Real-time fluorescent DNA amplification made possible with a TwistAmp® exo kit. Recommended for users who want to combine TwistDx’s RPA amplification technology with the use of TwistDx’s proprietary fluorescent TwistAmp® exo probe in a homogenous format. The user need only supply primers, probe, and template. See manual for more information. Click to order oligonucleotides.
Detail
Real-time fluorescent DNA amplification made possible with a TwistAmp® exo kit. Recommended for users who want to combine TwistDx’s RPA amplification technology with the use of TwistDx’s proprietary fluorescent TwistAmp® exo probe in a homogenous format. The user need only supply primers, probe, and template. See manual for more information. Click to order oligonucleotides.
Other Products
Opentrons Flex Gripper
Product Info
Document
Product Info
The Opentrons Flex Gripper GEN1 attaches to the gantry and is capable of moving labware across the deck and on or off modules such as the Magnetic Block or Thermocycler. It can also access the additional slots to the side of the main deck to replenish tips or labware. The gripper can be used with any pipette configuration.
Included with the gripper is a calibration pin that enables automatic calibration to ensure positional accuracy. Currently, the gripper is optimized for use with the following labware items:
– NEST 2 mL 96 Deep Well Plate, V bottom – Opentrons Tough 0.2 mL 96-Well PCR Plate, Full Skirt – NEST 96 Well Plate Flat – All Opentrons Flex tip racks
Document
The Opentrons Flex Gripper GEN1 attaches to the gantry and is capable of moving labware across the deck and on or off modules such as the Magnetic Block or Thermocycler. It can also access the additional slots to the side of the main deck to replenish tips or labware. The gripper can be used with any pipette configuration.
Included with the gripper is a calibration pin that enables automatic calibration to ensure positional accuracy. Currently, the gripper is optimized for use with the following labware items:
– NEST 2 mL 96 Deep Well Plate, V bottom
– Opentrons Tough 0.2 mL 96-Well PCR Plate, Full Skirt
– NEST 96 Well Plate Flat
– All Opentrons Flex tip racks
MutS Homolog 6 (MSH6) is a protein involved in the mismatch repair pathway. This protein is commonly associated with hereditary non-polyposis colorectal cancer, and mutations in this gene are correlated with the development of sporadic colorectal carcinoma. Studies have shown that mutations in MSH6, when co-indicated with mutations in MSH1 and MSH2, contribute to the development of sporadic colorectal carcinoma. Use of Anti-MSH2 is optimized when paired with MSH6, MLH1, and PMS2 in an IHC panel.
Cerillo’s Stratus Plate Reader is a third party module that can be placed next to or inside the OT-2 or Opentrons Flex for post experimental analysis. The worktable adapter will allow you to utuilize the OT-2 or Opentrons Flex to prepare the samples directly into the plate reader positions on the worktable.
This small portable device is primarily for microbial growth curve analysis. The Stratus is compatible with Cerillo’s Canopy wireless device that allows real time visualization, control, and analytics. This product is compatible with reading 600nm wavelengths.
Document
Cerillo’s Stratus Plate Reader is a third party module that can be placed next to or inside the OT-2 or Opentrons Flex for post experimental analysis. The worktable adapter will allow you to utuilize the OT-2 or Opentrons Flex to prepare the samples directly into the plate reader positions on the worktable.
This small portable device is primarily for microbial growth curve analysis. The Stratus is compatible with Cerillo’s Canopy wireless device that allows real time visualization, control, and analytics. This product is compatible with reading 600nm wavelengths.