1. Microprocessor control, digital display, touch panel, parameters in running can be edited and change to display other running parameter and RCF.
2. Brushless frequency motor with simpler construction, more reliable performance, longer life and quietly running.
3.super speed, over temperature protection and imbalance protection. The centrifuge body is made of high quality steel, safe and reliable.
4. Adapters are available by experiment requirements.
5. 3 tiers protection steel cover, safe and reliable.
TD6C Technical Parameters:
Max speed
6000rpm
Max RCF
4110×g
Max volume
6×100ml
Power supply
AC 110V/220V 50HZ
Timer
0~99min
Noise
≤55dBA
Dimension(WxDxH)
485×320×320mm
Speed accuracy
±20rpm
Net Weight
18Kg
Certifications
CE, ISO & Calibration report is available
Matched Rotors for TD6C:
Order No.
Rotor
Max Speed (rpm)
Max Volume(ml)
Max. RCF(×g)
6C-1
Angle Rotor
6000
6×15ml/7ml/5ml
3660
6C-2
Angle Rotor
5000
12×15ml/7ml/5ml
3080
6C-3
Angle Rotor
6000
6×50ml
4110
6C-4
Angle Rotor
6000
4×50ml
3620
6C-5
Angle Rotor
6000
4×100ml
3790
6C-6
Angle Rotor
5000
6×100ml
3130
Other Products
HiDi® Taq 2x PCR Master Mix
Product Info
Document
Product Info
iDi® stands for High Discrimination of mismatches at the 3’-terminus of primers in PCR. This myPOLS Biotec enzyme family is optimized for this feature and is the first choice for applications that rely on this property such as allele-specific PCR (asPCR) or allele-specific amplification (ASA).HiDi® Taq 2x PCR Master Mix – ready to use mix simplifies your PCR setup. Only target-specific primers and template need to be added as the mix contains all components for a successful and reliable PCR. This ensures reproducible results, significantly reduces set-up times and the risk of pipetting errors.Please note: This PCR mix is also available as a mix with a nuclease deficient variant, featuring higher robustness towards potential PCR inhibitors and compatibility with real-time dyes such as our GreenDye.Benchmarking with products of competitors conducted by us and others show that the HiDi® DNA polymerase family is the first choice for highly selective PCRs, such as genotyping by allele-specific PCR, HLA genotyping, analysis of single CpG methylation sites or the detection of mutations in a high background of wild-type sequences. By using HiDi® Taq DNA polymerase, less than 10 copies of a mutation can be detected in a background of >10.000 wild-type copies straight away without any other tedious assay optimization.HiDi® Taq DNA polymerase harbours a nuclease function and therefor is also suitable for use with hydrolysis probes (TaqMan® probes etc.). It has also been shown that HiDi® DNA polymerase family is highly suitable for quality control and mutation identification in CRISPR-Cas or TALEN-based applications.Several independently conducted studies show that HiDi® Taq DNA polymerase is ideally suited for use in asPCR in numerous research areas ranging from mutation detection to genome editing. (read more)For research use and further manufacturing.In case you are aiming to use our RUO products as components or for your development of e.g. an IVD medical device, please contact us.
Casestudies: HiDi® DNA Polymerase: Applications from mutation detection to genome editing (read more)
Example Primer Design
Matching vs. mismatching nucleotide is placed at the 3′-end of the primer for best discrimination results.
Example Results – There´s no accounting for taste
Cilantro: some people love it in their food, some hate it. Here we are detecting a genomic SNP (rs72921001) in HeLa genomic DNA. This SNP is reported to be close to a number of genes coding for olfactory receptors. (Reference: Eriksson N. et al. (2012), “A genetic variant near olfactory receptor genes influences cilantro preference.”)
Considering, that only the C-allele specific primer is extended and yielding in a specific amplicon, we can conclude a genetic predisposition in disliking cilantro, as this SNP is significantly associated with detecting a soapy taste to cilantro.
Allele-specific PCRs were performed from 1 ng/µl of HeLa gDNA in the presence of a realtime dye, indicating the amplification of the C-allele specific primer only. The A-allele specific primer is discriminated, thus not amplified up to 50 cycles.
PCR products were subsequently analysed on a 2.5% agarose gel. Specific product is visualized by ethidium bromide staining at the amplicon length of 109 bp.
Document
HiDi® stands for High Discrimination of mismatches at the 3’-terminus of primers in PCR. This myPOLS Biotec enzyme family is optimized for this feature and is the first choice for applications that rely on this property such as allele-specific PCR (asPCR) or allele-specific amplification (ASA).
The BK virus is a member of the polyomavirus family. BK viral infections are typically asymptomatic in healthy individuals, however very mild symptoms may appear including mild respiratory infections and fever. Once an individual has been infected the virus disseminates to the kidneys and the urinary tract where it remains for the lifetime of the individual. Infections with BK virus in immunocompromised or immunosupressed patients are much more severe and may involve renal dysfunction. In fact, in kidney transplant patients the immunosupressive drugs required for the transplant may allow the virus to replicate within the graft, resulting in a disease called BK virus nephropathy (BKVN). It is thought that 1-10% of renal transplant patients progress to BK virus nephropathy (BKVN) and up to 80% of these patients are reported to have lost their grafts. The onset of nephritis can occur as early as several days post-transplant to as late as 5 years. The mode of transmission of the virus is not clear, however it has been suggested that BKV may be transmitted through respiratory fluids or urine, since infected individuals periodically excrete virus in the urine. This virus can be diagnosed by BKV blood & urine testing, in addition to carrying out a biopsy in the kidneys. PCR techniques are now widely used to identify the virus.
BKV TaqMan PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
BKV TaqMan PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Storage Conditions and Product Stability All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings