The BK virus is a member of the polyomavirus family. BK viral infections are typically asymptomatic in healthy individuals, however very mild symptoms may appear including mild respiratory infections and fever. Once an individual has been infected the virus disseminates to the kidneys and the urinary tract where it remains for the lifetime of the individual. Infections with BK virus in immunocompromised or immunosupressed patients are much more severe and may involve renal dysfunction. In fact, in kidney transplant patients the immunosupressive drugs required for the transplant may allow the virus to replicate within the graft, resulting in a disease called BK virus nephropathy (BKVN). It is thought that 1-10% of renal transplant patients progress to BK virus nephropathy (BKVN) and up to 80% of these patients are reported to have lost their grafts. The onset of nephritis can occur as early as several days post-transplant to as late as 5 years. The mode of transmission of the virus is not clear, however it has been suggested that BKV may be transmitted through respiratory fluids or urine, since infected individuals periodically excrete virus in the urine. This virus can be diagnosed by BKV blood & urine testing, in addition to carrying out a biopsy in the kidneys. PCR techniques are now widely used to identify the virus.
BKV TaqMan PCR Kit, 100 reactions
BKV TaqMan PCR Probe/Primer Set and Controls, 100 reactions
For research use only and NOT intended for in vitro diagnostics.
Figure 1 / 3
Click for expanded view
Storage Conditions and Product Stability
All kit components can be stored for 2 years after the date of production without showing any reduction in performance.
All kit components should be stored at -20°C upon arrival. Repeated thawing and freezing (> 2 x) of the Master Mix and Positive Control should be avoided, as this may affect the performance of the assay. If the reagents are to be used only intermittently, they should be frozen in aliquots.
Component | Cat. TM36550 (100 preps) | Cat. TM36510 (100 preps) |
---|---|---|
MDx TaqMan 2X PCR Master Mix | 2 x 700 μL | – |
BKV Primer & Probe Mix | 280 μL | 280 μL |
BKV Positive Control | 150 μL | 150 μL |
Nuclease-Free Water (Negative Control) | 1.25 mL | 1.25 mL |
Product Insert | 1 | 1 |
K-GLUT
SKU: 700004301
60 assays (manual) / 600 assays (microplate) / 700 assays (auto-analyser)
Content: | 60 assays (manual) / 600 assays (microplate) / 700 assays (auto-analyser) |
Shipping Temperature: | Ambient |
Storage Temperature: | Short term stability: 2-8oC, Long term stability: See individual component labels |
Stability: | > 1 year under recommended storage conditions |
Analyte: | L-Glutamic Acid, MSG |
Assay Format: | Spectrophotometer, Microplate, Auto-analyser |
Detection Method: | Absorbance |
Wavelength (nm): | 492 |
Signal Response: | Increase |
Linear Range: | 0.4 to 20 µg of L-glutamic acid per assay |
Limit of Detection: | 0.21 mg/L |
Reaction Time (min): | ~ 8 min |
Application examples: | Fruit and vegetables (e.g. tomato), processed fruit and vegetables (e.g. tomato puree / juice, ketchup, soy sauce), condiments, processed meat products (e.g. extracts, bouillon and sausages), soup, pharmaceuticals and other materials (e.g. biological cultures, samples, etc.). |
Method recognition: | Methods based on this principle have been accepted by ISO, GOST and NMKL |
The L-Glutamic Acid test kit is a simple, reliable, rapid and accurate method for the measurement and analysis of L-glutamate (MSG) in foodstuffs.
Note for Content: The number of manual tests per kit can be doubled if all volumes are halved. This can be readily accommodated using the MegaQuantTM Wave Spectrophotometer (D-MQWAVE).
Explore more organic acid test kits.
Advantages
The L-Glutamic Acid test kit is a simple, reliable, rapid and accurate method for the measurement and analysis of L-glutamate (MSG) in foodstuffs.
Adenoviral vectors are useful tools for both in vitro and in vivo gene transfer, and oncolytic viruses based on adenovirus are highly promising for cancer treatment. Norgen’s Adenovirus Purification Kit provides a fast and simple procedure for concentrating and purifying adenoviral vectors from cell lysate and cell culture media. Purification is based on spin column chromatography using Norgen’s proprietary resin as an ion exchanger. Contaminating cellular debris is largely removed from the sample via a centrifugation step, while contaminating DNA and RNA is reduced using enzymatic digestion. Adenoviral vectors purified in this manner are highly active for use in transduction experiments.
Norgen’s Adenovirus Purification Kit contains sufficient materials for 15 preparations (33.5 mL per prep of supernatant or a total of 500 mL of supernatant input). Approximately 1 mL of cell pellet can be purified per prep, up to a maximum of 15 mL of cell pellet in total for the entire kit.
Figure 1 / 3
Click for expanded view
Kit Specifications | |
Resin Binding Capacity (total per kit) | At least 3×1011 adenovirus particles as determined by qPCR At least 3×108 transducing units as determined by transduction assay |
Input type | Cells, media |
Input volume (Supernatant) | 1 – 33.5 mL SN per prep (500 mL SN in total) |
Input Volume (Cell pellet) | 1 mL cell pellet per prep (15 mL in total) |
Minimum elution volume | 1.3 mL per prep |
Time to complete purification | 2.5 to 4.5 hours with 1 hour hands on time |
In vivo transduction | Yes |
Storage Conditions and Product Stability
HL-SAN Nuclease should be stored at -20°C upon arrival. Elution Buffer P should be stored tightly capped at 4°C upon arrival. All other solutions should be kept tightly sealed and stored at room temperature. This kit is stable for 2 years after the date of shipment.
Component | Cat. 67600 (15 preps) |
---|---|
Lysis Buffer S | 5.5 mL |
HL-SAN Nuclease | 102 µL |
Binding Buffer A | 20 mL |
Purification Solution C | 60 mL |
Purification Solution D | 130 mL |
Wash Solution C | 2 x 130 mL |
Slurry E | 12.5 mL |
Elution Buffer P (store at 4°C) | 66 mL |
Protein Neutralizer | 4 mL |
Elution tubes (1.7 mL) | 50 |
Product Insert | 1 |
83, On-nut 88/2 Prawet Sub-district, Prawet District, Bangkok, 10250, Thailand
Tel : 081-875-1869 , 02-328-7179
Email : hej@a3p-scientific.com
Copyright © 2024 A3P Scientific Co., Ltd. All rights reserved. Web by Mountain Studio
Privacy Policy | Terms of Use | Site Map