1.Microprocessor control, digital display, touch panel, parameters in running can be edited and change to display other running parameter and RCF.
2.Brushless frequency motor with simpler construction, more reliable performance, longer life and quietly running.
3.Automatic lid lock, LCD display, It can store 100 programs. super speed, over temperature protection and imbalance protection. The centrifuge body is made of high quality steel, safe and reliable.
4.Adapters are available by experiment requirements.
5.3 tiers protection steel cover, safe and reliable.
Attogene’s Lead Rapid Lab Lateral Flow Kit can be used for the screening of Lead in water and food samples at greater than or equal to 10 ppb in a laboratory setting. Unlike the field-based kit, the lab kit is intended for a more technical end user who will be evaluating samples in a laboratory setting.
Lead contamination is a serious worldwide environmental problem. As it is difficult to detoxify by chemical or biological methods, gradual Lead ion accumulation in the nervous and cardiovascular systems of the human body can subsequently cause serious diseases. Long-term health consequences of drinking Lead-contaminated food and water include brain, heart, kidney, lungs and immune system problems for adults, and the physical and mental development delays in infants and children. Attogene’s Lead Lateral Flow test gives results conforming of 10ppb or greater in 5-15 minutes.
This is a revolutionary product designed to make Lead testing in easy and affordable. This fast screening test kit contains 10 tests with everything needed for accurate results of unsafe lead levels. With reliable results in only 10 minutes, this test kit clearly gives results confirming Lead in water and conforming to the EPA guideline of 15 ppb (µg/L).
Sample Collection:
1. Take a first-draw sample
Immediately after opening a faucet or valve, collect a 250 mL sample. This sample should be from each tap used for consumption.
2. Take a flush sample
If first-draw sample results show elevated lead levels of 5 ppb or higher, collect a flush sample. To do this, ensure water has not been used for between 8 to 18 hours, then collect the sample at 30 seconds.
3. Take sequential samples
If you want to test a lead service line, collect 8 to 10 sequential samples, depending on how far the line is from the tap.
Standards and Regulations and recommendations for Lead
High Blood lead levels (i.e., greater than 700ppb) can cause serious health effects, including seizure, coma, and death. Blood levels as low as 100ppb have been associated with adverse effects on cognitive development, growth, and behavior among children aged 1-5 years.
Document
Screening of Lead in water samples at 5-10 ppb
Format: 10 tests (5 tests/5 controls)
Run Time: 15 Minutes
Isolate all sizes of circulating and exosomal RNA, including microRNA
Versatile plasma/serum input ranges
No phenol extractions
No carrier RNA
Bind and elute all RNA irrespective of size or GC content, without bias
Concentrate circulating RNA and exosomal RNA into a flexible elution volume
High quality, purified RNA is suitable for a variety of downstream applications, including Small RNA Sequencing. Find out more information on Norgen’s NGS services
Compatible with Streck Cell-Free RNA BCT® Tubes
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
These kits provide a fast, reliable and convenient method to purify and concentrate high quality, high purity and inhibitor-free cell-free circulating and exosomal RNA using a convenient spin column method. These kits can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate. Plasma samples prepared from blood collected on heparin should not be used, as heparin can significantly interfere with many downstream applications such as RT-PCR. The purified plasma/serum RNA is fully compatible with all downstream applications including PCR, qPCR, methylation-sensitive reverse transcription qPCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, expression array assays, and NGS.
Background
Plasma/Serum cell-free circulating RNA or exosomal RNA has the potential to provide biomarkers for certain cancers and disease states. Exosomes are 40 – 150 nm membrane vesicles, which are secreted by most cell types. Exosomes can be found in saliva, blood, urine, amniotic fluid and malignant ascitic fluids, among other biological fluids. Evidence has been accumulating recently that these vesicles act as cellular messengers, conveying information to distant cells and tissues within the body. These exosomes may play a functional role in mediating adaptive immune responses to infectious agents and tumours, tissue repair, neural communication and transfer of pathogenic proteins. For this reason exosomal RNAs may serve as biomarkers for various diseases including cancer. As the RNA molecules encapsulated within exosomes are protected from degradation by RNAses they can be efficiently recovered from biological fluids, such as plasma or serum.
Plasma/Serum RNA Purification Mini Kit
This kit can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate, from volumes ranging from 50 µL to 200 µL. The purified plasma/serum RNA is eluted in a flexible final volume of 10 µL to 25 µL.
Plasma/Serum RNA Purification Midi Kit
This utilizes a two column method, and can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate, from volumes ranging from 250 µL to 1.5 mL. The first column will handle the large volume input of bodily fluids that is followed by a concentration on a mini column for a final elution of 50 µL to 100 µL.
Plasma/Serum RNA Purification Maxi Kit
This kit can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate, from volumes ranging from 2 mL to 5 mL. The first column will handle the large volume input of bodily fluids that is followed by a concentration on a mini column for a final elution of 50 µL to 100 µL.
All sizes, including miRNA and small RNA (<200 nt)
Elution Volume
50-100 μL
Time to Complete 10 Purifications
35-40 minutes
Average Yields*
Variable depending on specimen
*Please check page 7 of the Product Insert for Average Plasma/Serum Yields and Common RNA Quantification Methods.
This kit is suitable for the isolation of RNA from fresh or frozen serum or plasma prepared from blood collected on either EDTA or Citrate. Plasma samples prepared from blood collected on heparin should not be used as heparin can significantly interfere with many downstream applications such as RT-PCR.
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.
TD4N Table Top 5000rpm Low Speed Laboratory Centrifuge
Product Info
Document
Product Info
TD4N Table Top 5000rpm Low Speed Laboratory Centrifuge
TD4N Features:
1. Microprocessor control, less noisily, it is widely used to qualitative analysis of blood serum, plasma and urea in the fields of hospital, blood center, laboratory and biochemistry.
2. Brushelss motor, free maintenance, no powder pollution, quick in speed up and down.
3. The flexible axle driven system which drive the rotor directly, smooth in operation and small vibration.
4. There are many rotors for your choice, suitable for different specifications meet customers’ different requirements of separation.
5. Micro-computer control system, digital display the RCF, time and speed.
6. Electric lid lock, compact design, super speed and imbalance protection.
TD4N Technical Parameter:
Max. Speed
5000rpm
Speed Accuracy
±20rpm
Max. Volume
6x100ml
Power Supply
AC110V/220V 50HZ/60HZ
Max. RCF
3460xg
Noise
≤55dBA
Timer
0~99min
Net Weight
18Kg
Dimension
540x370x280mm
Certifications
CE, ISO & Calibration report are available.
Warranty
1 Year
Matched Rotors for TD4N:
Order No.
Rotor Type
Max.Speed(rpm)
Max.Volume(ml)
Max.RCF(xg)
4N-1
Swing Rotor
5000
6x10ml
3460
4N-2
Angle Rotor
4000
30×7/5ml
2250
4N-3
Angle Rotor
4000
18×15/10ml
2250
4N-4
Angle Rotor
4000
24x10ml
2200
4N-5
Angle Rotor
4000
12×15/7/5ml
2150
4N-6
Angle Rotor
4000
12x20ml
2200
4N-7
Angle Rotor
5000
6x15ml
2540
4N-8
Angle Rotor
5000
12x15ml
3080
4N-9
Angle Rotor
5000
4x50ml
2520
4N-10
Angle Rotor
5000
6x50ml
2850
4N-11
Angle Rotor
5000
4x100ml
2630
4N-12
Angle Rotor
5000
6x100ml
3130