X396 Combo 384-well/96-Well Magnetic Plate with Integrated Cushion Base
Facebook
X
Pinterest
Email
Ideal magnet for all of your low volume needs. From Low elution 96-well PCR applications to 384-well, the X396 has you covered. No need to purchase two separate plates anymore. 96-well volumes as low as 5 µL are achieved from 96-well, PCR plates on the inside of the magnet, while the outside of each magnet will pull beads to well sides in 384-well plates.
Detail
Ideal magnet for all of your low volume needs. From Low elution 96-well PCR applications to 384-well, the X396 has you covered. No need to purchase two separate plates anymore. 96-well volumes as low as 5 µL are achieved from 96-well, PCR plates on the inside of the magnet, while the outside of each magnet will pull beads to well sides in 384-well plates.
ANSI/ SBS Footprint (127.75mm x 85.50mm) to fit into any automated liquid handling robot on bottom. ANSI/SBS footprint on top to accept all common microplates.
Integrated Cushion base for maximum recovery. Helps aid in set-up, robot positioning inconsistencies, and labware consumable inconsistencies
Features include solid aluminum alloy construction and hard coat anodized finish for years of trouble-free use, and compatible with any magnetic beads
The HiPure Liquid RNA & miRNA Kit integrates phenol/guanidine-based sample lysis and silica membrane purification of total RNA. MagZol LS Reagent, included in the kits, is a monophasic solution of phenol and guanidine thiocyanate designed to facilitate lysis of liquid sample and inhibit RNase. The high lysis efficiency of the reagent and the subsequent removal of contaminants by organic phase extraction enable the use of up to 0.25ml liquid sample per mini spin column.
Details
Specifications
Features
Specifications
Main Functions
Isolation total RNA from 0.25ml body fluids using column and MagZol LS reagent
Applications
qPCR / RT-PCR, liquid or solid-phasechip analysis, hybridization and SNP detection
0.25ml liquid samples are homogenized in 0.75ml MagZol LS Reagent. After addition of chloroform, the homogenate is separated into aqueous and organic phases by centrifugation. The upper, aqueous phase is extracted, and ethanol is added to provide appropriate binding conditions. The sample is then applied to the spin column, where the total RNA (up to 100 µg) binds to the membrane and phenol and other contaminants are efficiently washed away. High-quality RNA is then eluted in 30–100µl of RNase-free water.
Advantages
High quality – high purity total RNA can be directly used in various sensitive downstream applications
Fast – isolation of several samples can be completed in 40 minutes by using column purification method
Safety – no phenol chloroform extraction required
Sensitive – direct lysis of blood, plasma and other samples without separation of leukocytes
Kit Contents
Contents
R416302
R416303
Purification Times
50 Preps
250 Preps
HiPure RNA Mini Columns
50
250
2ml Collection Tubes
50
2 x 125
MagZol LS Reagent
60 ml
270 ml
Buffer RWC
20 ml
60 ml
Buffer RW2*
20 ml
2 x 50 ml
RNase Free Water
10 ml
30 ml
Storage and Stability
MagZol LS Reagent should be stored at 2-8°C upon arrival. However, short-term storage (up to 24 weeks) at room temperature (15-25°C) does not affect their performance. The remaining kit components can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
Document
The HiPure Liquid RNA & miRNA Kit integrates phenol/guanidine-based sample lysis and silica membrane purification of total RNA. MagZol LS Reagent, included in the kits, is a monophasic solution of phenol and guanidine thiocyanate designed to facilitate lysis of liquid sample and inhibit RNase. The high lysis efficiency of the reagent and the subsequent removal of contaminants by organic phase extraction enable the use of up to 0.25ml liquid sample per mini spin column.
A highly efficient, easily automated PCR purification system that delivers superior quality DNA with no salt carryover. Requiring no centrifugation or filtration. This kit can be easily used in manual and automated 96 or 384-well formats.
Details
Specifications
Features
Specifications
Main Functions
Recover 100-400μl DNA/ RNA from PCR products / enzymatic reaction solution / or crude DNA / RNA
Applications
Automatic sequencing, enzyme digestion, PCR and labeling
The MagPure method contains magnetic particles in an optimized binding buffer to selectively bind DNA fragments 100bp and larger toparamagnetic beads. Excess primers, nucleotides, salts, and enzymes can be removed using a simple washing procedure.
Advantages
High recovery efficiency – up to 80% DNA recovery
Kit Contents
Contents
D500301
D500302
D500303
Purification Times
50 Preps
500 Preps
5000 Preps
Buffer AL
10 ml
60 ml
550 ml
Buffer BD*
5 ml
25 ml
2 x 100 ml
MagPure RNA Particles
1.2 ml
12 ml
120 ml
RNase Free Water
5 ml
30 ml
250 ml
Storage and Stability
MagPure RNA Particles should be stored at 2-8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect its performance. The remaining kit components can be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions. The entire kit can be stored at 2-8°C, but in this case buffers should be redissolved before use. Make sure that all buffers are at room temperature when used.
Document
A highly efficient, easily automated PCR purification system that delivers superior quality DNA with no salt carryover. Requiring no centrifugation or filtration. This kit can be easily used in manual and automated 96 or 384-well formats.