RNase activity in a convenient and sensitive colormetric assay that delivers results in real time. Great for Quality Testing for RNase contamination of materials and supplies.
Attogene has developed the first of its kind and patent pending technology that uses a novel RNA substrate tagged on the 5′ and 3′ end with a Biotin that is attached to our streptavidin colloidal gold reporter molecules and a test line tag. In the absence of RNases, the gold tagged RNA molecule will flow up the lateral flow strip and bind to the test line using an anti tag antibody (INDICATING that NO RNase is detected). When RNases are present, however, the RNA substrate is cleaved, and the 5′ and 3′ tags are spatially separated in solution cauing the test line to disapear.
This test can be used to rapidly and efficiently detect ribonucleases in both liquid and on solid surfaces and a perfect tool for monitoring mRNA vaccine manufacturing.
Other Products
OT-2 HEPA Filter H14 Replacement
Product Info
Document
Product Info
This H14 filter is a replacement for use with the OT-2 HEPA Module GEN1. The HEPA Module enables you to run sensitive contamination-prone applications on the OT-2.
Document
This H14 filter is a replacement for use with the OT-2 HEPA Module GEN1. The HEPA Module enables you to run sensitive contamination-prone applications on the OT-2.
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
The series of nucleic acid columns produced by Magen Biotech are based on carefully selected imported glass fiber membranes (GF/B, GF/D, GF/F). Columns production processes such as polypropylene injection molding materials, injection molding process, and downstream membrane packing and compression rings are strictly controlled. This is to ensure that the column has extremely high adsorption capacity and long-term stability. Compared with conventional products on the market, Magen’s columns are with varieties, and binding rate will not change when stored at room temperature for 4 years.
Details
Specifications
Features
Specifications
Recommended application
gDNA maxi yield preparation, total RNA maxi preparation
Preservation conditions
Room temperature
Stability
Up to 4 years
Filter membrane
High quality glass fiber filter GF/B, 4 layers
Membrane aperture
1.0μm
Maximum binding yield of plasmid
500 μg
Maximum yield of alcohol mediated binding
5 mg
gDNA or RNA yield (>30%ethanol)
Up to 5mg
Single liquid carrying capacity of column
20 ml
Minimum elution volume
800 μl
Withstand centrifugal force
3,000~5,000 x g
Centrifuge
Low speed centrifuge for 50mlcentrifuge tubes, >3000 x g, swing-out Rotor
Adsorption Mechanism
Based on the negatively charged DNA skeleton, it has a high affinity for positively charged glass fibers. In high salt and ethanol solutions, DNA/RNA binds to glass fiber and interacts with hydrophilic matrix on silica through hydrogen bond. DNA/RNA is tightly bound. All pollutants can be removed by washing solution. At high salt concentration, nucleic acids selectively bind to silica gel membrane, while other pollutants, mainly proteins, are removed by membrane washing.
Ordering information
CAT.No.
Product Name
Package
C13122
HiPure gDNA Maxi Column (4 x GF/B)with 50ml Collection Tubes
100/Bag
Purchase Guide
Item No.
Product Name
Membrane type/number of layers
Collection tubes
Plasmid DNA binding capacity (Physical adsorption)
Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.
Document
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
How to use: 1.Suspend 38g in 1 L of distilled water , stirring heated to boiling until completely dissolved, dispensing flask, 121 ℃ autoclave for 15min. 2.Diluted and treated samples.
Storage: Keep container tightly closed, store in a cool, dry place, away from bright light. Storage period of 3 years.