The Permagen Post magnet low elution plate was designed for use in manual or automation applications where volumes as low as 5 µL are required. The post magnets will create bead pellets to one quadrant of the well making aspiration easier and accidental bead disruption less likely
Detail
The Permagen Post magnet low elution plate was designed for use in manual or automation applications where volumes as low as 5 µL are required. The post magnets will create bead pellets to one quadrant of the well making aspiration easier and accidental bead disruption less likely
SBS SLAS Footprint (127.75mm x 85.50mm) to fit into any automated liquid handling robot
Features include solid aluminum alloy construction and hard coat anodized finish for years of trouble-free use, and compatible with any magnetic beads
TGL20 Table Top High Speed Refrigerated Centrifuge
Product Info
Document
Product Info
TGL20 Technical Parameters
Max Speed
21000r/min
Max Volume
6×100ml
Timer
1~99h59min
Dimension
570×620×380mm
Speed Accuracy
±20r/min
Max RCF
30910×g
Noise
≤58dBA
Net Weight
84KG
Power supply
AC 220V, 50HZ 10A
Temperature Range
-20℃~40℃
Temperature Accuracy
±1℃
Matched Rotors for TGL20
Order no
Rotor
Max Speed(r/min)
Volume(ml)
Max RCF(*g)
G20-1
Fixed Rotor
16000
4×8PCR
15760
G20-2
Fixed Rotor
15000
6×8PCR
21420
G20-3
Fixed Rotor
16000
8×8PCR
17480
G20-4
Fixed Rotor
15000
12×8PCR
22930
G20-5
Fixed Rotor
21000
12×1.5/2ml
30910
G20-6
Fixed Rotor
15000
40×0.5ml
22920
G20-7
Fixed Rotor
17000
24×1.5/2ml
26460
G20-8
Fixed Rotor
13500
30×1.5/2ml
19340
G20-9
Fixed Rotor
13000
48×1.5/2ml
17930
G20-10
Fixed Rotor
16000
16×5ml
22020
G20-11
Fixed Rotor
16000
6×10ml
21500
G20-12
Fixed Rotor
15000
12×10ml
22680
G20-13
Fixed Rotor
16000
12×7ml
21380
G20-14
Fixed Rotor
13000
16×10ml
19490
G20-15
Fixed Rotor
10000
12×15ml
11840
G20-16
Fixed Rotor
13000
8×15ml(falcon)
17790
G20-17
Fixed Rotor
5000
24×15ml
3500
G20-18
Fixed Rotor
15000
8×20ml
22680
G20-19
Fixed Rotor
5000
30×15ml
3830
G20-20
Fixed Rotor
14000
6×30ml
19060
G20-21
Fixed Rotor
13000
6×50ml(falcon)
18840
G20-22
Fixed Rotor
13000
6×50ml(round)
18730
G20-23
Fixed Rotor
13000
4×85ml
18940
G20-24
Fixed Rotor
12000
6×70ml
15570
G20-25
Fixed Rotor
12000
4×100ml
14850
G20-26
Fixed Rotor
12000
6×100ml
16390
G20-27
Fixed Rotor
12000
24 pieces capillary vessel
15800
G20-28
Fixed Rotor
18000
30×0.5ml
26660
G20-29
Swing Rotor
13000
4×5ml
14960
G20-30
Vertical Rotor
16000
16×5ml
16540
G20-31
Vertical Rotor
14000
8×30ml
16450
G20-32
Microplate Rotor
4000
2×3×48(well)
2300
Document
Features:
1. Digital display indicates the speed,time,temperature and RCF.
2. Brushless DC motor in great torque, free maintenance,no powder pollution.quick in speed up and down.
3. There are many kinds of rotors for choice.
4. Automatically electric lid lock,super speed,over temperature protection and imbalance protection.
5. The centrifuge body is made of high-quality steel,safe and reliable.
High Sensitivity RNA Amplification With Improved Detection Isothermal Kit
Product Info
Document
Product Info
Product Description
High Sensitivity RNA Amplification With Improved Detection Isothermal Kit
Product Detail
Applicable equipment:
It is recommended to use the Isothermal fluorescence detector developed by Amp-future, which is also suitable for fluorescence quantitative PCR apparatus with market known brands.
Kit Storage and term of Validity
Storage term: stored at ≤-20℃,keep away from light, avoid heavy weight and repeated freezing and thawing.
Term of Validity: 14 months
Isothermal nucleic acid Principle Summary
This kit is based on a rapid nucleic acid amplification technology at room temperature and constant temperature: at room temperature and constant temperature (generally 39℃~42℃), with the help of auxiliary proteins and single-strand binding proteins,the recombinase and primers form a complex;Source search and combine the target homology domain, at this time,a D-loop region is formed at the homology position and strand exchange begins;along with the dissociation of the recombinase from the complex,the polymerase also binds to the 3′ end of the primer and begins chain extension. At the same time, relying on the function of exonuclease, adding specific molecular probes designed according to the template, and using fluorescence monitoring equipment can realize real-time monitoring of the amplification process of the target fragment.
Isothermal nucleic acid Product Features
1/ High sensitivity and specificity, short reaction time.
2/ The reagent form is freeze-dried, stable and easy to operate.
Technical Parameters:
Parameters
Details
Product Name
DNA Isothermal Amplification Kit EXO
Manufacturer
Amp-future
Storage Temperature
-20°C
Kit Components
Enzymes, Buffers ,Reagents
Packaging
48 Tests/box
Detection Limit
500-1000copies/µL
Shipping
ICE
Test Time
5-20mins
Isothermal nucleic acid Applications
Suitable for DNA isothermal rapid amplification kit(fluorescent type)
Primer: Require pair of nucleotide primers with the length of 25-35 bp.
Fluorescent Probe:Require the suitable length is 46-52nt.
DNA fluorescent kit reaction temperature is 39 to 42℃ and time is 5-20 minutes.
Notes
1/ Please avoid nucleic acid contamination and set blank control during reaction due to the high sensitivity of the kit.
2/ Please take out the required quantity of MIRA reaction units for the experiment, and put the rest under storage conditions when performing the experiment.
Document
It is recommended to use the Isothermal fluorescence detector developed by Amp-future, which is also suitable for fluorescence quantitative PCR apparatus with market known brands.
1. The instantaneous centrifugal function rises to the maximum speed for about 6 seconds, allowing for rapid detachment of hanging droplets from the wall;
2. Faster acceleration and deceleration rate, required to complete the experiment in a shorter time;
3. Door cover protection, overspeed and imbalance detection system, capable of real-time monitoring of the centrifugal process, ensuring the safe operation of the instrument; When the operation ends, an error occurs, or an imbalance occurs, the sound signal prompts, and the operation stops at the same time. The LCD displays the result code
Host Parameters
Product model
Mini-3
Input power supply
DC24V/2.75A
Input power
55W
Motor/Drive Method
DC24V brushless DC variable frequency motor
Display method
High brightness LCD screen
Effective centrifugal time
1-99min.1-59sec
speed
300~3000±15rpm
Speed step increase
10rpm
Maximum capacity
2 *96 well PCR plates/ELISA plates
MAX. RCF
608 xg
Misoperation/alarm failure
Sound prompt+display code
weight
3.9Kg
Noise
60dB (A)
Fastest acceleration time
<6s
Fastest deceleration time
<5s
Permissible ambient temperature/relative temperature
+5-40°C/80%
Document
The micro porous plate centrifuge adopts international advanced design concepts and manufacturing technology, with a smooth and beautiful appearance, compact and stable structure, adhering to the advantages of high universality and easy operation. It also has the functional characteristics of “smooth start” and “smooth braking”; This micro porous plate centrifuge is very suitable for 96 or 384 well and small capacity micro porous plates, as well as various standard PCR micro porous plates with or without skirts .