DBCO-PEG6-Maleimide is a PEG linker containing a DBCO moiety and a terminal primary maleimide group. The maleimide group will react with a thiol group to form a covalent bond, enabling the connection of biomolecule with a thiol. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
DBCO-PEG8-Maleimide is a PEG linker containing a DBCO moiety and a terminal primary maleimide group. The maleimide group will react with a thiol group to form a covalent bond, enabling the connection of biomolecule with a thiol. DBCO is commonly used for copper-free Click Chemistry reactions. Reagent grade, for research purpose. Please contact us for GMP-grade inquiries.
Product Details
Application:
DNA Nucleic Acid
Format:
NFO Kit
Kit Components:
Reagents,Buffer,Enzymes
Manufacturer:
Amp-future Bio
Product Name:
DNA Isothermal Rapid Amplification Kit (Colloidal Gold Test Strip Type)
Reaction Time:
5-20mins
Reaction Volume:
50μL
Sensitivity:
500-1000copies/ml
Shelf Life:
14 Months
Specificity:
High
Storage Conditions:
-20℃
Suitability:
Universal
High Light:
,
,
Payment & Shipping Terms
Minimum Order Quantity
48T
Price
USD$3.8/T
Packaging Details
16T/Bag,48T/Box
Delivery Time
6 working days
Payment Terms
T/T, MoneyGram
Supply Ability
100000T/Month
Product Description
【Principle Overview】
This kit is based on a rapid nucleic acid amplification technology at room temperature and constant temperature: at room temperature and constant temperature (generally 39℃~42℃), with the help of auxiliary proteins and single-strand binding proteins, the recombinase and primers form a complex; Source search and combine the target homology domain, at this time, a D-loop region is formed at the homology position and strand exchange begins; along with the dissociation of the recombinase from the complex, the polymerase also binds to the 3′ end of the primer and begins chain extension. Relying on the action of nfo enzyme, adding specific molecular probes designed according to the template, and using colloidal gold technology (sandwich method) can detect the final result.
【Primer design】
It is recommended to use primers with a length of 30-35 bp.Too short primers will affect the amplification speed and detection sensitivity;the 5′ end of the reverse primer is labeled with a modification group (commonly used biotin).
Primers are designed to avoid the formation of secondary structures that affect amplification; the length of the amplicon is recommended to be 150-500bp.
【Colloidal gold probe design】
In the middle of the forward and reverse primer,design a sequence of 46-52nt in length that is complementary to the target fragment; modify an antigen marker (typical FAM) at the 5′ end;mark a dSpacer (tetrahydrofuran, THF) in the middle of the 5′ end and the 3′ end ), as the recognition site of nfo;the 3′ end is labeled with a modification group, such as amine group, phosphate group or C3-Spacer, etc.
【Features】
This kit has the advantages of high sensitivity, strong specificity,and short reaction time (only 15 minutes),and the reaction components are in dry powder state,which is easy to operate and easy to store.
This reagent has low equipment requirement,and the reaction operation can be carried out in metal baths, water baths, etc.,and there is no need to purchase expensive exclusive equipment such as PCR amplifiers.
Composition | Content |
A buffer | 1.6mL×1Tube |
B buffer | 150μL×1Tube |
Positive control template-II | 100μL×1Tube |
Positive control probe and primer mix-II | 70μL×1Tube |
Reagent | 48 T |
Guide Manual | 1 Copy |
【Kit storage】
1. Storage conditions: storage temperature ≤ -20℃constant temperature environment, keep away from light and avoid heavy pressure;
2. Product validity period: 14 months;
3. See the outer packaging for the production date.
This kit is based on a rapid nucleic acid amplification technology at room temperature and constant temperature: at room temperature and constant temperature (generally 39℃~42℃), with the help of auxiliary proteins and single-strand binding proteins, the recombinase and primers form a complex; Source search and combine the target homology domain, at this time, a D-loop region is formed at the homology position and strand exchange begins; along with the dissociation of the recombinase from the complex, the polymerase also binds to the 3′ end of the primer and begins chain extension. Relying on the action of nfo enzyme, adding specific molecular probes designed according to the template, and using colloidal gold technology (sandwich method) can detect the final result.
The series of DNA Size Selection Kits (Magnetic Beads) were developed for DNA size selection using magnetic beads. A total of 11 kits are available, with different selection ranges spanning from 50 bp to over 10 kb. The kits provide a simple and quick approach for the enrichment of a specific range of DNA fragments. The kit workflow allows double-sided or single-sided size selection for specific size cutoffs.
.
DNA size selection is a selective capture of DNA fragments of a specific range of size for next-generation sequencing (NGS) library preparations, PCR, ChIP assay, DNA ligations, endonuclease digestions, adapter removal, and other genomics and molecular biology applications. DNA size selection is preferred after NGS library prep in most of the cases. The NGS library preparation is related to the quality of the sequencing data. Precise NGS library size selection can increase sequencing efficiency, improve data quality, and reduce costs.
There are two types of sequencing technologies: short-read sequencing and long-read sequencing. Short-read sequencing uses DNA libraries that contain small insert DNA fragments of similar sizes, usually several hundred base pairs. The sequencing efficiency can be improved if the DNA size selection is in the right range. Cat.# 20104S and 20104L are the best kits for NGS library size selection of illumina paired-end 100 (PE100) sequencing with 100-200 bp library inserts; Cat.# 20105S and 20105L are the best kits for NGS library size selection of illumina paired-end 150 (PE150) sequencing with 150-300 bp library inserts; and Cat.# 20106S and 20106L are the best kits for NGS library size selection of illumina paired-end 300 (PE300) sequencing with 300-600 bp library inserts.
Long-read sequencing uses a large DNA fragment as input and makes very long reads. Usually, library size selection is preferred to remove smaller fragments. Cat.# 20110S and 20110L are the best kits for long-read sequencing size selection with DNA sizes >5 kb, and Cat.# 20111S and 20111L are the best kits for long-read sequencing size selection with DNA sizes >10 kb.
The magnetic beads technology uses paramagnetic particles, also known as SPRI (Solid Phase Reversible Immobilization) beads, to bind DNA reversibly and selectively. DNA fragments can be size-selected and purified by changing the properties of the magnetic beads or SPRI beads. The magnetic beads can easily separate the beads-binding DNA from the contaminants and unwanted components in the samples. The samples after DNA size selection are free of contaminants such as buffer components, enzymes, proteins, salts, dNTPs, primers, and adapters. Our proprietary magnetic beads reagents improve yield, selectivity, and reproducibility.
Specific DNA fragments at a certain length range can be purified simply using magnetic separation with different beads components, avoiding tedious and time-consuming gel extraction and column-based purification. The magnetic beads method is popular for common DNA size selection, including library size selection. The first beads-binding step, referred to as the right-side clean-up, removes large DNA fragments. The large DNA fragments are bound to the beads and are discarded. The desired DNA fragments in the supernatant are transferred to a new well, and new beads are added to the supernatant for the second beads-binding, referred to as the left-side clean-up. The double-size selected DNA fragments are eluted after ethanol rinsing.
.
A single clean-up is needed for DNA size selection with large fragments. In this case, only the large DNA fragments are bound to the beads. The selected larger DNA fragments are eluted after ethanol rinsing.
.
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio
Privacy Policy | Terms of Use | Site Map