The ExcelTaq™ 5X Blood Direct PCR Master Mix Kit is designed for amplifying targeted DNA directly from whole blood, eliminating the need for a lengthy DNA isolation process. ExcelTaq™ Blood Direct PCR Master Mix Kit is a unique blend of 5X concentrated mixture containing all the essential components of a PCR reaction. The ExcelTaq™ Blood Direct PCR Master Mix Kit also contains the PCR-friendly loading and tracking dye solution Orange G. The inclusion of Orange G tracking dye allows for a more convenient post-PCR gel electrophoresis analysis. ExcelTaq™ 5X Blood Direct PCR Master Mix Kit is capable of tolerating the presence of PCR interfering/ inhibiting substances in blood. The ExcelTaq™ 5X Blood Direct PCR Master Mix Kit is ideal for high-throughput screening of blood samples for high reproducibility. ExcelTaq™ 5X Blood Direct DNA PCR Master Mix Kit includes a pair of Positive Control Primers (CCR5) that are compatible with primate blood samples.
Detail
Description
The ExcelTaq™ 5X Blood Direct PCR Master Mix Kit is designed for amplifying targeted DNA directly from whole blood, eliminating the need for a lengthy DNA isolation process. ExcelTaq™ Blood Direct PCR Master Mix Kit is a unique blend of 5X concentrated mixture containing all the essential components of a PCR reaction. The ExcelTaq™ Blood Direct PCR Master Mix Kit also contains the PCR-friendly loading and tracking dye solution Orange G. The inclusion of Orange G tracking dye allows for a more convenient post-PCR gel electrophoresis analysis. ExcelTaq™ 5X Blood Direct PCR Master Mix Kit is capable of tolerating the presence of PCR interfering/ inhibiting substances in blood. The ExcelTaq™ 5X Blood Direct PCR Master Mix Kit is ideal for high-throughput screening of blood samples for high reproducibility. ExcelTaq™ 5X Blood Direct DNA PCR Master Mix Kit includes a pair of Positive Control Primers (CCR5) that are compatible with primate blood samples.
Features
5’→3′ DNA polymerase activity
No detectable 3’→5′ exonuclease (proofreading) activity
Generates PCR products with 3′-dA overhangs
High throughput PCR
High yield PCR
High reproducibility, with reduced pipetting errors
Compatible with most anticoagulants
Applications
Direct amplification of DNA from blood samples
High throughput screening without DNA purification
Suitable for multiplex PCR
Storage
Caution: Avoid Multiple Freeze/Thaw Cycles
4°C for 6 months -20°C for 24 months
Other Products
Phage DNA Isolation Kit
Product Info
Document
Product Info
Overview
Isolate high quality DNA from a broad variety of phage strains
High yields of total DNA
Fast and easy processing using a rapid spin-column format
No phenol or chloroform extractions or cesium chloride banding required
High yields of DNA recovered3-15 µg DNA from 106-1010 pfu/ mL of enriched phages
This kit provides a rapid spin column method for the purification of total DNA from a broad spectrum of bacteriophages propagated in bacteria grown in liquid cultures. The DNA is isolated without the use of phenol, chloroform or cesium chloride banding procedures. The spin-column based procedure is rapid and can be completed in less than 45 minutes. The kit is highly efficient for processing small volumes of phage supernatant (500 µL – 1 mL) and with the optional DNase and Proteinase K treatments phage DNA yields are maximized while host DNA contamination is minimized. Purified total phage DNA is of the highest integrity, and can be used in a number of downstream applications including PCR, qPCR, Restriction Fragment Length Polymorphism (RFLP), sequencing, cloning, Southern Blot and more.
3-15 µg DNA from 106-1010 pfu/mL of enriched phages
Time to Complete 10 Purifications
45 minutes
* Average yields will vary depending upon a number conditions used and developmental stage.
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 1 year after the date of shipment.
Robust lysis buffer is well-suited to even challenging samples such as pine needle, grape leaf, etc
Isolate total RNA (including microRNA) without phenol
Isolated RNA is of high quality, integrity and diversity
Also available in 96-well format for high throughput applications
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
Norgen’s Plant/Fungi Total RNA Purification Kit provides a rapid method for the isolation and purification of total RNA, including virus and viroid RNA, from a wide range of plants. Total RNA can be purified from fresh or frozen plant tissues, plant cells or filamentous fungi samples using this kit. All sizes of RNA are purified, including microRNA (miRNA) . The procedure is rapid and convenient.
The RNA is purified without the use of phenol or chloroform. The purified RNA is of the highest quality, and can be used in a number of downstream applications including real time PCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, and expression array assays.
Norgen’s Plant/Fungi Total RNA Purification Kit is also available in a 96-well (High Throughput) format for high throughput applications. Purification with the 96-well plates can be performed using either a vacuum manifold or centrifugation.
* Yield will vary depending on the type of sample processed.
* Yield will vary depending on the type of sample processed.
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
Select Plants and Fungi Tested with the Norgen Plant/Fungi Total RNA Purification Kits
Gel images of different ranges of library size selection. Sheared human genomic DNA was used as input.
.
Library size selection is an enrichment of a specific range of library sizes for NGS library preparations. The NGS library preparation is related to the quality of the sequencing data. Precise NGS library size selection can increase sequencing efficiency, improve data quality, and reduce costs.
There are two types of sequencing technologies: short-read sequencing and long-read sequencing. Short-read sequencing uses DNA libraries that contain small insert DNA fragments of similar sizes, usually several hundred base pairs. The sequencing efficiency can be improved if the DNA size selection is in the right range. Cat.# 20104S and 20104L are the best kits for NGS library size selection of illumina paired-end 100 (PE100) sequencing with 100-200 bp library inserts; Cat.# 20105S and 20105L are the best kits for NGS library size selection of illumina paired-end 150 (PE150) sequencing with 150-300 bp library inserts; and Cat.# 20106S and 20106L are the best kits for NGS library size selection of illumina paired-end 300 (PE300) sequencing with 300-600 bp library inserts.
Long-read sequencing uses a large DNA fragment as input and makes very long reads. Usually, library size selection is preferred to remove smaller fragments. Cat.# 20110S and 20110L are the best kits for long-read sequencing size selection with DNA sizes >5 kb, and Cat.# 20111S and 20111L are the best kits for long-read sequencing size selection with DNA sizes >10 kb.
The magnetic beads, or SPRI (Solid Phase Reversible Immobilization) beads, is well used for the purification of DNA due to their reversible DNA binding. The NGS library can be size-selected by the magnetic beads or SPRI beads. The properties of the magnetic beads can be changed for a specific range of DNA binding. The contaminants and other unwanted components in the libraries can also be removed during size selection.
Specific ranges of NGS libraries can be selected using magnetic beads with different buffer compositions. The first DNA-beads binding step, also called the right-side clean-up, removes large NGS library fragments. The large NGS library fragments that bind to the beads are discarded with the beads pellet. The desired NGS library fragments in the supernatant are transferred to a new well, and new beads are added to the supernatant for the second beads-DNA binding, also called the left-side clean-up. After the rinsing step, the NGS library fragments with the dual selection are eluted in water or an appropriate buffer. The magnetic beads method has great advantages over time-consuming column purification and tedious gel-based purification.
NGS library size selection with dual clean-ups.
.
Library size selection for long-read sequencing only requires a single clean-up. In this case, only the large library fragments are bound to the beads, while other small library fragments are discarded with the supernatant. The selected larger library fragments are eluted in water or an appropriate buffer after the rinsing step.
NGS library size selection with single clean-up for >5 kb and >10 kb libraries.