precipitates may affect the quality of the purified nucleic acid. We recommend the use of Norgen’s Urine Preservative when collecting urine samples, which is designed for the preservation of nucleic acids and proteins in fresh urine samples at ambient temperatures. The components of the Urine Preservative allow samples to be stored for over 2 years at room temperature with no detected degradation of urine DNA, RNA or proteins. Norgen’s Urine Preservative is available as a liquid format in Norgen’s Urine Preservative Single Dose Ampules, as well as in a dried format in Norgen’s Urine Collection and Preservation Tubes.