TGL20 Table Top High Speed Refrigerated Centrifuge
Facebook
X
Pinterest
Email
Features: 1. Digital display indicates the speed,time,temperature and RCF. 2. Brushless DC motor in great torque, free maintenance,no powder pollution.quick in speed up and down. 3. There are many kinds of rotors for choice. 4. Automatically electric lid lock,super speed,over temperature protection and imbalance protection. 5. The centrifuge body is made of high-quality steel,safe and reliable.
Detail
TGL20 Technical Parameters
Max Speed
21000r/min
Max Volume
6×100ml
Timer
1~99h59min
Dimension
570×620×380mm
Speed Accuracy
±20r/min
Max RCF
30910×g
Noise
≤58dBA
Net Weight
84KG
Power supply
AC 220V, 50HZ 10A
Temperature Range
-20℃~40℃
Temperature Accuracy
±1℃
Matched Rotors for TGL20
Order no
Rotor
Max Speed(r/min)
Volume(ml)
Max RCF(*g)
G20-1
Fixed Rotor
16000
4×8PCR
15760
G20-2
Fixed Rotor
15000
6×8PCR
21420
G20-3
Fixed Rotor
16000
8×8PCR
17480
G20-4
Fixed Rotor
15000
12×8PCR
22930
G20-5
Fixed Rotor
21000
12×1.5/2ml
30910
G20-6
Fixed Rotor
15000
40×0.5ml
22920
G20-7
Fixed Rotor
17000
24×1.5/2ml
26460
G20-8
Fixed Rotor
13500
30×1.5/2ml
19340
G20-9
Fixed Rotor
13000
48×1.5/2ml
17930
G20-10
Fixed Rotor
16000
16×5ml
22020
G20-11
Fixed Rotor
16000
6×10ml
21500
G20-12
Fixed Rotor
15000
12×10ml
22680
G20-13
Fixed Rotor
16000
12×7ml
21380
G20-14
Fixed Rotor
13000
16×10ml
19490
G20-15
Fixed Rotor
10000
12×15ml
11840
G20-16
Fixed Rotor
13000
8×15ml(falcon)
17790
G20-17
Fixed Rotor
5000
24×15ml
3500
G20-18
Fixed Rotor
15000
8×20ml
22680
G20-19
Fixed Rotor
5000
30×15ml
3830
G20-20
Fixed Rotor
14000
6×30ml
19060
G20-21
Fixed Rotor
13000
6×50ml(falcon)
18840
G20-22
Fixed Rotor
13000
6×50ml(round)
18730
G20-23
Fixed Rotor
13000
4×85ml
18940
G20-24
Fixed Rotor
12000
6×70ml
15570
G20-25
Fixed Rotor
12000
4×100ml
14850
G20-26
Fixed Rotor
12000
6×100ml
16390
G20-27
Fixed Rotor
12000
24 pieces capillary vessel
15800
G20-28
Fixed Rotor
18000
30×0.5ml
26660
G20-29
Swing Rotor
13000
4×5ml
14960
G20-30
Vertical Rotor
16000
16×5ml
16540
G20-31
Vertical Rotor
14000
8×30ml
16450
G20-32
Microplate Rotor
4000
2×3×48(well)
2300
Other Products
AAV Purification Kits
Product Info
Document
Product Info
Overview
AAV Purification from any input – cell fraction or media fraction
High AAV recovery, up to 90%
No specialized equipment needed
Purification from a variety of AAV serotypes (including AAV6 and AAV9)
Yields highly active AAV for in vivo and in vitro experiments
Purification is based on spin column chromatography that uses Norgen’s resin separation matrix
Recombinant adeno-associated virus (AAV) vectors are highly promising tools for both in vitro and in vivo gene transfer. Norgen’s AAV Purification Kits provide fast and simple procedures for concentrating and purifying AAV vectors from cell lysate and cell culture media. Purification is based on precipitation onto Norgen Biotek’s proprietary resin. Contaminating cellular debris is largely removed from the sample via a centrifugation step, while contaminating DNA and RNA is reduced using enzymatic digestion. AAV vector purified in this manner is highly active for use in in vitro and in vivo transduction experiments.
AAV Purification Kit
Norgen’s AAV Purification Kit contains sufficient materials for 15 preparations (33.5 mL per prep of supernatant (SN) or a total of 500 mL of supernatant input). Approximately 1 mL of cell pellet can be purified per prep, up to a maximum of 15 mL of cell pellet in total for the entire kit. Up to 33X sample concentration.
AAV Purification Mini Kit
Each spin column is able to concentrate and purify AAV from 0.5-8 mL of cell pellet, cell culture media, or cells and culture media mixed together. Up to 50X sample concentration. AAV vector purified in this manner is highly active for use in in vitro transduction experiments, and is eluted into a small volume (200 µL). Preparation time for 4 samples is 1.5 hours, with 45 minutes of hands-on time.
AAV Purification Midi Kit
Each spin column is able to concentrate and purify AAV from 8 mL up to 45 mL of input consisting of cell pellet, cell culture media, or cells and culture media mixed together. Up to 50X sample concentration. AAV vector purified in this manner is highly active for use in in vitro transduction experiments, and is eluted into a small volume (1 mL). The kit may be used to purify up to 8 x 25 mL or 4 x 45 mL of samples using the included columns. Preparation time for 4 samples is approximately 2 to 2.5 hours, with 1.5 hours of hands on time.
AAV Purification Maxi Kit (Slurry Format)
Each spin column is able to concentrate and purify AAV from 45 mL to 90 mL of input consisting of cell pellet, cell culture media, or cells and culture media mixed together. Up to 200X sample concentration. AAV vector purified in this manner is highly active for use in in vitro transduction experiments, and is eluted into a small volume (1-10 mL) using the optional concentration step. The kit may be used to purify up to 1 x 900 mL samples or 10 x 45-90 mL samples using the included columns. Preparation time for 1 x 900 mL sample is approximately 2.5 to 3.5 hours, with an optional concentration step requiring an additional 30 min.
At least 1 x 1010 AAV particles as determined by qPCR
AAV Vector Serotype
Any
Average Recovery
> 80%
Input Type
Cells, media, or mixed
Input Volume
8 mL – 45 mL
Minimum Elution Volume
1 mL
Time to Complete 4 Purifications
2 – 2.5 hours
Storage Conditions and Product Stability DNAse I and RNAse A should be stored at -20°C upon arrival. Elution Buffer O should be stored tightly capped at 4°C upon arrival. All other solutions should be kept tightly sealed and stored at room temperature. Once opened, the solutions should be stored at 4°C. This kit is stable for 1 year after the date of shipment.
Component
Cat. 66100 (15 preps)
Cat. 63200 (20 preps)
Cat. 63300 (4-8 preps)
Cat. 63250 (1-10 preps)
Lysis Buffer S
5.5 mL
5.5 mL
5.5 mL
20 mL
DNAse I
–
2 x 25 uL
2 x 25 uL
210 μL
RNAse A
–
60 μL
60 μL
240 μL
HL-SAN Nuclease
102 μL
–
–
–
Binding Buffer A
20 mL
4 mL
4 mL
2 x 8 mL
Purification Solution C
60 mL
–
–
–
Purification Solution D
130 mL
–
–
–
Wash Solution C
2 x 130 mL
60 mL
60 mL
3 x 60 mL
Slurry E
12.5 mL
–
–
2 x 14.5 mL
Elution Buffer O
66 mL
8.5 mL
8.5 mL
66 mL
Protein Neutralizer
4 mL
4 mL
4 mL
4 mL
Spin Columns
–
20
–
–
Mini Spin Columns
–
20
–
–
Midi Spin Columns (grey contents) with Collection Tubes
–
–
8
10
Midi Spin Columns (white contents) with Collection Tubes
–
–
8
–
Maxi Spin Columns (grey contents) with Collection Tubes
–
–
–
10
Maxi Spin Columns (white contents) with Collection Tubes
Mucin 5AC (MUC5AC) is a secretory-type mucin found in columnar mucous cells of surface gastric epithelium and in goblet cells of the fetal and precancerous colon, but not in normal colon cells. MUC5AC expression is indicated in carcinomas wherein the type is defined as diffuse and infiltrative, and those located mainly in the antrum. Studies have also suggested a correlation between MUC5AC and colorectal signet-ring cell carcinoma, with overexpression of MUC5AC relating to the carcinogenesis, malignant potential, progression, and clinical behaviors.