X396 Combo 384-well/96-Well Magnetic Plate with Integrated Cushion Base
Facebook
X
Pinterest
Email
Ideal magnet for all of your low volume needs. From Low elution 96-well PCR applications to 384-well, the X396 has you covered. No need to purchase two separate plates anymore. 96-well volumes as low as 5 µL are achieved from 96-well, PCR plates on the inside of the magnet, while the outside of each magnet will pull beads to well sides in 384-well plates.
Detail
Ideal magnet for all of your low volume needs. From Low elution 96-well PCR applications to 384-well, the X396 has you covered. No need to purchase two separate plates anymore. 96-well volumes as low as 5 µL are achieved from 96-well, PCR plates on the inside of the magnet, while the outside of each magnet will pull beads to well sides in 384-well plates.
ANSI/ SBS Footprint (127.75mm x 85.50mm) to fit into any automated liquid handling robot on bottom. ANSI/SBS footprint on top to accept all common microplates.
Integrated Cushion base for maximum recovery. Helps aid in set-up, robot positioning inconsistencies, and labware consumable inconsistencies
Features include solid aluminum alloy construction and hard coat anodized finish for years of trouble-free use, and compatible with any magnetic beads
This kit provides a simple and fast solution for the extraction of circulating nuclear acid from serum, plasma, and other cell-free liquid samples. Circulating nucleic acid refers to the free extracellular nucleic acid produced by cell apoptosis, of which fragments are generally below 1KB. The kit is based on silica gel column purification technology, which is no need for toxic phenol chloroform extraction and time-consuming alcohol precipitation during the extraction. The obtained Circulating Nucleic Acid can be directly used for quantitative PCR, liquid or solid phase chip analysis, hybridization, and SNP detection. HiPure Circulating DNA/RNA Kit adopts a unique solution system and multiple layers of filter membranes with different pore sizes, which can efficiently process large volumes of serum and plasma samples and capture extremely small amounts of free nucleic acids.
Details
Specifications
Features
Specifications
Main Functions
Isolation both Circulating DNA/RNA (include miRNA) from 1-5 ml serum and plasma
Applications
qPCR / RT-PCR, liquid or solid-phasechip analysis, hybridization and SNP detection
Purification method
Midi spin column
Purification technology
Silica technology, DNA filtration technology
Process method
Manual (centrifugation or vacuum)
Sample type
serum, plasma, and other cell-free liquid samples
Sample amount
1-5 ml
Elution volume
≥20μl
Time per run
≤100 minutes
Liquid carrying volume per column
4 ml
Binding yield of column
1 mg
Principle
This kit is based on silica gel column technology. Serum or other liquid samples are lysed and digested in buffer CFL. After adding buffer CFP, the protein is removed by centrifugation to obtain the supernatant. Isopropanol is added to precipitate the total nucleic acid and transferred to the column for filtration. DNA / RNA is adsorbed on the membrane of the column, while the protein is not adsorbed and removed with the filtrate.The column is washed with buffer MGW1 to remove protein and other impurities, and then washed with buffer RW2 to remove salt. Finally, DNA / RNA is eluted by low salt buffer. The eluted DNA / RNA can be directly used for quantitative PCR/ RT-PCR, liquid or solid-phase chip analysis, hybridization and SNP detection.
Advantages
High yield – most optimized process to obtain maximum free RNA and small RNA
High concentration – low elution volume (>20μl) to ensure nucleic acid concentration
High purity – low alcohol combination, completely remove inhibitor and protein pollution
High recovery – silica gel column technology can recover nucleic acid molecules at the level of PG
Large volume – 1-2ml serum and plasma samples can be processed at one time
Kit Contents
Contents
R431602
D431603
Purification Times
50 Preps
250 Preps
HiPure RNA Micro Columns
50
5 x 50
HiPure Viral Midi Columns
50
5 x 50
15 ml Collection Tubes
50
5 x 50
2ml Collection Tubes
50
5 x 50
Buffer CFL
150 ml
2 x 375 ml
Buffer CFP
30 ml
150 ml
Buffer MGW1*
100 ml
2 x 250 ml
Buffer RW2*
2 x 50 ml
5 x 100 ml
RNase Free Water
10 ml
50 ml
Storage and Stability
The kit components can be stored at room temperature (15–25°C) and are stable for at least 18 months under these conditions.
Document
This kit provides a simple and fast solution for the extraction of circulating nuclear acid from serum, plasma, and other cell-free liquid samples. Circulating nucleic acid refers to the free extracellular nucleic acid produced by cell apoptosis, of which fragments are generally below 1KB. The kit is based on silica gel column purification technology, which is no need for toxic phenol chloroform extraction and time-consuming alcohol precipitation during the extraction. The obtained Circulating Nucleic Acid can be directly used for quantitative PCR, liquid or solid phase chip analysis, hybridization, and SNP detection. HiPure Circulating DNA/RNA Kit adopts a unique solution system and multiple layers of filter membranes with different pore sizes, which can efficiently process large volumes of serum and plasma samples and capture extremely small amounts of free nucleic acids.
The HiPure Plant RNA Midi Kit provides fast purification of high-quality RNA from plants, cell, tissues, and yeast using silica-membrane spin columns with a binding capacity of 1mg RNA. There is no need for phenol / chloroform extractions and time-consuming steps such as CsCl gradient ultracentrifugation or precipitation with isopropanol or LiCl. RNA purified using the RaPure Total RNA Purification System can be used for applications such as RT-PCR, Northern blotting, poly A+ RNA (mRNA) purification, nuclease protection, and in vitro translation.
Details
Specifications
Features
Specifications
Main Functions
Isolation total RNA from <1g simple plant sample without chloroform
Applications
RT-PCR, qPCR, Northern hybridization, second generation sequencing, nucleic acid protection, in vitro translation
Purification method
Midi spin column
Purification technology
Silica technology, DNA filtration technology
Process method
Manual (centrifugation or vacuum)
Sample type
Plant leaves, roots, stems, fruits, fungi, etc.
Sample amount
0.5-1 g
Elution volume
≥400μl
Time per run
≤40 minutes
Liquid carrying volume per column
4ml
Binding yield of column
1mg
Principle
The Kit isolates total RNA from up to 1g plant tissue. A short workflow enables RNA isolation with genomic DNA removal in less than 40 min. Samples are first lysed and homogenized. The lysate is passed through a DNA Mini column, ethanol is added to the flow-through, and the sample is applied to a RNA column. RNA binds to the membrane and contaminants are washed away. High-quality RNA is eluted in as little as 400µl water using the Kit.
Advantages
Efficient removal of DNA – unique genomic DNA removal column without DNase treatment
High quality – high purity total RNA can be directly used in various sensitive downstream applications
Fast – medium isolation of several samples can be completed in 40 minutes
Safe – no phenol chloroform extraction required
Sensitive – RNA can be recovered at the level of PG
Broad spectrum – various types of plant samples can be processed by diversity of operating procedures
Kit Contents
Contents
R415202
D415203
Purification Times
20 Preps
100 Preps
HiPure DNA Midi Column II
20
100
HiPure RNA Midi Columns II
20
100
15ml Collection Tubes
40
200
Buffer RLC
120 ml
550 ml
Buffer PRC1
120 ml
550 ml
Buffer RW1
70 ml
400 ml
Buffer RW2*
20 ml
100 ml
RNase Free Water
30 ml
120 ml
Storage and Stability
The Kit can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions. Make sure that all buffers are at room temperature when used. During shipment, crystals or precipitation may form in the Buffer RLC/PRC1. Dissolve by warming buffer to 37°C.
Purchase Guide
1. When dealing with woody or uncommon samples, R4150 is recommended first. R4150 contains two polysaccharide/polyphenol lysis buffer, which is the most universal product.
2. R4151 is recommended for handling common economic crop samples for the first time. Strong lysis solution can be used to process easy-extraction samples. The amount of corn or rice leaves samples can reach up to 300mg.
3. R4165 adopts CTAB/chloroform method, which can also handle a large number of difficult-to-extraction plants, but requires contact with chloroform substitutes, which is less safe than other kits. This kit uses DNase Ⅰ to remove DNA, which is also a good choice for extracting polysaccharide/polyphenol-rich plant samples.
4. R4014 is recommended for fruit/starch plant samples, which uses improved trizol pre-treatment, single column operation and is more economical.
Select the right purification kit to get impactful results:
The HiPure Plant RNA Midi Kit provides fast purification of high-quality RNA from plants, cell, tissues, and yeast using silica-membrane spin columns with a binding capacity of 1mg RNA. There is no need for phenol / chloroform extractions and time-consuming steps such as CsCl gradient ultracentrifugation or precipitation with isopropanol or LiCl. RNA purified using the RaPure Total RNA Purification System can be used for applications such as RT-PCR, Northern blotting, poly A+ RNA (mRNA) purification, nuclease protection, and in vitro translation.
Permagen’s Dual Volume 0.2 mL PCR Strip separator uses the same magnet configuration as our MSR812 rack above, however, when using the opposite side, the magnets are positioned towards the bottom of the tubes allowing low elution’s to be achieved. Angled tube holes allow clean area at the front of the well for clean, fast aspiration without the concern of disturbing bead pellets Features include solid aluminum alloy design with hard coat finish for years of trouble-free use, rubber feet to help prevent slipping on work bench, less tippy than common plastic products, and fast separations using any magnetic beads
Permagen’s Dual Volume 0.2 mL PCR Strip separator uses the same magnet configuration as our MSR812 rack above, however, when using the opposite side, the magnets are positioned towards the bottom of the tubes allowing low elution’s to be achieved. Angled tube holes allow clean area at the front of the well for clean, fast aspiration without the concern of disturbing bead pellets Features include solid aluminum alloy design with hard coat finish for years of trouble-free use, rubber feet to help prevent slipping on work bench, less tippy than common plastic products, and fast separations using any magnetic beads