MagPure A3 utilizes Magen’s solid-phase paramagnetic bead technology for high-throughput purification of PCR amplicons. AmPure utilizes an optimized buffer to selectively bind PCR amplicons 100bp and larger to paramagnetic beads. Excess primes, nucleotides, salts and enzymes can be removed using a simple washing procedure. The resulting purified PCR product is essentially free of contaminants.
Detail
Introduction
MagPure A3 utilizes Magen’s solid-phase paramagnetic bead technology for high-throughput purification of PCR amplicons. AmPure utilizes an optimized buffer to selectively bind PCR amplicons 100bp and larger to paramagnetic beads. Excess primes, nucleotides, salts and enzymes can be removed using a simple washing procedure. The resulting purified PCR product is essentially free of contaminants.
Details
Specifications
Features
Specifications
Main Functions
Selectively recover DNA from PCR products and enzymatic reaction solution (Replace Beckmen or agencourt AmPure)
Applications
Sequencing, gene chip and qPCR, etc.
Purification technology
Magnetic beads technology
Process method
Manual (centrifugation or vacuum)
Sample type
PCR products, enzymatic reaction solution
Sample amount
Appropriate
Elution volume
≥15μl
Operation time
≤50 minutes
Principle
This product is based on the purification method of high binding magnetic particles. PCR amplicons mix with MagPure A3, 100bp and larger DNA binds to magnetic beads. Excessprimes, nucleotides, salts and enzymes can be removed using a simple washing procedure and finally DNA was eluted by Elution Buffer or Water.
Advantages
Wide application – DNA products, enzyme digestion system, PCR reaction
High recovery – suitable for 100bp-30kb fragments
High purity – effectively remove dNTP, primer, primer dimer, salt ion and other impurities
Strong applicability – manual operation or automatic workstation
Kit Contents
Contents
BXP-5
BXP-50
BXP-500
MagPure A3
5 ml
50 ml
500 ml
Storage and Stability
MagPure A3 should be stored at 2-8°C upon arrival and is stable up to 18 months under the condition. However, short-term storage (up to 12 weeks) at room temperature (15-25°C) does not affect its performance. Shake the reagent well before use. It should appear homogenous and consistent in color.DO NOT FREEZE.
The Ethanol (Liquid Ready) assay kit is a rapid (~5 min), method for the specific measurement and analysis of ethanol in wine, beverages, foodstuffs and other materials. Supplied as a “ready to use” liquid stable formulation that is suitable for manual auto-analyser and microplate formats and is simple, reliable and accurate.
Suitable for manual, auto-analyser and microplate formats.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
Magnetic bead nucleic acid purification technology uses nano or micron superparamagnetic material as the matrix, generally black ferric oxide or yellowish brown ferricoxide as the magnetic material. The surface of bead is coated with appropriate functional groups, which can adsorb nucleic acid. Magnetic beads commonly used for nucleic acids, containing carboxyl groups, hydroxyl groups, or silicon groups. Silicon-based magnetic beads are the most common, and its principle of adsorbing nucleic acid is consistent with the classical glass milk purification technology or glass fiber filter membrane purification method. Magpure particle is a kind of polydisperse fast speed silica magnetic beads. The core is ferricoxide, accounting for 50%, and the surface coating is silica, accounting for 50%. The product can be used for plasmid extraction, gel DNA recovery, product purification, genomic DNA and RNA extraction, and viral nucleic acid extraction.
Details
Specifications
Features
Specifications
Concentration
40 mg/ml
Appearance
Suspension of dark brown particles
Surface functional group
Si-OH, Silanol
Dispersibility
Monodisperse,spherical
Particle size
1.0-1.5 μm
Preservation conditions
Room Temperature, valid for up to 2 years.It is recommended to store in 2-8°C to prevent microbial growth.
Magnetic response speed
~30 seconds
Settling velocity
>3 minutes
High salt mediated binding
>2M guanidine isothiocyanate, DNA recovery up to 80%
Alcohol mediated binding
2M guanidine hydrochloride / isopropanol (30%), and the recovery of DNA / RNA was as high as 85%
PEG8000 mediated binding
The recovery of DNA/RNA was up to 85%
DNase/RNase
Not detected
DNA residue
Not detected
Recommended application
Genomic DNA extraction, RNA extraction, viral nucleic acid extraction, circulating DNA isolation
Principle
Highsalt mediated binding: in the solution containing 2-4M guanidine isothiocyanate, Magpure particles can selectively recover DNA molecules, and impurities such as protein polysaccharides are not adsorbed.
Alcohol mediated binding: in the solution containing guanidine salt and alcohol (>25%), Magpure particles can selectively recover DNA/RNA molecules, and proteins and other impurities are not adsorbed.
After biological samples are treated with digestive solution or lysis Buffer, DNA/RNA is released from cells, organelles and protein complexes (ribosomes and nucleosomes) into reagents. After Magpure particles and binding solution are added, DNA/RNA is adsorbed to the surface of Magpure particles to form DNA/RNA bead complex. Under the action of the magnetic field, the magnetic beads are separated and collected, and the impurities such as protein are removed with the waste liquid. After two or three steps of further cleaning, the DNA/RNA magnetic bead complex is resuspended in sterilized water or TE buffer, and the DNA/RNA falls off from the surface of the magnetic beads, so as to achieve the purpose of purification.
gDNA/RNA Isolation from Blood, Tissue, Plant, Swab, Spots, Stool, Soil and etc.Viral DNA/RNA IsolationAgarose Gel DNA Purification
DNA/RNA Isolation from low nucleic acid content samplesPlasmid IsolationDNA/RNA Clean Up
Circulating DNA IsolationViral Nucleic acid IsolationgDNA Isolation FFPE DNA/RNA Isolation
Plasmid extractiongel DNA recoverygenomicDNA/RNA extraction viral nucleic acid extractionCirculating DNA extraction
DNA/RNA Clean Up and concentrationDNA/RNA Isolation from low nucleic acid content samplesResearch immuno assays
The MagPure magnetic-particle technology combines the speed and efficiency of silica-based DNA purification with the convenient handling of magnetic particles. DNA binds to the silica surface of the magnetic particles in the presence of a chaotropic salt. DNA bound to the particles is then efficiently washed, considerably improving the purity of DNA. High-quality DNA is eluted. The automated purification procedure completely removes enzymes, nucleotides, and other contaminants and inhibitors. Purified DNA is suitable for direct use in downstream applications, such as sequencing and microarray analysis.
Document
Magnetic bead nucleic acid purification technology uses nano or micron superparamagnetic material as the matrix, generally black ferric oxide or yellowish brown ferricoxide as the magnetic material. The surface of bead is coated with appropriate functional groups, which can adsorb nucleic acid. Magnetic beads commonly used for nucleic acids, containing carboxyl groups, hydroxyl groups, or silicon groups. Silicon-based magnetic beads are the most common, and its principle of adsorbing nucleic acid is consistent with the classical glass milk purification technology or glass fiber filter membrane purification method. Magpure particle is a kind of polydisperse fast speed silica magnetic beads. The core is ferricoxide, accounting for 50%, and the surface coating is silica, accounting for 50%. The product can be used for plasmid extraction, gel DNA recovery, product purification, genomic DNA and RNA extraction, and viral nucleic acid extraction.
Norgen’s Total Nucleic Acid Preservation Tubes are designed for ambient preservation and transport of total nucleic acids (DNA and RNA) from samples collected using a swab, including nasal, buccal, saliva, fecal, skin, surfaces, etc. The Total Nucleic Acid Preservation Tubes contain Norgen’s Total Nucleic Acid Preservative in a liquid format. The user simply collects the specimen using a sterile nylon flocked swab (not provided), and then transfers the swab into the Total Nucleic Acid Preservative. The preservative prevents the growth of Gram-negative and Gram-positive bacteria and fungi, and also inactivates viruses allowing the resulting non-infectious samples to be handled and shipped safely. In addition, the Total Nucleic Acid Preservative eliminates the need to immediately process or freeze samples and allows the samples to be shipped to centralized testing facilities at ambient temperatures. The components of the Preservative allow DNA samples to be stored at room temperature for over 4 months and RNA samples to be stored at room temperature for over 2 months. Swab samples collected and preserved using Norgen’s Total Nucleic Acid Preservation Tubes are compatible with most commercially available DNA and RNA isolation methods. Samples stored in the tubes have been used successfully with most of Norgen Biotek’s DNA and RNA isolation kits and reagents, including Norgen’s Total RNA Purification Kit (Cat# 17200) and Norgen’s Saliva DNA Isolation Kit (Cat# RU45400). For purification of total nucleic acids please refer to the supplementary protocol provided with Norgen’s Total RNA Purification Kit (Cat#17200).
The Total Nucleic Acid Preservation Tubes can be stored at room temperature for up 1 year without any reduction in kit performance. The collect before date is indicated on the tube label and the kit box label.