The Lactulose Assay Kit is suitable for the specific, rapid and sensitive measurement and analysis of lactulose in milk and milk-based samples. Reagents included in this kit may also be prepared for use in the procedure described by ISO Method 11285:2004.
Detail
Lactulose Assay Kit
Content:
50 assays per kit
Shipping Temperature:
Ambient
Storage Temperature:
Short term stability: 2-8oC, Long term stability: See individual component labels
Stability:
> 2 years under recommended storage conditions
Analyte:
Lactulose
Assay Format:
Spectrophotometer
Detection Method:
Absorbance
Wavelength (nm):
340
Signal Response:
Increase
Linear Range:
0.65 to 65 µg of lactulose per “Enzymatic Determination Reaction
Limit of Detection:
4.8 mg/L
Reaction Time (min):
~ 120 min
Application examples:
Milk, dairy products and foods containing milk.
Method recognition:
Novel method
The Lactulose Assay Kit is suitable for the specific, rapid and sensitive measurement and analysis of lactulose in milk and milk-based samples. Reagents included in this kit may also be prepared for use in the procedure described by ISO Method 11285:2004.
The CellG3 assay reagent for the measurement of endo-cellulase (endo-1,4-β-glucanase) contains two components; 1) 4,6-O-benzylidene-2-chloro-4-nitrophenyl-β-D-cellotrioside (BCNPG3) and 2) thermostable β-glucosidase. The benzylidene blocking group prevents any hydrolytic action by the β-glucosidase on BCNPG3. Incubation with an endo-cellulase generates a non-blocked colourimetric oligosaccharide that is rapidly hydrolysed by the ancillary β-glucosidase. The rate of formation of 2-chloro-4-nitrophenol is therefore directly related to the hydrolysis of BCNPG3 by the endo-cellulase. The reaction is terminated and the phenolate colour is developed on addition of Tris buffer solution (pH 9.0).
Please note that a new assay kit (K-CellG5) is now available for the measurement of endo-cellulase. The CellG5 reagent contains a cellopentaose core and exhibits vastly improved sensitivity for some cellulases. In addition, the exchange of the benzylidene blocking group in CellG3 for 3-keto-butylidene in CellG5 improves the substrate’s water solubility significantly, allowing for a reduction in the concentration of DMSO required in the assay. As DMSO is known to inhibit certain cellulases, this is another benefit in using CellG5. Megazyme now recommends the use of K-CellG5 for all assays for the measurement of endo-cellulase.
The CellG3 assay reagent for the measurement of endo-cellulase (endo-1,4-β-glucanase) contains two components;
1) 4,6-O-benzylidene-2-chloro-4-nitrophenyl-β-D-cellotrioside (BCNPG3) and 2) thermostable β-glucosidase. The benzylidene blocking group prevents any hydrolytic action by the β-glucosidase on BCNPG3. Incubation with an endo-cellulase generates a non-blocked colourimetric oligosaccharide that is rapidly hydrolysed by the ancillary β-glucosidase. The rate of formation of 2-chloro-4-nitrophenol is therefore directly related to the hydrolysis of BCNPG3 by the endo-cellulase. The reaction is terminated and the phenolate colour is developed on addition of Tris buffer solution (pH 9.0).
Fentanyl (FYL) Detection Kit (Rapid Lab) is a lateral flow chromatographic immunoassay for the qualitative detection of Fentanyl/Norfentanyl in liquid and powder substances at the cut-off concentration of 200 ng/mL.
It is specific for Fentanyl screening with no significant cross reactivity to other opiates, such as Morphine and Heroin.
Interpretation of test results are: positive (one line), negative (two lines), invalid (no lines or no control line).
• Sample: Liquid / Powder
• Format: Cassette
• Sensitivity: 200 ng/mL
• Specificity: Fentanyl
• Accuracy: > 98%
• Time-to-Result: 10 minutes
• Storage Condition: 2-30°C/36-86°F
• Test Principle: Lateral Flow Immunoassay
For professional institutions use only, not for self-testing.
genesig® kits are sold for research use only and are not licensed for diagnostic procedures.
Document
Exceptional value for money
Rapid detection of 2019-nCoV
Positive copy number standard curve for quantification
Highly specific detection profile
High priming efficiency
Broad dynamic detection range (>6 logs)
Sensitive to < 100 copies of target
Accurate controls to confirm findings