The Glycerol test kit is a simple, reliable, rapid and accurate method for the measurement and analysis of Glycerol in beverages, foodstuffs and other materials.
Detail
K-GCROL
SKU: 700004292
70 assays (manual) / 700 assays (microplate)
Content:
70 assays (manual) / 700 assays (microplate)
Shipping Temperature:
Ambient
Storage Temperature:
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
Glycerol
Assay Format:
Spectrophotometer, Microplate
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Decrease
Linear Range:
0.8 to 35 µg of glycerol per assay
Limit of Detection:
0.34 mg/L
Reaction Time (min):
~ 5 min
Application examples:
Wine (and grape juice), beer, spirits, vinegar, marzipan, fruit juices, soft drinks, toothpaste, honey, tobacco, paper (and cardboard), cosmetics, pharmaceuticals, soap and other materials (e.g. biological cultures, samples, etc.).
Method recognition:
Methods based on this principle have been accepted by OIV and MEBAK
The Glycerol test kit is a simple, reliable, rapid and accurate method for the measurement and analysis of Glycerol in beverages, foodstuffs and other materials.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
Mega-Calc™ software tool is available from our website for hassle-free raw data processing
Standard included
Suitable for manual and microplate formats
Extended cofactors stability
Other Products
Streptococcus uberis TaqMan PCR Detection Kits
Product Info
Document
Product Info
Overview
Detection kits for Streptococcus uberis
Available in TaqMan format for analysis
Mastitis is the single most costly disease of dairy cattle resulting in the reduction of milk yield and quality. The inflammation of the utter is mainly caused by infection of various bacteria. Streptococcus uberis is a gram-positive bacterium that is known worldwide as an environmental pathogen responsible for a high proportion of cases of mastitis in lactating cows and is also the predominant organism isolated from mammary glands during the non-lactating period. Often it is resistant to treatment and causes persistent high somatic cell counts without clinical mastitis.
Storage Conditions and Product Stability All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival.
The Kit is designed for purification of total RNA, including miRNA and other small RNA molecules (18nt), from cultured cells and various animal and human tissues, including difficult-to-lyse tissues samples. Alternatively, a miRNA-enriched fraction and a total RNA (>200nt) fraction can be purified separately. This Kit combines phenol/guanidine-based lysis of samples and silica membrane–based purification of total RNA. MagZol Reagent, included in the kits, is a monophasic solution of phenol and guanidine thiocyanate, designed to facilitate lysis of tissues, to inhibit RNases, and also to remove most of the cellular DNA and proteins from the lysate by organic extraction.
Details
Specifications
Features
Specifications
Main Functions
Isolation miRNA and other small RNA molecules(18nt), from cultured cells and various animal and human tissues, using MagZol reagent and column
Applications
RT-PCR, Northern Blot, poly A+purification, nucleic acid protection and in vitro translation
Hipure silica gel column is based on glass fiber filter membrane with high binding force. Under the condition of high concentration of ionizing agent (such asguanidine hydrochloride or guanidine isothiocyanate), the filter membrane can adsorb nucleic acid through hydrogen bond and electrostatic, while protein andother impurities are not adsorbed and removed. The filter membrane adsorbed with nucleic acid is washed to remove the residual protein and salt. Finally, the nucleic acid adsorbed on the filter membrane can be washed out with low salt buffer (such as buffer TE) or water. The obtained nucleic acid has high purity and can be directly used in various downstream experiments.
This kit combines acid/guanidine (MagZol) extraction technology with glass fiber filter membrane purification, which can improve the extraction effect of complex samples and samples with low RNA content. After the sample is treated with MagZol reagent and chloroform, the supernatant is added with ethanol to provide appropriate binding conditions, then transferred to the purification column and centrifuged. Macromolecular RNA can be efficiently bound to the membrane. Collect the filtrate containing small RNA, add more ethanol to adjust the binding capacity of small RNA, the pollutants can be efficiently washed away by second cleaning. Finally, the purified RNA was eluted by RNase free water.
Advantages
High quality – one step RNA extraction reagent combined with silica gel column can obtain the highest concentration
Fast – several samples can be extracted in 40 minutes
High applicability – samples including animals, plants, bacteria, cells, etc.
High concentration – efficiently remove macromolecular RNA, enrich small RNA and improve sensitivity
Kit Contents
Contents
R431002
R431003
Purification Times
50 Preps
250 Preps
HiPure RNA Mini Columns
100
2 x 250
2ml Collection Tubes
100
2 x 250
MagZol Reagent
60 ml
270 ml
Buffer RWC
20 ml
80 ml
Buffer RW2*
20 ml
2 x 50 ml
RNase Free Water
10 ml
30 ml
Storage and Stability
MagZol Reagent should be stored at 2-8°C upon arrival. However, short-term storage (up to 24 weeks) at room temperature (15-25°C) does not affect its performance. The remaining kit components can be stored at room temperature (15-25°C) and are stable for at least 18 months under these conditions.
Document
The Kit is designed for purification of total RNA, including miRNA and other small RNA molecules (18nt), from cultured cells and various animal and human tissues, including difficult-to-lyse tissues samples. Alternatively, a miRNA-enriched fraction and a total RNA (>200nt) fraction can be purified separately. This Kit combines phenol/guanidine-based lysis of samples and silica membrane–based purification of total RNA. MagZol Reagent, included in the kits, is a monophasic solution of phenol and guanidine thiocyanate, designed to facilitate lysis of tissues, to inhibit RNases, and also to remove most of the cellular DNA and proteins from the lysate by organic extraction.
[RQ2200] ExcelRT™ One-Step RT-qPCR Kit (TaqMan, no ROX), 200 RXN
Product Info
Document
Product Info
Description
The ExcelRT™ One-Step RT-qPCR kit (TaqMan, no ROX) is designed for reverse transcription and quantitative real-time analysis of a specific target RNA by one-step reaction. The ExcelRT™ One-Step RT-qPCR kit (TaqMan, no ROX), consisting of One-Step RT Enzyme Mix and 2X One-Step Master Mix, is a convenient kit designed for highly efficient cDNA synthesis and highly specific real-time PCR in a single tube. The One-Step RT Enzyme Mix contains a thermostable ExcelRT™ Reverse Transcriptase and a RNAok™ RNase inhibitor. Consequently, One-Step RT Enzyme Mix can reverse transcribe RNA to cDNA at a wide temperature range from 42 to 60°C and active against RNase A, RNase B and RNase C. By containing specialized hot-start Taq DNA polymerase, which greatly reduce primer-dimer formation and can be activated within 2 minutes, the 2X One-Step Master Mix features high specificity and is suitable for fast cycle program.
Features
Reverse transcription at wide temperature range (42-60°C)
High specificity
Suitable for fast cycle program
With no ROX reference dye
Storage
Aliquot to avoid multiple freeze-thaw cycles (stable within 30 freeze-thaw cycles)
Protect from light
-20°C for 12 months
Document
The ExcelRT™ One-Step RT-qPCR kit (TaqMan, no ROX) is designed for reverse transcription and quantitative real-time analysis of a specific target RNA by one-step reaction. The ExcelRT™ One-Step RT-qPCR kit (TaqMan, no ROX), consisting of One-Step RT Enzyme Mix and 2X One-Step Master Mix, is a convenient kit designed for highly efficient cDNA synthesis and highly specific real-time PCR in a single tube. The One-Step RT Enzyme Mix contains a thermostable ExcelRT™ Reverse Transcriptase and a RNAok™ RNase inhibitor. Consequently, One-Step RT Enzyme Mix can reverse transcribe RNA to cDNA at a wide temperature range from 42 to 60°C and active against RNase A, RNase B and RNase C. By containing specialized hot-start Taq DNA polymerase, which greatly reduce primer-dimer formation and can be activated within 2 minutes, the 2X One-Step Master Mix features high specificity and is suitable for fast cycle program.