The TL 24 series of biological Microscope
TL 24 series biological microscope is equipped with 195 achromatic objective and large field eyepiece, with the characteristics of beautiful appearance, clear imaging, broad vision, convenient operation and so on, etc. It can be widely used in biology, medicine, industry, agriculture and other fields, and is an ideal instrument for medical, teaching, scientific research and other units
Details of TL24 series biological microscope
* Optical system: equipped with limited far flat field optical system, complete machine mildew prevention design and large field eyepiece, with beautiful appearance, clear imaging, broad vision, convenient operation and other characteristics, can be widely used in biology, medicine, industry, agriculture and other fields, is the ideal instrument for medical, teaching, scientific research and other units
* Observation head device: the cylinder can rotate 360 degrees, the displacement of the center of the mirror is 0.06mm; 30 tilting; the hinge double observation (the left and right systems are 2.0% different; the lens end position is 0.1mm at zero vision) and the third party connection port, pupil distance adjustment range of 55-75mm, fixed observation tube head is internal hexagon screw or select portable screw.
* Eyepiece configuration: random eyepiece WF10X / 18mm; the magnification accuracy of eyepiece shall not exceed ± 2%. There is a card slot on the eyepiece tube to lock and position the eyepiece to prevent falling. Binocular vision is adjustable, making binocular observation easier;
* Objective: Broadband coated ED-N195 pure copper achromatic objective; objective magnification accuracy not exceeding ± 5%; 4X, 10X, 40X (spring), 100X (spring, oil); objective error 10-40 Afocal 0.06mm; 40-100 Afocal 0.03mm
* Loading platform: triangular rail XY composite mechanical moving loading platform; 0.005 lateral to 5N horizontal force, corrosion resistance and wear resistance. Rectangular, size 110X120mm, stroke 7030mm, minimum read value 0.1 mm.
Specification
Specification configuration | TL24A | Binocular observation head, 45° tilt, 360 degrees can be rotated, pupil distance can be adjusted, adjustment range 50-75mm |
TL24B | Three-eye observation head, 45° tilt, 360 degrees can be rotated, pupil distance can be adjusted, adjustment range 50-75mm. | |
TL24M | Three-eye viewing head, equipped with 5 million pixel imaging system CMOS camera | |
TL24P | Three-eye viewing head, equipped with 10.1 inch integrated flat panel display | |
Eyepiece | Wide-angle eyepiece WF10X,field of view 18mm,optional WF16X,WF25X | |
Converter | Quadruple Revolving Converter | |
0bjective | 195mm achromatic objective,4X,10X,40X,100X(oil) | |
Condenser | ABBE N.A.1.25Condenser with Iris Diaphragm &Filter | |
Stage | Double Layer Mechanical Stage,Size110mmx120mm,Moving Range :70mmx30mm | |
Focusing | Crude motion, micromotion and coaxial focal adjustment system with a minimum focal range of 0.02mm Coarse and Fine Focusing | |
Light source | 1W LED,with Rechargeable Battery,Type C USB cable | |
Attachments | Dust bag,Type C power cord |
TL 24 series biological microscope is equipped with 195 achromatic objective and large field eyepiece, with the characteristics of beautiful appearance, clear imaging, broad vision, convenient operation and so on, etc. It can be widely used in biology, medicine, industry, agriculture and other fields, and is an ideal instrument for medical, teaching, scientific research and other units
Place of Origin: Guangdong, China
Warranty: 2 years
Customized support: OEM
Brand Name: HKM
Model Number: CRM011
Reagent grade: Biochemical Reagent
Form: Powder
Color: Light yellow
Type: Shigella Agar
1000mL
E. coli O157:H7 is a rod-shaped, gram negative bacterium. It is an enterohemorrhagic strain of the common E. coli bacterium and infection by the O157:H7 strain is commonly associated with hemorrhagic colitis. E. coli O157:H7 is recognized by its somatic (cell wall) antigen (O157) and its flagella antigen (H7). In addition, E. coli O157:H7 is known to produce Shiga-like toxins, which cause severe symptoms. While most patients can recover from the infection, up to 15% of the patients may develop hemolytic uremic syndrome, a type of kidney failure that could be fatal. Infection of E. coli O157:H7 usually results from consumption of poorly prepared food including undercooked meat (particularly ground beef), untreated water or raw unpasteurized milk.
E.coli O157:H7 TaqMan PCR Kit, 100 reactions
E.coli O157:H7 TaqMan PCR Probe/Primer Set and Controls, 100 reactions
For research use only and NOT intended for in vitro diagnostics.
Figure 1 / 5
Click for expanded view
Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component | Cat. TM41350 (100 preps) | Cat. TM41310 (100 preps) |
---|---|---|
MDx TaqMan 2X PCR Master Mix | 2 x 700 μL | – |
E. coli O157:H7 Primer & Probe Mix | 280 μL | 280 μL |
E. coli O157:H7 Positive Control | 150 μL | 150 μL |
Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL |
Product Insert | 1 | 1 |
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio
Privacy Policy | Terms of Use | Site Map