This product supplies a simple and rapid extraction of total RNA from tissue and culture cells samples. The kit is based on superparamagnetic particles purification technology, no phenol-chloroform extraction or alcohol precipitation. The whole extraction processis only 60 minutes. Purified RNA is ready for downstream applications such as RT-PCR, virus RNA testing and so on. MagPure LQ Kit buffers can be used for both manual extraction process and automatic nucleic acid extraction machines.
Detail
Introduction
This product supplies a simple and rapid extraction of total RNA from tissue and culture cells samples. The kit is based on superparamagnetic particles purification technology, no phenol-chloroform extraction or alcohol precipitation. The whole extraction processis only 60 minutes. Purified RNA is ready for downstream applications such as RT-PCR, virus RNA testing and so on. MagPure LQ Kit buffers can be used for both manual extraction process and automatic nucleic acid extraction machines.
Details
Specifications
Features
Specifications
Main Functions
Isolation total RNA from tissue and cells and plant
Applications
RT-PCR, cDNA synthesis, second generation sequencing
Purification method
Polydisperse magnetic beads
Purification technology
Magnetic beads technology
Process method
Manual or automatic
Adaptive instrument
Nucleic acid extractor, pipetting workstation
Sample type
Animal tissue, human tissue, cultured cells, lymphocytes, ordinary plant tissue
Sample amount
Cells: 1 x 107Animal tissue: ≤20mgPlant tissue: ≤100mgYeast cell: ≤5 x 106
Yield
5-100μg
Principle
The Kit combines the speed and efficiency of silica-based technology with the convenient handling of magnetic particles for purification of total RNA. Samples are lysed and RNA is purified from lysates in one step through its binding to the silica surface of the particles in the presence of a chaotropic salt. The particles are separated from the lysates using a magnet and DNA is removed by treatment with RNase-free DNase. The magnetic particles are efficiently washed, and RNA is eluted in RNase-free water.
Advantages
High purity – OD 260 / 280 :1.9-2.0, OD 260 / 230 :1.5-2.0
Economy – less than 50% of the price of Qiagen and other imported products
Automatic – extraction without manual participation, saving time and effort
Universal – suitable for various animal tissues, cultured cells and conventional plant fungal tissues
Kit Contents
Contents
R662201
R662202
R662203
Purification Times
48 Preps
96 Preps
5 x 96 Preps
MagPure RNA Particles
1.7 ml
4.0 ml
18 ml
Proteinase K
24 mg
50 mg
240 mg
Protease Dissolve Buffer
1.8 ml
5 ml
15 ml
DNase I
600 μl
2 x 600 μl
10 x 600 μl
DNase Buffer
30 ml
40 ml
200 ml
RTL Lysis Buffer
40 ml
80 ml
400 ml
Buffer MCB*
18 ml
30 ml
150 ml
Buffer MW1*
44 ml
66 ml
2 x 220 ml
Buffer RW2*
20 ml
50 ml
2 x 100 ml
RNase Free Water
10 ml
30 ml
120 ml
Storage and Stability
MagPure RNA Particles and Proteinase K should be stored at 2–8°C upon arrival. DNase I shouldbe stored at -20°C. However, short-term storage (DNase I up to 1 weeks, MagPure RNA Particles and Proteinase K up to 8 weeks) at room temperature (15–25°C) does not affect their performance. The remaining kit components can be stored at room temperature (15–25°C) and are stable for atleast 18 months under these conditions.
Other Products
65L/ 90L/ 110L High-pressure Steam Autoclave
Product Info
Document
Product Info
Safety Features
1. User-Friendly Design: The chamber lid and tabletop are covered with heat-insulating resin materials, providing both protection against burns and an aesthetically pleasing appearance. The upward-opening flip-top door saves space, while the rounded corners prevent injury. The specially designed steam discharge and collection system minimizes steam burn risks and enhances operational convenience.
2. Interlock Mechanism and Safety Protection: The safety interlock system is designed to be more sensitive and secure. The chamber lid cannot be opened if there is pressure or steam inside the chamber. The lid can only be opened when the pressure gauge reads “0” MPa. The sterilizer will not start heating if the chamber lid is not properly locked. These features enhance the overall safety of the machine.
3. Over-temperature and Heating Protection: The system continuously monitors the temperature inside the sterilization chamber. If the temperature becomes too high or heating is abnormal, power will be automatically cut off to prevent overheating.
4. Automatic Fault Detection System: The machine performs an automatic self-check when powered on. If a fault occurs during operation, an audible alarm will sound, and a fault code will be displayed.
5. Lid Closure Check System: The system automatically detects whether the chamber lid is securely locked. If the lid is not properly locked, the sterilizer will not start.
6. Leakage, Over-current, and Short-Circuit Protection: If there is leakage in the heating elements or other components, or if over-current or short-circuit conditions occur, the system will automatically cut off power to prevent user injury.
7. Water Shortage and Independent Dry-Burning Protection: Equipped with a low water level sensor and independent dry-burning protection device, the system can monitor the water level in the chamber in real-time to prevent dry burning and avoid false readings. If the low water level sensor fails, the overheat and dry-burning protection system will automatically activate, cut off power to the heating ring, and sound an alarm to ensure safety.
8. Dual Pressure Protection: The system includes both a mechanical safety valve and an electronic over-pressure protection system. If pressure becomes abnormal, the system will relieve pressure and cut off power while sounding an alarm.
9. Back end Safety Testing: The system can be periodically tested for safety and protective measures.
10. Over-pressure Testing: Regular testing ensures that the instrument’s over-pressure protection system can automatically cut off power or that the safety valve can open to relieve pressure.
11. Performance Testing: The instrument’s safety performance has been tested by national authorized inspection agencies, and a test report is available.
Technical Parameters
Model
HB65A Standard TypeHB65B Auto Water Replenishment TypeHB65C Auto Drying Type
HB90AStandard TypeHB90BAuto Water Replenishment TypeHB90CAuto Drying Type
HB110AStandard TypeHB110BAuto Water Replenishment TypeHB110CAuto Drying Type
Capacity
65L
90L
110L
Dimensions (L × W × H) mm
664×660×994.5
664×660×994.5
664×660×1200
Sterilization Chamber Dimensions (Diameter × Height) mm
Timer Pre-set Range: Set operating time (year, month, day, hour, minute), check current time (year, month, day, hour, minute), total sterilization cycles, fault occurrence time, and code.
Pressure Gauge Display Range
0~0.6Mpa
Pressure
Chamber Design Pressure: 0.35 MPa; Each product comes with a quality certificate and a certificate issued by the special equipment manufacturing supervision and inspection department.
Pressure Safety Protection
Dual independent pipeline measurement and control, mechanical and electronic dual pressure protection
Fully automatic internal exhaust (see instructions for exhaust temperature settings), built-in large-capacity steam condensate collection bottle and water tank
Door lock interlocking device; Cover closing check; Dry burn protection; Water level sensor monitoring; Electronic over pressure protection; Mechanical safety valve; Over temperature and heating protection; Over current and short circuit protection; Leakage protection; Cooling lock; Burn injury safety protection; Automatic fault detection system
Printer, cooling fan, item temperature sensor, USB output
Stainless Steel Baskets
(φ360×230)1pcs(φ360×200)1pcs
(φ360×200)1pcs(φ360×400)1pcs
(φ360×200)2pcs(φ360×400)1pcs
Note: The upper limits for cooling lock door temperature and exhaust temperature are related to the boiling point.
Other Optional Accessories
1. Dot Matrix Printer: Capable of printing temperature, time, F0 value, and pressure data. USB data export and curve plotting.
2. Stainless Steel Basket with Base.
3. Pressure Sensor
4. Stainless Steel Bucket
5. Item Thermometer
6. 3Q Validation Adapter
Document
Features and functions:
1. Large-diameter sterilization chamber:The 40 cm large-diameter sterilization chamber provides an exceptionally spacious environment to meet a wide range of sterilization needs.
2. Sterilization temperature:105-138℃.
3. Exhaust control :After sterilization is complete, the exhaust valve can automatically open to release the exhaust at a pre-set temperature.
4. Verification interface: Provides temperature and pressure inspection ports for easy calibration.
5. Saturated steam monitoring:The system automatically monitors the expulsion of cold air to ensure a pure steam sterilization environment, guaranteeing optimal sterilization effectiveness.
6. Pressure performance:The chamber is designed to withstand a pressure of up to 0.35 MPa, and each unit is tested with a water pressure of up to 0.44 MPa. Advanced pressure protection ensures the safety load of the equipment.
7. Intelligent control system:The microcomputer chip-based intelligent control system monitors the temperature and pressure inside the sterilization chamber in real-time. The chamber lid can only be opened under safe temperature and pressure conditions. The system also provides fully automatic control of the sterilization process and allows for convenient maintenance, inspection, calibration, recording, and future upgrades.
8. Six preset programs:Includes six fixed programs for liquid sterilization and holding, solid sterilization and drying, agar melting and holding, and waste sterilization.
9. Memory storage system:Users can set their own parameters, create multiple programs, and access them at any time. The system allows for operation permissions to be set at three levels—user, administrator, and engineer—to facilitate effective use and management of the sterilizer.
10. Door-opening temperature: Each program can be set with a specific cooling lock door-opening temperature based on the thermal inertia of the sterilized items. This prevents users from opening the door when the items (especially liquid sterilized items) are still in an unsafe condition, thus avoiding burns.
11. Drying function: Thorough drying that meets CE standards, with a cooling lock mechanism.
12. One-touch inquiry function: Allows checking of current time, total number of sterilization cycles, fault occurrence time, and codes.
13. Scheduled start function: Allows you to set a start time so that the sterilizer automatically starts at the scheduled time.
CE-IVDR marked in accordance with the European Commission Regulation (EU) No. 2017/746.
Available for sale in Canada (Dx17200, Dx24300)
Ideal for use in in vitro diagnostic workflows
Extract high quality & quantity total RNA including miRNA
No phenol step required
Bind & elute all RNA irrespective of size or GC content, without bias
Very sensitive & linear down to a few cells without the need for carrier RNA
Convenient & fast spin column format
Available in 96-Well and 96-Well (Deep Well) formats for high throughput automation
Isolate from a wide variety of specimens
Purified RNA is suitable for a variety of downstream applications
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
Norgen’s Total RNA Purification Kits Dx provide rapid methods for the isolation and purification of total RNA from tissue samples, blood, plasma, serum, saliva, bacteria, yeast, fungi and viruses for subsequent in vitro diagnostic use. Extract high quality and purity RNA with excellent RIN values and A260/A280 suitable for downstream applications including qRT-PCR, RT-PCR, microarrays, NGS and more.
Total RNA Purification Kit Dx (Spin Column)
This kit is designed to be used with any downstream application employing enzymatic amplification or other enzymatic modifications of RNA followed by signal detection or amplification. Any diagnostic results generated using the RNA isolated with Norgen’s Total RNA Purification Kit Dx in conjunction with an in vitro diagnostic assay should be interpreted with regard to other clinical or laboratory findings.
Total RNA Purification 96-Well Kits Dx (High Throughput and High Throughput Deep Well)
Thess 96-well kits provide a rapid method for the high-throughput isolation and purification of total RNA in 30 minutes using vacuum manifold, plate centrifuge, or liquid handlers with vacuum capabilities. Total RNA can be isolated from a broad range of sample sources including cultured cells, tissues, blood, serum, plasma, bacteria, yeast, fungi, and viruses.
Intended Use
To minimize irregularities in diagnostic results, suitable controls for downstream applications should be used. Norgen’s Total RNA Purification Kits Dx are intended for use by professional users such as technicians, physicians and biologists experienced and trained in molecular biological techniques. Norgen’s Total RNA Purification Kits Dx do not provide a diagnostic result. It is the sole responsibility of the user to use and validate the kit in conjunction with a downstream in vitro diagnostic assay.
NOTE: This product is not available for sale in the United States.
Average Yield HeLa Cells (1 x 106 Cells) E. coli (1 x 109 cells) Brain (10 mg) Liver (10 mg) Blood (50 μL, Hamster)
15 μg 50 μg 9 μg 26 μg 1 μg
Maximum Amount of Starting Material: Whole Blood Plasma/Serum Bacteria Yeast Fungi Plant Tissue
100 µL150 µL1 x 109 cells1 x 108 cells 40 mg 40 mg
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. These reagents should remain stable for at least 1 year in their unopened containers.
Attogene’s Nano-clay Powder is comprised of thin layers and each layer has a thickness of one to a few nanometers length from a few hundred to several thousand nanometers. Nanparticles are utilized as fillers or additives in polymers for variety of desirable effects are receiving an increased interest for research and development. Different types of nanoparticles, such as nanocarbon, carbon nanotubes, nano-clays, and metal oxides, are recently employed to modify the polymer performance.
The viable interest is in the utilization of nano-clays for the alteration of polymeric material for numerous applications. This may be indicated from the increased commercial interest, and utilization of clay nanocomposites. It is an organic and hydrophilic. Moreover, the nanoclays are added in the polymers to increase the mechanical properties of polymers. In the nanocomposites, the permeability of the gases such as oxygen, carbon dioxide can be reduced by the addition of nanoclays. Nano clays have wide range of applications in food-packaging, pharmacy, used as a drug vehicle, textile industry etc.
Document
Promotes flocculation of cyanobacteria cell debris, binds residual phosphate compounds and promotes gradual settling of the cyanobacterial biomass on the sediment.