[TQ1201] ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, no ROX), 500 RXN
Facebook
X
Pinterest
Email
The ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, no ROX) is a ready-to-use reagent with all the essential components for quantitative real-time PCR (qPCR) except primers and templates. The master mix contains a highly stable hot-start Taq polymerase in an optimized buffer with dsDNA specific SYBR green fluorescent dye. Consequently, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, no ROX) features high stability during storage, even at 37°C for weeks. In addition to high sensitivity and signal intensity, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, no ROX) performs a low background/ high specificity qPCR results, as well as a better compatibility with fast PCR program.
With inert smart blue contrast dye, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, no ROX) is ready-to-use and greatly reduces pipetting errors, while largely improving the reproducibility of the process. The ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, no ROX) is also compatible with ROX reference dye if ROX is recommended by the manufacturer of the qPCR system. This master mix allows sensitive, precise amplification, real-time tracking of the amplification process, and simultaneous quantification for targeted DNA molecules.
Detail
Description
The ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, no ROX) is a ready-to-use reagent with all the essential components for quantitative real-time PCR (qPCR) except primers and templates. The master mix contains a highly stable hot-start Taq polymerase in an optimized buffer with dsDNA specific SYBR green fluorescent dye. Consequently, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, no ROX) features high stability during storage, even at 37°C for weeks. In addition to high sensitivity and signal intensity, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, no ROX) performs a low background/ high specificity qPCR results, as well as a better compatibility with fast PCR program.
With inert smart blue contrast dye, the ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, no ROX) is ready-to-use and greatly reduces pipetting errors, while largely improving the reproducibility of the process. The ExcelTaq™ 2X Fast Q-PCR Master Mix (SYBR, no ROX) is also compatible with ROX reference dye if ROX is recommended by the manufacturer of the qPCR system. This master mix allows sensitive, precise amplification, real-time tracking of the amplification process, and simultaneous quantification for targeted DNA molecules.
Features
High Stability
Fast Hot Start
High Sensitivity
Low Background
Suitable for Fast Program
Smart Blue Contrast Dye
Storage
Protect from light. Aliquot to avoid multiple freeze-thaw cycles. -20°C for 12 months
Other Products
Cytoplasmic and Nuclear RNA Purification Kit
Product Info
Document
Product Info
Overview
Excellent separation and purification of cytoplasmic and nuclear RNA
Convenient and fast spin column format
High quality and yield of RNA
Isolate full diversity of RNA (including microRNA) without phenol
Purified RNA is ready for any application including RT-PCR, qRT-PCR, RNA-Seq, arrays and more
Cytoplasmic RNA is free of DNA and ready for direct use in RT-PCR/qRT-PCR
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
This kit provides a rapid method for the isolation and purification of both cytoplasmic and nuclear RNA from cultured animal cells and small tissue samples. The kit can be used to isolate all sizes of RNA from the cytoplasmic and nuclear RNA fractions, including all small RNA species without any requirement for phenol. Included in the kit are sufficient reagents to perform either 50 cytoplasmic RNA preparations or 25 cytoplasmic and 25 nuclear RNA preparations. Ten samples can be processed in approximately 45 minutes. This kit is also available in a 100 prep size.
Background
In certain circumstances it is desirable to be able to isolate fractionated RNA as opposed to total RNA. For example, it may be preferable to isolate only mature, cytoplasmic RNA for some studies on expression profiling. Alternatively it may be desirable to isolate nuclear RNA in order to investigate and study pre-processed (non-spliced) RNA. Furthermore, this kit can be used to isolate RNA for downstream applications where it is necessary to avoid DNA contamination, since the cytoplasmic fraction has been shown to be free of all traces of genomic DNA.
RNA Yield HeLa (1 x 106) – Cytoplasmic RNA HeLa (1 x 106) – Nuclear RNA
15 µg ≤ 3.5 µg
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
NGS DNA Fragmentation & Library Prep Kit (illumina and MGI Platforms)
Product Info
Document
Product Info
The NGS DNA Fragmentation & Library Prep Kit (illumina and MGI Platforms) was developed for construction of high quality libraries for next generation sequencing. The kit uses intact genomic DNA (EDTA-free DNA or DNA resuspended in TE buffer) as input DNA without an additional DNA fragmentation step. Our technology provides a fast and simple workflow. DNA libraries can be generated around 2 hours with only 10 min hands-on time. Library multiplexing is possible.
NGS DNA Fragmentation & Library Prep Kit Workflow
The incorporation of DNA fragmentation in the kit makes it possible to directly use intact genomic DNA as input DNA without the need of mechanical DNA shearing or enzymatic DNA fragmentation. The NGS DNA Fragmentation & Library Prep Kit does not generate sequencing bias as compared to library using mechanical sheared DNA as input. Sequence coverage is also consistent between enzymatic shearing and mechanical shearing. The library size is inversely correlated with the incubation time of step 1 at 20°C.
Three index types are available for the kit of the illumina platform:
Non-index (Cat.# 30026): Libraries do not have index.
Index (Cat.# 30028): Each of the index primers contains a unique index sequence of 6 bases. Library multiplexing for 48 samples is possible. Index information can be downloaded here.
Unique dual index (Cat.# 30030): Library multiplexing for 96 samples is possible. With the unique features of our 4-Base Difference Index System, the index sequence is 8-base long and each index has 4 bases different from others. Our unique dual index primers effectively identify sequencing errors such as index hopping, mis-assignment of reads, and de-multiplexing errors etc. The unique dual index primers set consists of 96 pre-mixed unique pairs of index primers. Index information can be downloaded here.
Indexes are available for the MGI platform kits (Cat.# 34028).
Kit features:
1.5-hour protocol from intact genomic DNA to NGS library
Intact genomic DNA as input, DNA fragmentation is not needed.
Works with both EDTA-free DNA and DNA resuspended in TE buffer
Library conversion efficiency: 100 ng, 300 ng and 500 ng of intact genomic DNA were used as input.
The library size is inversely correlated with the incubation time of step 1 at 20°C.
NGS data comparison: enzymatic shearing versus mechanical shearing
Enzymatic shearing • DNA shearing and library prep: BioDynami NGS DNA Fragmentation & Library Prep Kit Mechanical shearing • DNA shearing: Covaris sonication • Library prep: BioDynami NGS DNA Library Prep Kit.
Document
The NGS DNA Fragmentation & Library Prep Kit (illumina and MGI Platforms) was developed for construction of high quality libraries for next generation sequencing. The kit uses intact genomic DNA (EDTA-free DNA or DNA resuspended in TE buffer) as input DNA without an additional DNA fragmentation step. Our technology provides a fast and simple workflow. DNA libraries can be generated around 2 hours with only 10 min hands-on time. Library multiplexing is possible.