1. Microprocessor control, digital display, touch panel, parameters in running can be edited and change to display other running parameter and RCF.
2. Brushless frequency motor with simpler construction, more reliable performance, longer life and quietly running.
3.super speed, over temperature protection and imbalance protection. The centrifuge body is made of high quality steel, safe and reliable.
4. Adapters are available by experiment requirements.
5. 3 tiers protection steel cover, safe and reliable.
TD6C Technical Parameters:
Max speed
6000rpm
Max RCF
4110×g
Max volume
6×100ml
Power supply
AC 110V/220V 50HZ
Timer
0~99min
Noise
≤55dBA
Dimension(WxDxH)
485×320×320mm
Speed accuracy
±20rpm
Net Weight
18Kg
Certifications
CE, ISO & Calibration report is available
Matched Rotors for TD6C:
Order No.
Rotor
Max Speed (rpm)
Max Volume(ml)
Max. RCF(×g)
6C-1
Angle Rotor
6000
6×15ml/7ml/5ml
3660
6C-2
Angle Rotor
5000
12×15ml/7ml/5ml
3080
6C-3
Angle Rotor
6000
6×50ml
4110
6C-4
Angle Rotor
6000
4×50ml
3620
6C-5
Angle Rotor
6000
4×100ml
3790
6C-6
Angle Rotor
5000
6×100ml
3130
Other Products
Urine Exosome and Free-Circulating RNA Isolation Kits
Product Info
Document
Product Info
Overview
Isolate all sizes of RNA, including microRNA, irrespective of size or GC content, without bias
Versatile sample input ranges
Isolate all sizes of free-circulating RNA, including microRNA
Bind and elute all RNA irrespective of size or GC content, without bias
The purified exosomal RNA is free from any circulating RNA-binding proteins
No phenol extractions, Proteinase K treatment nor carrier RNA required
No time-consuming ultracentrifugation, filtration nor special syringes are required
No precipitation reagents nor overnight incubation required
Concentrate isolated exosomal RNA and free-circulating RNA into a flexible elution volume ranging from 50 µL to 100 µL
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
These kits provide a fast, reliable and convenient method to sequentially isolate and concentrate exosomal RNA as well as Free-Circulating RNA from different urine sample volumes. The purification is based on spin column chromatography that employs Norgen’s proprietary resin. These kits are designed to isolate all sizes of RNA, including microRNA, irrespective of size or GC content, without bias. These kits provide a clear advantage over other available kits since they do not require any special instrumentation, protein precipitation reagents, extension tubes, phenol/chloroform or protease treatments. Moreover, the kits allow the user to elute into a flexible elution volume ranging from 50 µL to 100 µL. The RNA isolated from the purified exosomes is free from any protein-bound circulating RNA and is of the highest integrity. Moreover, the free-circulating, protein-bound, RNA is free from any exosomal RNA. The purified RNA can be used in a number of downstream applications including real time PCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, and expression array assays.
Urine Exosome and Free-Circulating RNA Isolation Mini Kit
For sample volumes ranging from 250 µL to 1 mL.
Urine Exosome and Free-Circulating RNA Isolation Midi Kit
For sample volumes ranging from 2 mL to 10 mL.
Urine Exosome and Free-Circulating RNA Isolation Maxi Kit
All sizes, including miRNA and small RNA (< 200 nt)
Elution Volume
50 – 100 µL
Time to Complete 10 Purifications
35 – 40 minutes
Average Yields*
Variable depending on specimen
*Please check page 4 of the product insert for the average yields and the common RNA quantification methods.
Storage Conditions and Product Stability All buffers should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.
Important Note Urine samples stored at -70°C, -20°C or at 4°C will develop some precipitation due to the aggregation of some of the highly abundant proteins in urine. Eliminating these precipitates using centrifugation or filtration may cause the loss of exosomes. Furthermore, these precipitates may affect the quality of the purified nucleic acid. We recommend the use of Norgen’s Urine Preservative when collecting urine samples, which is designed for the preservation of nucleic acids and proteins in fresh urine samples at ambient temperatures. The components of the Urine Preservative allow samples to be stored for over 2 years at room temperature with no detected degradation of urine DNA, RNA or proteins. Norgen’s Urine Preservative is available as a liquid format in Norgen’s Urine Preservative Single Dose Ampules, as well as in a dried format in Norgen’s Urine Collection and Preservation Tubes.
RAA uses a novel RNA substrate tagged with a fluorescent reporter molecule (fluor) on one end and a quencher on the other. In the absence of RNases, the physical proximity of the quencher dampens fluorescence from the fluor to extremely low levels. When RNases are present, however, the RNA substrate is cleaved, and the fluor and quencher are spatially separated in solution. This causes the fluor to emit a bright green signal when excited by light of the appropriate wavelength. Fluorescence can be readily detected with a fluorometer. Since the fluorescence of the RAA Substrate increases over time when RNase activity is present, results monitored with a fluorometer can be evaluated kinetically. The sequence of the RAA Substrate has been carefully optimized to detect several RNases, including RNase A, RNase T1, RNase I, micrococcal nuclease, S1 nuclease, mung bean nuclease, and Benzonase.
Document
RNase activity in a convenient and sensitive fluorimetric assay that delivers results in real time. Great for Quality Testing for RNase contamination of materials and supplies.
ProbeSure Master Mix combines class-leading performance with the most competitive prices in the market. ProbeSure Master Mix has provided users with accurate, robust, and consistent performance for many years. It has been carefully optimised to work over a wide range of reaction volumes and sample template qualities.
ProbeSure Master Mix is supplied at 2x concentration for convenience and is supplied with the ROX normalising dye at either high level (500 nM final concentration), low level (25 nM final concentration) or without ROX.