IVD5435 MagPure Circulating DNA Maxi Kit

Facebook
X
Pinterest
Email

This Kit is designed forpurification of high quality circulating DNA (cfDNA) from 1-6ml cell-free bodyfluids (such as plasma, serum). The purified DNA is suitable for direct use indownstream applications such as PCR, real-time PCR, Biochip analysis and NGS.

Detail

Introduction

This Kit is designed forpurification of high quality circulating DNA (cfDNA) from 1-6ml cell-free bodyfluids (such as plasma, serum). The purified DNA is suitable for direct use indownstream applications such as PCR, real-time PCR, Biochip analysis and NGS.

Details

Specifications

FeaturesSpecifications
Main FunctionsIsolation circulating DNA from 1-6ml plasma, serum, body fluids
ApplicationsqPCR, NGS, etc.
Purification technologyMagnetic beads technology
Process methodManual or automatic
Sample typeSerum, plasma
Sample amount1-6ml
Elution volume≥50μl
Time per run≤60 minutes

Principle

This product is based on the purification method of high binding magnetic particles. The sample is lysed and digested under the action of lysate and protease. DNA is released into the lysate. After adding magnetic particles and binding solution, DNA will be adsorbed on the surface of magnetic particles, and impurities such as proteins will be removed without adsorption. The adsorbed particles were washed with washing solution to remove proteins and impurities, washed with ethanol to remove salts, and finally DNA was eluted by elution buffer.

Advantages

  • Economy – less than 50% of the price of Qiagen and other imported products
  • Automatic – without labour
  • High purity – OD 260 / 280 : 1.7-1.9, OD 260 / 230 :1.5-2.0

Kit Contents

ContentsIVD5435
Purification Times50
MagPure Particles F14 ml
Carrier RNA310 μg
Proteinase K240 mg
Protease Dissolve Buffer15 ml
Buffer SDS15 ml
Buffer MLK500 ml
Buffer MAW1250 ml
Buffer MW2*50 ml
Elution Buffer60 ml

Storage and Stability

Proteinase K, Carrier RNA and MagPure Particles F should be stored at 2–8°C upon arrival. However, short-term storage (up to 12 weeks) at room temperature (15–25°C) does not affect their performance.Theremaining kit components can be stored dry at room temperature (15–25°C) and are stable for at least 18 months under these conditions.The entire kit can be stored at 2–8°C, but in this case buffers should beredissolved before use. Make sure that all buffers are at room temperature when used.

Experiment Data

Other Products

NGS Library Circularization Kit (MGI Platform)

TDL5E Bench top low speed refrigerated centrifuge machine 

D3117 HiPure Tissue&Blood DNA 96 Kit