Overview
- Detection kits for Trichomonas vaginalis
- Available in TaqMan format for analysis
Norgen’s Trichomonas vaginalis End-Point PCR Kit is designed for the detection of Trichomonas vaginalis specific DNA based on the use of end-point PCR technology. This kit is designed for research use only and not for use in diagnostic procedures. The kit includes Master Mix and primers for the specific amplification of a 335 nucleotide region of the Trichomonas vaginalis genome, as well as a positive control and a negative control to confirm the integrity of the kit reagents. In addition, the kit contains loading dye and a DNA ladder to facilitate analysis of the results.
The detection of Trichomonas vaginalis specific DNA is based on end-point PCR technology, utilizing polymerase chain reaction (PCR) for the amplification of specific Trichomonas vaginalis DNA sequences. For analysis of the PCR data, the PCR reaction is loaded on an agarose DNA gel along with the provided DNA ladder for qualitative analysis.
Trichomonas vaginalis TaqMan PCR Kit, 100 reactions
- Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
- Specific Primer and Probe mix for the pathogen/virus/viroid of interest
- Primer and Probe mix
- Positive and negative control to confirm the integrity of the kit reagents
Trichomonas vaginalis TaqMan PCR Probe/Primer Set and Controls, 100 reactions
- Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
- Nuclease-free water
- Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Details
Supporting Data
Figure 1 / 3
Click for expanded view
Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component | Cat. TM52050 (100 preps) | Cat. TM52010 (100 preps) |
---|---|---|
MDx TaqMan 2X PCR Master Mix | 2 x 700 μL | – |
Trichomonas vaginalis Primer & Probe Mix | 280 μL | 280 μL |
Trichomonas vaginalis Positive Control | 150 μL | 150 μL |
Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL |
Product Insert | 1 | 1 |