Permagen’s 16 x 1.5 mL Microfuge Tube Magnetic rack is designed for magnetic bead separations from up to 16 tubes
Detail
Permagen’s 16 x 1.5 mL Microfuge Tube Magnetic rack is designed for magnetic bead separations from up to 16 tubes
Contains the strongest magnets out of all of our Microfuge racks
Tubes are pushed 14mm between centers allowing the use of an 8-channel, adjustable head pipette. 8 tubes per side also make for easy transition to and from microplates
Accommodates many common 1.5 mL Microcentrifuge and some 2.0 mL tubes
Tubes are angled and beads will be pulled to back wall allowing easy aspiration and tip tracking down the front wall of the tubes without disturbing bead pellet
Nucleic acid testing (NAT) is the method of choice for detection and quantification of a wide range of micro organisms. Primerdesign manufactures and supplies high quality quantitative real-time PCR kits for the detection and simultaneous quantification of numerous significant pathogens . A copy number standard curve is provided for quantification and an the internal extraction template (DNA or RNA), controls for the quality of the nucleic acid extraction and eliminates false negative results.
The kit is designed with the broadest possible detection profile to ensure that all clinically relevant strains and subtypes are detected. Target sequences are selected by working with data from key opinion leaders in the field. Multiple sequence alignments and unprecedented real-time PCR expertise in design and validation ensure the best possible kit.
Details of the target and priming specificity are included in the individual handbooks above.
Packaged, optimised and ready to use. Expect Better Data.
Document
Exceptional value for money Rapid detection of all clinically relevant subtypes Positive copy number standard curve for quantification Highly specific detection profile High priming efficiency Broad dynamic detection range (>6 logs) Sensitive to < 100 copies of target
Accurate controls to confirm findings
This product is suitable for rapid extraction of DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
Details
Specifications
Features
Specifications
Main Functions
Isolation total DNA from 1-100ul blood, FFPE, tissue and other samples
Applications
Second generation sequencing, PCR, real timePCR, etc.
Purification method
Monodisperse magnetic beads
Purification technology
Magnetic beads technology
Process method
Manual or automatic
Sample type
Anticoagulant blood, concentrated blood, buffy coat, lymphocytes and cultured cells
Sample amount
Body fluid : 10 – 200μl, Tissue : ≤10mg
Yield
10ng – 15μg
Elution volume
80 -100μl
Time per run
Principle
This product is based on the purification method of high binding magnetic particles. The sample is lysed and digested under the action of lysate and Protease. DNA is released into the lysate. After adding magnetic particles and binding solution, DNA will be adsorbed on the surface of magnetic particles, and impurities such as proteins will be removed without adsorption. The adsorbed particles were washed with washing solution to remove proteins and impurities, washed with ethanol to remove salts, and finally DNA was eluted by Elution Buffer.
Advantages
High binding force – suitable for handling DNA rich samples, such as whole blood, buffy coat, concentrated blood, etc.
High purity – carboxyl magnetic beads with weak surface adsorption, getting higher purity
General – can be used for various clinical samples
Kit Contents
Contents
IVD3101
Purification Times
200
MagBind Particles
4.5 ml
Proteinase K
90 mg
Protease Dissolve Buffer
10 ml
Buffer ATL
60 ml
Buffer AL
60 ml
Buffer BD*
20 ml
Buffer BXW1*
110 ml
Elution Buffer
30 ml
Storage and Stability
Proteinase K, MagBind Particles should be stored at 2–8°C upon arrival. However, short-termstorage (up to 18 weeks) at room temperature (15–25°C) does not affect their performance. The remainingkit components can be stored dry at room temperature (15–25°C) and are stable for at least 18 months under these conditions.
Document
This product is suitable for rapid extraction of DNA from tissue, cells, blood, saliva, swabs, blood spots, semen and other clinical samples. DNA can be used directly for PCR, quantitative PCR, Southern Blot, test of virus DNA and so on.
Preferred by most scientists, the ring magnet plate is a versatile product that can be used manually or in automated liquid handlers when separating beads into rings is essential.
Available in three magnet strengths like our U500 above
Features include solid aluminum alloy construction and hard coat anodized finish for years of trouble-free use, and compatible with any magnetic beads
Ideal magnet plate for those wishing to replace Beckman® PN: A32782. (50% Cost Savings*) Features all the same dimensions and even the same magnets. Does not include the spring base but it is the same height. Perfect for those using robots that do not require springs.