A handheld 8-tube screw cap tube capper/decapper. Securely seal or unscrew an 8-cap row in just 10 seconds, or an entire rack of 96 tubes in 2 minutes.
Detail
A handheld 8-tube screw cap tube capper/decapper. Securely seal or unscrew an 8-cap row in just 10 seconds, or an entire rack of 96 tubes in 2 minutes.
About
8-Channel Handheld Capper/Decapper – Saving you Time and Effort
The 8-Channel Handheld Capper/Decapper is a versatile tool designed to increase throughput and save you time and effort. Capable of consistently capping and de-capping multiple tubes simultaneously, this innovative device ensures smooth and efficient lab operations. Its lightweight, ergonomic design reduces operator strain and seamlessly transitions from manual to automated systems, making it an indispensable addition to any laboratory.
Speed and Efficiency
With the ability to securely seal an 8-cap row in just 10 seconds or an entire rack of 96 tubes in 2 minutes, the 8-Channel Handheld Capper/Decapper significantly enhances manual processing throughput. The device guarantees consistent sealing across each tube. Its automatic column-type cap removal and capping performance streamline workflows, ensuring quick and reliable operation. This not only saves valuable time but also reduces the risk of repetitive strain injuries for lab personnel.
Ergonomic and Portable
Designed with user comfort in mind, the 8-Channel Handheld Capper/Decapper is lightweight and ergonomically crafted for effortless screw cap processing. It’s neat, compact design and low-force, dual-button cap ejection system makes it ideal for various laboratory environments. Its included storage stand ensures secure and convenient storage and when not in use.
Convenient Charging and Compatibility
The tool features magnetic contact charging, offering long battery life and fast charging times. Ready to use whenever you are, it efficiently caps, de-caps, or recaps tubes by column or row. Interchangeable cap driver cassettes allow for easy processing of different screw cap tube types and SBS rack formats.
Request a Demo or Speak to an Expert
Experience the efficiency and convenience of the 8-Channel Handheld Capper/Decapper in your lab. Visit our website to request a demo or speak to one of our experts to learn more about how this innovative tool can enhance your laboratory’s operations.
Other Products
D2110 HiPure Gel DNA Micro Kit
Product Info
Document
Product Info
Introduction
HiPure Gel Pure DNA Kit uses proprietary chemistry and HiPure technology to recover DNA fragments between 80bp-15kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing, restriction digestion, or various labeling reactions. In addition, this kit can be also used to recover DNA directly from enzymatic reactions such as PCR and enzyme digestion reactions.
Note: This kit can only recover 200mg of gel at most. If it is larger than 200mg, the column may be blocked. This column can only recover 5μg of DNA at most.
Details
Specifications
Features
Specifications
Main Functions
Recover DNA fragments >100bp from agarose gel(<0.2g), purification of DNA from PCR or enzymatic reaction solution solution
Applications
PCR, NGS, labeling, ligation and enzyme digestion, etc.
Purification method
Micro spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Agarose gel, PCR products, enzyme products
Sample amount
Agarose gel: ≤200mgDNA products: ≤300µl (≤5µg)
Recovery
100-5000bp:85%, 5-10kb:60-70%
Elution volume
≥10μl
Time per run
≤30 minutes(1-24 samples)
Liquid carrying volume per column
800µl
Binding yield of column
20µg
Principle
The HiPure system uses a simple bind-wash-elute procedure. Gel slices are dissolved in a buffer containing a pH indicator, allowing easy determination of the optimal pH for DNA binding, and the mixture is applied to the column. Nucleic acids adsorb to the silica-gel membrane in the high-salt conditions provided by the buffer. Impurities are washed away and pure DNA is eluted with a small volume of low-salt buffer provided or water, ready to use in subsequent applications.
Advantages
High recovery efficiency – up to 80% DNA recovery
Low elution volume – elution volume can be as low as 10μl
General – recover DNA fromgel or enzyme-driven reaction solutions such as PCR
Fast – isolation can be completed in 10-15 minutes by column gel method
Kit Contents
Contents
D211002
D211003
Purification Times
100 Preps
250 Preps
Buffer GDP
60 ml
125 ml
Buffer DW1
40 ml
90 ml
Buffer DW2
20 ml
50 ml
Elution Buffer
20 ml
30 ml
HiPure DNA Micro Columns
100
250
2 ml Collection Tubes
100
250
Storage and Stability
The Kit should be stored dry at room temperature (15-25°C) and are stable for at least 18 months under these conditions. If any precipitates form in the buffers, warm at 37℃ to dissolve
Document
HiPure Gel Pure DNA Kit uses proprietary chemistry and HiPure technology to recover DNA fragments between 80bp-15kbp with yields exceeding 80%. DNA is suitable for ligations, PCR, sequencing, restriction digestion, or various labeling reactions. In addition, this kit can be also used to recover DNA directly from enzymatic reactions such as PCR and enzyme digestion reactions.
Note: This kit can only recover 200mg of gel at most. If it is larger than 200mg, the column may be blocked. This column can only recover 5μg of DNA at most.
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
The series of nucleic acid columns produced by Magen Biotech are based on carefully selected imported glass fiber membranes (GF/B, GF/D, GF/F). Columns production processes such as polypropylene injection molding materials, injection molding process, and downstream membrane packing and compression rings are strictly controlled. This is to ensure that the column has extremely high adsorption capacity and long-term stability. Compared with conventional products on the market, Magen’s columns are with varieties, and binding rate will not change when stored at room temperature for 4 years.
Details
Specifications
Features
Specifications
Recommended application
gDNA medium yield preparation, total RNA medium yield preparation
Preservation conditions
Room temperature
Stability
Up to 4 years
Filter membrane
High quality glass fiber filter GF/B, 4 layers
Membrane aperture
1.0 μm
Maximum yield of alcohol mediated Binding
1 mg
Single liquid carrying capacity of column
4 ml
Minimum elution volume
500 μl
Withstand centrifugal force
3,000 – 5,000 x g
Centrifuge
Lowspeed centrifuge for 15ml centrifuge tubes, >3000 x g, swing-out Rotor, or Fixed Angle Rotor
Adsorption Mechanism
Based on the negatively charged DNA skeleton, it has a high affinity for positively charged glass fibers. In high salt and ethanol solutions, DNA/RNA binds to glass fiber and interacts with hydrophilic matrix on silica through hydrogen bond. DNA/RNA is tightly bound. All pollutants can be removed by washing solution. At high salt concentration, nucleic acids selectively bind to silica gel membrane, while other pollutants, mainly proteins, are removed by membrane washing.
Ordering information
CAT.No.
Product Name
Package
C13120
HiPure DNA Midi Column (4 x GF/B)with 15ml Collection Tubes
100/Bag
Purchase Guide
Item No.
Product Name
Membrane type/number of layers
Collection tubes
Plasmid DNA binding capacity (Physical adsorption)
Note: GF/B pore size is for 1.0μM glass fiber membrane; GF/F pore size is for 0.7μm glass fiber membrane.
Document
Magen’s HiPure columns are prepared by high quality glass fiber filter membrane as raw materials through membrane cutting, membrane release, ring release, ring pressing, gland, weighing and other processes. HiPure nucleic acid adsorption columns have the characteristics of long-term stability and high binding capacity. Experiments show that the highest binding capacity and binding efficiency of HiPure nucleic acid adsorption columns are basically unchanged when stored at room temperature for 4 years.
Isolate all sizes of circulating and exosomal RNA, including microRNA
Versatile plasma/serum input ranges
No phenol extractions
No carrier RNA
Bind and elute all RNA irrespective of size or GC content, without bias
Concentrate circulating RNA and exosomal RNA into a flexible elution volume
High quality, purified RNA is suitable for a variety of downstream applications, including Small RNA Sequencing. Find out more information on Norgen’s NGS services
Compatible with Streck Cell-Free RNA BCT® Tubes
Purification is based on spin column chromatography that uses Norgen’s proprietary resin separation matrix
These kits provide a fast, reliable and convenient method to purify and concentrate high quality, high purity and inhibitor-free cell-free circulating and exosomal RNA using a convenient spin column method. These kits can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate. Plasma samples prepared from blood collected on heparin should not be used, as heparin can significantly interfere with many downstream applications such as RT-PCR. The purified plasma/serum RNA is fully compatible with all downstream applications including PCR, qPCR, methylation-sensitive reverse transcription qPCR, reverse transcription PCR, Northern blotting, RNase protection and primer extension, expression array assays, and NGS.
Background
Plasma/Serum cell-free circulating RNA or exosomal RNA has the potential to provide biomarkers for certain cancers and disease states. Exosomes are 40 – 150 nm membrane vesicles, which are secreted by most cell types. Exosomes can be found in saliva, blood, urine, amniotic fluid and malignant ascitic fluids, among other biological fluids. Evidence has been accumulating recently that these vesicles act as cellular messengers, conveying information to distant cells and tissues within the body. These exosomes may play a functional role in mediating adaptive immune responses to infectious agents and tumours, tissue repair, neural communication and transfer of pathogenic proteins. For this reason exosomal RNAs may serve as biomarkers for various diseases including cancer. As the RNA molecules encapsulated within exosomes are protected from degradation by RNAses they can be efficiently recovered from biological fluids, such as plasma or serum.
Plasma/Serum RNA Purification Mini Kit
This kit can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate, from volumes ranging from 50 µL to 200 µL. The purified plasma/serum RNA is eluted in a flexible final volume of 10 µL to 25 µL.
Plasma/Serum RNA Purification Midi Kit
This utilizes a two column method, and can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate, from volumes ranging from 250 µL to 1.5 mL. The first column will handle the large volume input of bodily fluids that is followed by a concentration on a mini column for a final elution of 50 µL to 100 µL.
Plasma/Serum RNA Purification Maxi Kit
This kit can purify RNA from fresh or frozen serum or plasma samples prepared from blood collected on either EDTA or Citrate, from volumes ranging from 2 mL to 5 mL. The first column will handle the large volume input of bodily fluids that is followed by a concentration on a mini column for a final elution of 50 µL to 100 µL.
All sizes, including miRNA and small RNA (<200 nt)
Elution Volume
50-100 μL
Time to Complete 10 Purifications
35-40 minutes
Average Yields*
Variable depending on specimen
*Please check page 7 of the Product Insert for Average Plasma/Serum Yields and Common RNA Quantification Methods.
This kit is suitable for the isolation of RNA from fresh or frozen serum or plasma prepared from blood collected on either EDTA or Citrate. Plasma samples prepared from blood collected on heparin should not be used as heparin can significantly interfere with many downstream applications such as RT-PCR.
Storage Conditions and Product Stability All solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment. It is recommended to warm Lysis Buffer A for 20 minutes at 60°C if any salt precipitation is observed.