ExcelRT™ Reverse Transcription Kit is a complete, efficient and convenient kit to synthesize high quality first strand cDNA. This kit contains ExcelRT™ Reverse Transcriptase, which is able to synthesize the first strand cDNA at 37~50°C. The ExcelRT™ Reverse Transcriptase is a recombinant Moloney Murine Leukemia Virus (M-MLV) reverse transcriptase, which is designed to reduce RNase H activity and create better thermal stability. This kit also contains RNAok™ RNase Inhibitor, which is active against RNase A, RNase B, and RNase C. This product is supplied with oligo (dT)20 and random hexamers, which are used to synthesize cDNA from poly(A) tailed mRNA and total RNA, respectively.
Detail
Description
ExcelRT™ Reverse Transcription Kit is a complete, efficient and convenient kit to synthesize high quality first strand cDNA. This kit contains ExcelRT™ Reverse Transcriptase, which is able to synthesize the first strand cDNA at 37~50°C. The ExcelRT™ Reverse Transcriptase is a recombinant Moloney Murine Leukemia Virus (M-MLV) reverse transcriptase, which is designed to reduce RNase H activity and create better thermal stability. This kit also contains RNAok™ RNase Inhibitor, which is active against RNase A, RNase B, and RNase C. This product is supplied with oligo (dT)20 and random hexamers, which are used to synthesize cDNA from poly(A) tailed mRNA and total RNA, respectively.
Features
Contains all components for reverse transcription
High yield
Thermostable, up to 50°C, during first strand synthesis
High processivity, generating cDNA up to 8 kb
Reduced RNase H ribonuclease activity
Application
Generation of first strand cDNA from total RNA or mRNA.
Suitable for generating cDNA from RNA with strong secondary structure which can be reduced at temperature up to 50°C.
Storage
-20°C for 24 months
High yield
High sensitivity
Thermostable, up to 50°C, during first strand synthesis
Contents
ComponentVolume ExcelRT™ Reverse Transcriptase (200 U/μl) 100 μl RNase Inhibitor (20 U/μl)100 μl 5X RT Buffer (DTT)500 μl dNTPs Mix (10 mM each)200 μl Oligo (dT)20 (50 μM)100 μl Random Hexamers (100 μM)100 μl DEPC-Treated H2O 1 ml x 2
Storage Buffer
Reverse Transcriptase: 20 mM Tris-HCl (pH 7.5), 200 mM NaCl, 0.1 mM EDTA, 1 mM DTT, stabilizer and 50% (v/v) glycerol
RNase Inhibitor: 40 mM HEPES-KOH (pH 7.5), 100 mM KCl, 8 mM DTT, 0.1 mM EDTA, stabilizer and 50% (v/v) glycerol
5X RT buffer (DTT)
250 mM Tris-HCl (pH 8.3), 375 mM KCl, 15 mM MgCl2 and 50 mM DTT
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Exceptional value for money
Rapid detection of all clinically relevant subtypes
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings
50 & 150 reactions
Convenient optimized on-column DNase treatment using Norgen’s RNA Purification Kits
Also includes protocol for digestion in-solution followed by RNA Clean-Up
Guaranteed RNase-Free
Includes Enzyme Incubation Buffer
Cat. 25710 contains one vial of 1,600 units and Cat. 25720 contains 4 vials (1,600 units/vial)
Norgen’s RNA purification kits isolate total RNA with minimal amounts of genomic DNA contamination. However, for some sensitive downstream applications, it may be desirable to remove all traces of residual DNA. Norgen’s RNase-free DNAse I Kit, with Enzyme Incubation Buffer, can be used for optional on-column DNase digestion with any of Norgen’s RNA purification kits. Alternatively, after isolating total RNA using one of Norgen’s RNA purification kits, the RNA elution can be treated with this DNase I. The RNA can then be purified from the DNase using Norgen’s RNA Clean-Up and Concentration Kit (Cat# 23600), and the RNA can then be used in downstream applications.
Details
Each RNase-Free DNase I Kit is supplied complete with sufficient enzyme and enzyme incubation buffer for 50 or 200 reactions.
Storage Conditions The DNase I provided is in lyophilized form. It is stable for at least 3 months if stored at room temperature. However, it is recommended to store the DNase I vial at 2 – 8ºC (or below) upon receipt to maintain stability beyond 3 months. Buffer DR and Enzyme Incubation Buffer can be stored at room temperature. After reconstitution with Buffer DR (see product manual), the DNase I should be stored at -20ºC. All reagents should remain stable for at least 1 year in their unopened containers at the appropriate storage temperature.
Silicone oil thermal conductive shelf, high-precision processing method of upper and lower clamping, shelf temperature uniformity can reach ±0.5°c
Integrated cavity:
Integrated chamber, the shelf and cold trap are located in the same chamber, the steam conduction is faster and the freeze-drying effect is better
Refrigerating and heating control system:
Using thermally conductive silicone oil with a high temperature range and precise PID control algorithm, the control accuracy can reach ±0.5°C. Sample shelf temperature range: -70°C~ +80°C
Freeze-drying endpoint testing system:
The pressure comparison method is used to determine the freeze-drying end point. The freeze-drying end point test can be automatically performed after the analytical drying stage to ensure that the moisture content of the material reaches the standard requirements.
Vacuum precise control and adjustment system:
The sublimation and analytical drying processes are controlled and adjusted with high precision to make the freeze-drying process warmer and the sample sublimation more reliable.
Pulse backfill system:
Three backfilling modes can be selected: slow, medium and fast, which avoids the problem of effective substances being blown away and lost due to the aeration of granular and flocculent materials after freeze-drying.
Manual automatic mode selection:
Manual mode is used to explore process parameters (strong human intervention), automatic mode is used in the mature stage of the process, one-click operation, simple and convenient
Data recording and analysis system:
Through the PC host computer, all operating parameters and background parameters of the equipment can be recorded in real time, and all parameter action changes and action changes of operating components can be recorded.
Freeze-drying process recipe storage function:
The host can store 60 sets of fixed or user-defined freeze-drying process recipes, and the PC can store >10,000 programs (depending on the computer hard drive)
Eutectic point test function:
The eutectic point temperature of the product can be tested offline and online, and the spectrum can be analyzed manually or automatically (optional)
Remote control system:
The operating status of the device can be monitored remotely, and the device can be monitored in real time via WiFi or the cloud.
Mobile phone monitoring system:
You can monitor the operating status of the equipment with your mobile phone, which is simple and convenient (optional)
Cold trap defrost system:
The hot air defrosting method has high safety performance; the defrosting speed is fast, which solves the inconvenience caused by traditional immersion defrosting.