96-Well Universal Bar Magnetic Plate with Integrated Cushion base
Facebook
X
Pinterest
Email
Permagen’s MSPU650R is identical to the product shown above, with the exception of the added integrated cushion base which helps aid in robot and consumable labware inconsistencies for precision pipetting
Detail
Permagen’s MSPU650R is identical to the product shown above, with the exception of the added integrated cushion base which helps aid in robot and consumable labware inconsistencies for precision pipetting
Features include solid aluminum alloy construction and hard coat anodized finish for years of trouble-free use, and compatible with any magnetic beads
DNase activity in a convenient and sensitive lateral flow colormetric assay that delivers results in real time. Great for Quality Testing for DNase contamination of materials and supplies.
Attogene’s DNaseAlarm Lateral Flow test is designed for the sensitive and accurate analysis of DNAse activity in liquid samples. DNase Alarm uses a synthetic DNA substrate that attaches to the streptavidin colloidal reporter molecule (gold) using a 5’ biotin. The DNA substrate also contains a FAM molecule that enables it to be captured by the anti-FAM antibody (test line). In the absence of DNases, the DNA oligo tethers gold to the test line giving a visual test line. When DNases are present, the DNA substrate is degraded, and the gold particles can no longer be tethered to the test line thus, signal is lost. Since the cleavage of the DNA Substrate increases over time when DNase activity is present, results can be evaluated kinetically. This assay has applications for quality control testing and analysis of unit activities of DNase and DNase inhibitors. DNase’s can cause havoc in laboratories working with DNA and are important to perform routine testing.
This test can be used to rapidly and efficiently detect DNase’s in both liquid and on solid surfaces and a perfect tool for monitoring manufacturing.
Document
DNase activity in a convenient and sensitive lateral flow colormetric assay that delivers results in real time. Great for Quality Testing for DNase contamination of materials and supplies
[RP1400] ExcelRT™ Reverse Transcription Kit II, 100 RXN
Product Info
Document
Product Info
Description
ExcelRT™ Reverse Transcription Kit II is a complete, efficient and convenient kit to synthesize high quality first strand cDNA. This kit contains ExcelRT™ Reverse Transcriptase, which is able to synthesize the first strand cDNA at 37~50°C. The ExcelRT™ Reverse Transcriptase is a recombinant Moloney Murine Leukemia Virus (M-MLV) reverse transcriptase, which is designed to reduce RNase H activity and create better thermal stability. This kit also contains RNAok™ RNase Inhibitor, which is active against RNase A, RNase B, and RNase C. This product is supplied with optimized RT Buffer and Oligo (dT)/Random Primer Mix for highly efficient synthesis of short chain cDNA suitable for real-time PCR.
Features
Contains all components for reverse transcription
High yield
Thermostable, up to 50°C
Reduced RNase H ribonuclease activity
Suitable for real-time PCR
Application
Generation of first strand cDNA from total RNA or mRNA.
Suitable for generating cDNA from RNA with strong secondary structure which can be reduced at temperature up to 50°C.
Storage
-20°C for 24 months
Document
ExcelRT™ Reverse Transcription Kit II is a complete, efficient and convenient kit to synthesize high quality first strand cDNA. This kit contains ExcelRT™ Reverse Transcriptase, which is able to synthesize the first strand cDNA at 37~50°C. The ExcelRT™ Reverse Transcriptase is a recombinant Moloney Murine Leukemia Virus (M-MLV) reverse transcriptase, which is designed to reduce RNase H activity and create better thermal stability. This kit also contains RNAok™ RNase Inhibitor, which is active against RNase A, RNase B, and RNase C. This product is supplied with optimized RT Buffer and Oligo (dT)/Random Primer Mix for highly efficient synthesis of short chain cDNA suitable for real-time PCR.
Hipure Microbial RNA kit is suitable for extracting high-purity total RNA from bacterial/yeast culture medium. This kit combines high-efficiency Magzol Reagent (one-step extraction reagent) and silicagel column purification technology to complete the extraction of high-purity total RNA in only 40 minutes. The obtained RNA can be directly used in RT-PCR, Northern blot, poly-A + purification, nucleic acid protection and in vitro translation.
Details
Specifications
Features
Specifications
Main Functions
Isolation total RNA from bacteria, yeast cells
Applications
RT-PCR, Northern blot, poly-A + purification, nucleic acid protection and in vitro translation
Purification method
Mini spin column
Purification technology
Silica technology
Process method
Manual (centrifugation or vacuum)
Sample type
Bacteria, yeast cells
Sample amount
Bacteria: <10^9;Yeast cells:<2 x10^7
Elution volume
≥30μl
Time per run
≤40 minutes
Liquid carrying volume per column
800µl
Binding yield of column
100µg
Principle
Hipure silica gel column is based on glass fiber filter membrane with high binding force. Under the condition of high concentration of ionizing agent (such as guanidine hydrochloride or guanidine isothiocyanate), the filter membrane can adsorb nucleic acid through hydrogen bond and electrostatic, while protein and other impurities are not adsorbed and removed. The filter membrane adsorbed with nucleic acid is washed to remove the residual protein and salt. Finally, the nucleic acid adsorbed on the filter membrane can be washed out with low salt buffer (such as buffer TE) or water. The obtained nucleic acid has high purity and can be directly used in various downstream experiments.
Advantages
Fast – several samples can be extracted in 30 minutes
High purity – the purified RNA can be directly used in various downstream applications
High recovery – RNA can be recovered at the level of PG
Good repeatability – silica gel column purification technology can obtain ideal results every time
Broad spectrum – it can deal with various bacteria, including Gram-positive bacteria that are difficult to be lysed
Sufficient components – the kit contains carried wall breaking enzymes and glass beads
Kit Contents
Contents
R418202
R418203
Purification Times
50 Preps
250 Preps
HiPure RNA Mini Columns
50
250
2ml Collection Tubes
50
250
Glass Beads (0.1-0.6mm)
30 g
150 g
DNase I
600 μl
5 x 600 μl
DNase Buffer
6 ml
30 ml
Protease Dissolve Buffer
1.8 ml
15 ml
Buffer ATL
50 ml
200 ml
Buffer PHC
50 ml
200 ml
Buffer GXP2*
20 ml
100 ml
Buffer RW1
50 ml
250 ml
Buffer RW2*
20 ml
2 x 50 ml
RNase Free Water
10 ml
30 ml
Storage and Stability
Buffer PHC should be stored at 2–8°C upon arrival. DNase I should be stored at -20°C. However, short-term storage (DNase I up to 1 weeks, Buffer PHC up to 12 weeks) at room temperature(15–25°C) does not affect their performance. The remaining kit components can be stored at roomtemperature (15–25°C) and are stable for at least 18 months under these conditions.
Document
Hipure Microbial RNA kit is suitable for extracting high-purity total RNA from bacterial/yeast culture medium. This kit combines high-efficiency Magzol Reagent (one-step extraction reagent) and silicagel column purification technology to complete the extraction of high-purity total RNA in only 40 minutes. The obtained RNA can be directly used in RT-PCR, Northern blot, poly-A + purification, nucleic acid protection and in vitro translation.