Laboratory Large Capacity Freezer Dryer/ Lyophilizer SF7009,SF9009,SF7012,SF9012
Facebook
X
Pinterest
Email
Model:
SF7009,SF9009,SF7012,SF9012
Brand:
Yingtai
Detail
Techinical parameter
ItemNo
SF7009
SF9009
SF7012
SF9012
Ice condenser capacity
9kg
12kg
Ice condenser temperature
-70 C°
90℃
-70 C°
-90℃
Cold trap volume
15L
20L
Freeze dried chamber
High permeability organic glass/multi manifold external valve/stainless steel chamber
Sample shelf
●φ260mm/485mm.Single layer area 0.055m²/0.185m².3-10 layers/optional ● Electric heating/manual capping/optional
Vacuum pump
Extreme vacuum 5*10*mbar with a pumping capacity of 8m³/h optional pump of various types
Oil mist filter
Standard configuration
Vacuum pump connection pipe
Single forming stainless steel flexible pipe DN16 ISO-KF L-1.2m
Anti-corrosive treatment
Cold trap,condensing coil/all equipped with PTFE anti-corrosion treatment as standard. Freeze-drying organic solvents
External valve
1-48 ports/optiona
Eutectic point judgment
Support/Optional
Data export analysis
Support/Optional
Power
0.9kw
1.5kw
1kw
1.6KW
Size
525*570*1080mm
Other Products
Human Papillomavirus (HPV) 6/16 TaqMan PCR Detection Kits
Product Info
Document
Product Info
Overview
Detection kits for the HPV 6/16
Available in TaqMan format for analysis
More than 70 types of human papillomavirus (HPV) have been identified, and are generally classified as high-risk or low-risk depending on their relationship or lack of relationship with cancer and high-grade cervical intraepithelial neoplasia (CIN 2-3). HPV viruses are predominantly sexually transmitted and high-risk HPV types are a major risk factor for development of cervical cancer. HPV 16 has been considered as a high-risk cancer associated HPV type. The low-risk HPV type 6 has been associated with the presence of genital warts. There are many other low-risk HPV types that are not associated with genital warts or cervical cancer. Until now, HPV cannot be cultured in vitro, and immunological tests are inadequate to determine the presence of HPV cervical infection. On the other hand, biopsies can be analyzed by nucleic acid hybridization to directly detect the presence of HPV DNA.
HPV 6/16 TaqMan PCR Kit, 100 reactions
Ready to use format, including Master Mix for the target and PCR control to monitor for PCR inhibition and validate the quality
Specific Primer and Probe mix for the pathogen/virus/viroid of interest
Primer and Probe mix
Positive and negative control to confirm the integrity of the kit reagents
HPV 6/16 TaqMan PCR Probe/Primer Set and Controls, 100 reactions
Specific Primer/Probe mix and Positive Control for the pathogen/virus/viroid of interest
Nuclease-free water
Can be used together with Norgen’s PCR Master Mix (#28007) or customer supplied master mix
For research use only and NOT intended for in vitro diagnostics.
Storage Conditions and Product Stability All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component
TaqMan Probe Cat. TM42050 (100 preps)
TaqMan Probe/Primer and Control Set Cat. TM42010 (100 preps)
The Opentrons Temperature Module, compatible with both the OT-2 and Flex Robots, is a fully automated thermoelectric module and integrated for use with the Opentrons platform. It is used to achieve temperature changes ranging from 4 to 95°C for various applications.
The Temperature Module GEN2 is compatible with the new Opentrons Flex Robot when paired with the Flex Temperature Caddy and Calibration Adapter. The caddy sits below the deck to enable below-deck cable routing and labware placed on modules remain closer to the deck surface. The calibration adapter is used to calibrate the location of the module. If you choose to include the Opentrons Flex Caddy and Calibration Adapter, your order will ship in 20 business days.
Document
The Opentrons Temperature Module, compatible with both the OT-2 and Flex Robots, is a fully automated thermoelectric module and integrated for use with the Opentrons platform. It is used to achieve temperature changes ranging from 4 to 95°C for various applications.
The Temperature Module GEN2 is compatible with the new Opentrons Flex Robot when paired with the Flex Temperature Caddy and Calibration Adapter. The caddy sits below the deck to enable below-deck cable routing and labware placed on modules remain closer to the deck surface. The calibration adapter is used to calibrate the location of the module. If you choose to include the Opentrons Flex Caddy and Calibration Adapter, your order will ship in 20 business days.
Sulfo DBCO-TFP Ester is a water-soluble, amine-reactive labeling reagent that enables simple and efficient incorporation of Sulfo DBCO moiety onto amine-containing molecules. The hydrophilic, sulfonated spacer arm greatly improves water solubility of DBCO derivatized molecules, in many cases making them completely soluble in aqueous media. A short spacer arm adds minimal mass to modified molecules.
Document
Sulfo DBCO-TFP Ester is a water-soluble, amine-reactive labeling reagent that enables simple and efficient incorporation of Sulfo DBCO moiety onto amine-containing molecules. The hydrophilic, sulfonated spacer arm greatly improves water solubility of DBCO derivatized molecules, in many cases making them completely soluble in aqueous media. A short spacer arm adds minimal mass to modified molecules.